Welcome Customer !

Membership

Help

Guangzhou Hangxin Scientific Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Guangzhou Hangxin Scientific Instrument Co., Ltd

  • E-mail

  • Phone

  • Address

    807, No.12 Dekang Road, Tongdewei, Baiyun District, Guangzhou City

Contact Now

NAI-HL6S Fully Automatic Water Bath Reflux Extraction Instrument for Pre condensation Treatment

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The pre-treatment device of NAI-HL6S fully automatic water bath reflux extractor (NAI-HL6S) can be used for the hydrolysis, saponification, and methylation of samples in the pre-treatment of fatty acid determination samples. It can process 6 samples simultaneously and is equipped with a hot and cold dual water bath. The condenser reflux device automatically lifts and lowers for easy sample replacement. The magnetic visual mixing function of Jian Ge easily completes sample hydrolysis. Solved the problems of complex operation and messy laboratory in the traditional pre-treatment of fatty acid determination. Suitable for the determination of fatty acids in food, grain and oil, milk powder and other products. During the experiment, the sample inside the evaporation bottle will be heated and evaporated in a water bath.

Product Details

638191547986446588552.jpg

NAI-HL6S Fully Automatic Water Bath Reflux Extraction Instrument Pre treatment Device

The fully automatic condensation reflux extractor (NAI-HL6S) can be used for sample hydrolysis, saponification, and methylation in the pre-treatment of fatty acid determination samples. It can process 6 samples simultaneously and is equipped with a hot and cold dual water bath. The condenser reflux device automatically lifts and lowers for easy sample replacement. The magnetic visual mixing function of Jian Ge easily completes sample hydrolysis. Solved the problems of complex operation and messy laboratory in the traditional pre-treatment of fatty acid determination. Suitable for the determination of fatty acids in food, grain and oil, milk powder and other products. During the experiment, the sample inside the evaporation bottle will be heated and evaporated in a water bath. The steam enters the condenser reflux device above the evaporator, where there is a low-temperature circulating liquid in the condenser tube. When the steam encounters the low-temperature condenser tube, it is liquefied and refluxed back into the evaporator bottle, and this process repeats. The evaporation reflux stage is completed during the distillation process. The evaporation bottle can be removed and placed in a low-temperature water bath, and the sample will be quickly cooled to room temperature.


Applicable standard(Only partially displayed)

The determination method of extracts in the Chinese Pharmacopoeia includes alcohol soluble hot soaking method, fat and fat oil determination method, and traditional Chinese medicine extraction reflux method
National Food Safety Standard - Determination of Starch Total Acid, Vitamin A, D, E Fatty Acids in Food
GB 31604.5-2016 National Food Safety Standard Determination of Extracts in Resin of Food Contact Materials and Products
GB/T 5009.127-2003 Determination of Germanium in Polyester Resin and Its Shaped Products for Food Packaging
GB/T 8021-2003 Petroleum products Determination of saponification value
GB/T 10345-2022 Analytical Method for Baijiu (Determination of Total Esters and Esters)
Soil Analysis Technical Specification - Determination of Boron in Soil by Imine-H Colorimetric Method (Boron Extraction Reflux Device - Quartz Condensation Reflux Extraction Instrument)

Main features

1. The instrument body adopts a frame integrated design, which is stable and reliable. The main body is made of 1mm thick brand cold-rolled plate with electrostatic powder coating, which is more wear-resistant and corrosion-resistant;
2. From air to contacts, relay protectors to button switches, etc., use Chint/Delixi or equivalent electrical brands to ensure instrument quality and service life;
3. Adopting PLC system control, the performance is more stable. The 7-inch touch screen can freely set experimental parameters such as heating temperature, time, magnetic stirring, and sample lifting;
4. A dual water bath design with hot and cold water baths, where the cold water bath can quickly cool the sample to room temperature; The hot water bath is equipped with sensors for real-time monitoring, providing more accurate temperature control;
5. The motor controls the condenser and sample to move up and down automatically, and the hot water bath ends with automatic lifting, without the need for personnel intervention throughout the entire process;
6. Hot water bath with automatic water inlet, automatic drainage, automatic alarm for water shortage and replenishment, internal circulation high-temperature circulation pump, uniform and constant temperature, single-stage temperature control, supports five stage program temperature control, with temperature curve;
7. Intermittent magnetic stirring, single channel single control, stepless speed regulation, eliminating the tedious operation of manually shaking samples at regular intervals;
8. Configure a dedicated external chiller to save water, with a temperature as low as 5 ℃, suitable for various national standard condensing tube temperature requirements, and better condensing reflux effect;
9. The system comes with an instruction manual and a QR code for the service center. Scanning the code with your phone will automatically view the electronic instruction manual and provide a one click link to the service center.


Technical specifications

Product Model NAI-HL6S
control system PLC+7-inch touch screen
Electrical Manufacturing Standards Chint/Delixi
Heating method Built in high-temperature circulation pump, water bath temperature is uniform and constant
Temperature control method Single stage temperature control, supports five stage program temperature control, with temperature curve
Hot water bath control Automatic water intake, automatic drainage, automatic water shortage alarm and replenishment
Cold water bath control 5 ° (lowest)
condenser tube Spherical condenser tube (40mm) with spiral mouth
Liquid inlet There is a liquid inlet in the middle of the condenser tube
time control 0-999min
Temperature measurement method 2-channel probe
heating unit 6 people
Heating the sample Standard 250ml round flat bottomed flask
Lift function Yes (travel 150mm)
Sample cooling fan 3-digit high-power
Plastic trap cover plate 6 of them
Standard chiller CW5300 (10 liters, 2.3KW cooling capacity)
magnetic stirring
Yes (single channel single control, intermittent)
Empty switch protection have
Total machine power 2500W
rated voltage 220V/50HZ

NAI-HL6S Fully Automatic Water Bath Reflux Extraction Instrument Pre treatment Device