Multi functional smoke tester

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Multi functional smoke tester: The height of the detection rod should not be less than 2.5m, equipped with a smoke hood and a built-in power cord; Continuous working time not less than 2 hours, temperature detector function tester: detection rod height not less than 2.5m, built-in power cord; Continuous working time not less than 2 hours

Product Details

  
Firefighting technical service institutions' employment conditions, testing instruments and equipment, maintenance and testing equipment boxes for firefighting facilities Fire technology service instruments and equipment Fire safety assessment equipment and instruments
The VC12X fire protection technology service equipment box and fire protection facility maintenance and testing equipment box are provided by Beijing Xinyu Shengli Instrument Co., Ltd. in accordance with the "Employment Conditions for Fire Protection Technology Service Institutions" GA1157-2014 Equipment Allocation for Fire Protection Technical Service Institutions A portable fire detection instrument box has been developed and launched in accordance with the "GA503-2004 Technical Regulations for Testing Building Fire Protection Facilities". It is a collection of fire detection instruments and commonly used measuring tools for detecting and maintaining fire automatic alarm and control systems, fire hydrant systems, automatic sprinkler systems, smoke and exhaust systems, fire emergency lighting systems, and other commonly used fire extinguishing systems.
The design and selection of VC12X fire protection technology service equipment box and fire protection facility maintenance and testing equipment box are reasonable, and the equipment configuration is complete and meets the standards. It can meet the measurement calibration requirements of national legal measurement and testing units, is easy to master, easy to operate, and suitable for on-site use. Suitable for fire technology service institutions to inspect building fire protection facilities, maintain and upkeep building fire protection facilities, conduct fire inspection and acceptance by housing and construction departments, supervise and accept the use of construction project fire protection, conduct user self inspection and project supervision, etc., it realizes the evaluation of whether the fixed fire extinguishing system can truly play a role under fire conditions based on technical data. All devices are current * products.
VC12X fire protection technology service equipment box, fire protection facility maintenance and inspection box equipped with: stopwatch; Tape measure; Vernier caliper; Steel ruler; Square ruler; Electronic scale; Dynamometer; LED flashlight; Laser range finder; Digital illuminance meter; Digital sound level meter; Digital anemometer; Digital micro pressure gauge; Digital temperature and humidity meter; Ultrasonic flowmeter; Digital slope meter; Verticality measuring instrument; Fire hydrant pressure measuring joint; Water spray end test joint; Grounding resistance measuring instrument; Insulation resistance measuring instrument; Digital multimeter; Smoke detector function tester; Temperature detector function tester; Linear beam smoke detector filter; Flame detector function tester; Leakage current detector; Portable combustible gas detector; Digital pressure gauge; Fine water mist end water testing device; Operation manual, fire detection instrument box, etc;
Equipment for fire safety assessment: computer; Evaluation software [personnel evacuation capability simulation analysis software, smoke flow simulation analysis software (CFD), structural safety calculation analysis software, etc.]; Smoke analyzer; Smoke density meter; Radiant heat flux meter.
Other optional equipment: explosion-proof electrostatic voltmeter; Ultrasonic leak detector; Fireproof coating thickness gauge, infrared thermometer, infrared thermal imager, ultrasonic detector, handheld pump speed detector, portable ultrasonic steel cylinder level gauge, residual current tester, residual current generator, VC12 building fire protection facility detection box, VC12F construction project fire acceptance inspection box; Maintenance and upkeep equipment for building fire protection facilities; Fire protection equipment testing instruments and equipment; Fire electrical testing instruments; Fire safety assessment consulting equipment; Gas fire extinguishing system detection equipment; Building fire detection box; Fire automatic alarm system detection equipment, automatic sprinkler system nozzle installation tools, fire hydrants and smoke control and exhaust system inspection and testing equipment, and quality inspection equipment.