Multi functional radiation detectorIt can be widely used in pharmaceutical factories, laboratories, power plants, quarries, emergency rescue stations, metal processing plants, oil fields and oil pipeline equipment, environmental protection and other departments. Can be used for:
Check groundwater,Radium pollution
Check the radioactivity of underground drilling pipes and equipment
Check for radon radiation and cesium pollution in the surrounding environment
Check the radioactivity of building materials such as stone
Check the radioactivity of porcelain tableware, glass cups, etc
Check for local radiation leaks and nuclear radiation contamination
Inspect landfills and garbage dumps with nuclear radiation hazards
Inspect personal valuable assets and jewelry for harmful radiation
Testing from Medical to IndustrialXThe X-ray instrumentXRadiation intensity
Measure the type of radiation |
alphaTheB、γandΧray |
measurement range |
Radiation dose rate:0.01µSv/h-1000µSv/h Pulse dose rate:0-300,000cpm,0-5,000cps Cumulative value of radiation dose:0.001µSv-999999Sv Cumulative value of pulse dose:0-999999 |
sensitivity |
1µSv/h≥2cps(Cs137) |
Energy response |
50keV - 3MeV |
Ray selection switch |
toalphaTheB、γandxCombination selection of rays |
sensor |
Small end windowGMpipe |
Stability of background value |
±0.02µSv/h(8Hour) |
output port |
USBComputer connection port (dedicated)USBThe extension line is optional and can be extended up to100Rice) |
Anti saturation |
Exceeding the maximum reading100In multiple occasions, keep the reading at full scale |
display |
large screen4Digit numberLCD, with stick chart display |
correction |
Directly adjustable correction factor |
alarm function |
Sound and light alarm, freely adjustable alarm value, default setting is5μSv/h |
precision |
±15% |
Storage function |
Manual or automatic storage |
software |
Real time remote transmission of numerical values to a computer for display, analysis, and recording |
External electromagnetic wave influence |
negligible |
10Double the influence of geomagnetic field |
none |
Operating Temperature |
-10℃to+ 60℃ |
Storage temperature |
-20℃to+ 75℃ |
Working atmospheric pressure |
75kPa-110kPa |