Mining control cable MKVV 2 * 0.75
Control cables for coal mines:
1. PVC insulated PVC sheathed control cable (MKVV) for coal mines
2. PVC insulated PVC sheathed armored control cable for coal mines (MKVV22)
3. PVC insulated PVC sheathed braided shielded control cable (MKVVP) for coal mines
4. PVC insulated PVC sheathed braided shielded steel tape armored control cable for coal mines (MKVVP22)
5. Control cable with PVC insulation, PVC sheath, fine steel wire armor for coal mines (MKVV32)
6. PVC insulated PVC sheathed control flexible cable for coal mines (MKVVR)
Control cables for coal mines, MKVVP plastic control cables for coal mines, MKVV22 plastic insulated cables for coal mines
Execution standard: Enterprise standard Q/TX001-2006 This standard is applicable to copper core PVC sheathed flame-retardant control cables used in coal mines.
Mining control cable MKVV 2 * 0.75
MKVV cable, MKVVP cable, MKVVP2 cable, MKVV22 cable, MKVV32 cable, MKVVR cable, MKVVRP cable, MKVVP22 cable and other specifications and models of flame-retardant control cables for coal mines, with cable cores of 2,3,4,5,7,8,10,12,14,16,19,24,27,30,37,44,48,52,61
MKVV(2-14)*(4-6)mm2 ,(2-10)*10mm2 (2-61)*(0.75-2.5)mm2 MKVV22(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2 MKVVP(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2 MKVVP22(7-61)*(0.75-1.5)mm2 (4-61)*2.5mm2 (4-14)*(4-6)mm2
Mining control cable models: MKVV, MKVV22, MKVV32, MKVVR, MKVVP, MKVVRP, etc. Detailed description: 1. Mining flame-retardant control cables have excellent flame-retardant properties compared to general control cables. Meets the flame retardant performance requirements of MT818 coal mine flame retardant cables and MT386. 2. Scope of application: Control cables are suitable for control, monitoring circuits, and protection lines with AC rated voltage of 450/750V and below. Characteristics of use of control cables: 1. The conductor's long-term allowable working temperature is 70 ℃. 2. The ambient temperature during installation is ≥ 0 ℃. 3. Small bending radius: 4. For unarmored cables, it should not be less than 6 times the outer diameter of the cable. 5. Cables with armored or copper tape shielding structures should not be less than 12 times the outer diameter of the cable. 6. Flexible cables with shielding structures should not be less than 6 times the outer diameter of the cable
Note: The recommended core series are: 2, 3, 4, 5, 6, 7, 8, 10, 12, 14, 16, 19, 24, 30, 44, 48, 52, and 61 cores
1. Rated voltage 450/750v
2. The length of the cable conductor allows for a working temperature of 70 degrees Celsius
3. The laying temperature of the cable should not be lower than 0 degrees Celsius, and the allowable bending radius should be selected;
4. The cable without armor layer should not be less than 6 times the outer diameter of the cable
5. Cables with armor or copper tape shielding structures should not be less than 12 times the outer diameter of the cable.
6. Flexible cables with shielding structures should not be less than 6 times the outer diameter of the cable.