ü Can measure the horizontal plane of objects in a can ü Can detect dust ü Can detect all dust like objects, such as sand, gypsum, sawdust/process wood chips, cement, coal/brown coke powder, flour, calcium carbonate powder, talc powder, crushed stone, lime powder, limestone powder... ü Can measure free fall conveying methods ü Can measure air conveying methods ü ATEX type ü Can measure flow rates from 0.5kg/hour to several tons per hour ü Can measure both horizontal and vertical conveying methods ü Can adapt to changes in concentration and particle size EDITFLOW microwave solid flowmeter Main working principle: Microwave probe emits a 24.125GHz signal at a power of 5mw When an object passes through the high-frequency microwave signal, it will form a reflection on the microwave signal. The host will calculate the actual flow rate of the measured object based on the changes in the emitted and reflected microwave signals, and display the value on the host. This value can be directly sent to the monitoring center located at the headquarters in France through a remote monitoring system for manufacturers to analyze the data and remotely calibrate and debug the equipment when it issues an abnormal data alarm. Composition and Technical Parameters of EDITLOW Microwave Solid Flow Meter System: The EDITLOW microwave flow meter system includes: microwave probe (signal transmitter), mounting bracket, dedicated data line, touch screen human-machine interface, voltage transformation system, continuous data storage, remote analysis and calibration device, silencing device (dedicated for low current measurement), EDITLOW microwave probe (signal transmitter), technical parameters: working voltage: 24V/DC ± 10%, working current: ≤ 450mA signal .....
Product Details
Product Introduction

Application areas and composition of EDITLOW microwave solid flow meter:
The EDITLOW microwave online flow detection system is used to measure the flow rate of solid powder materials in metallurgy, food (including feed), wood, paper processing, building materials, chemical industry, mining, pharmaceuticals, energy and other fields. This system includes a microwave probe and a touchscreen host controller.


The main application range of EDITLOW microwave solid flowmeter is: it can detect the flow rate of powdered objects, test whether there are objects passing through, and determine whether objects are flowing

ü Can measure the horizontal plane of objects in a can shaped container ü Can detect dust
ü Can detect all dust like objects, such as sand, gypsum, sawdust/craft wood chips, cement, coal/brown coke powder, flour, calcium carbonate powder, talc powder, crushed stone, lime powder, limestone powder
ü Can measure the free fall transport method ü Can measure the air transport method ü ATEX type
The measurement flow range can range from 0.5kg/hour to several tons per hour. It can measure both horizontal and vertical transport modes and adapt to changes in concentration and particle size

The main working principle of EDITLOW microwave solid flow meter is:
The microwave probe emits a high-frequency microwave signal of 24.125GHz at a power of 5mw. When an object passes through, it will reflect the microwave signal. The host will calculate the actual flow rate of the measured object based on the changes in the emitted and reflected microwave signals, and display the value on the host. This value can be directly sent to the monitoring center located at the headquarters in France through a remote monitoring system for manufacturers to analyze the data and remotely calibrate and debug the equipment when an abnormal data alarm is issued.

Composition and Technical Parameters of EDITLOW Microwave Solid Flow Meter System:
EDITFLOW
The microwave flow system includes:
♦ Microwave probe (signal transmitter) ♦ Installation bracket ♦ Dedicated data cable
♦ Touch screen human-machine interface ♦ Transformer system ♦ Continuous data storage
♦ Remote analysis calibration device ♦ Silencing device (dedicated for low flow measurement)
EDITFLOW
Technical parameters of microwave probe (signal transmitter):
♦ Working voltage: 24V/DC ± 10% ♦ Working current: ≤ 450mA ♦ Signal output: 4-20mA
♦ Usage environment: Outside the pipeline -10 ℃ -+55 ℃, inside the pipeline -10 ℃ -+60 ℃ (can be increased to+100 ℃ according to customer needs)
♦ Internal pressure: 100mBar (can be increased) ♦ Shell protection level: IP65
♦ Shell material: aluminum alloy and stainless steel
♦ Dimensions: 185mm * 115mm * 90mm ♦ Measurement accuracy: 1%

EDITLOW Microwave Solid Flow Meter Product Model:

1. The EDIT FLOW solid flow meter generally includes sensors, electronic displays, and mounting brackets for measuring standard and ATEX types
2. The EDIT DUAL FLOW high flow measurement includes two or more sensors, one electronic display, and multiple brackets for both standard and ATEX types when the pipeline cross-section is greater than 200mm
3. The EDIT MINI FLOW low flow measurement includes: one sensor, one electronic display, and two mufflers for the standard and ATEX models when the flow rate of the measured object is low
4. The EDIT FLOW NO FLOW flow switch detects whether there is an object passing through, whether the pipeline is flowing, and measures the level of the object in the tank container. Standard and ATEX models include: sensors and mounting brackets

Installation of EDITLOW Solid Flow Meter: Maintenance of EDITLOW Solid Flow Meter Equipment:
The operation of the sensor is controlled by an electronic chip, without any mechanical movement of any components. If the sensor is installed after a thorough and meticulous measurement, it can withstand no mechanical impact. In summary, sensors do not require any necessary special maintenance, but when the sensing position drifts, the detection results need to be checked.

Example of application of coal injection in blast furnace:
EDIT microwave solid flowmeter for process control of coal powder entering the furnace