Michell SF82-TX Dew Point Meter

NegotiableUpdate on 05/12
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Michell SF82-TX dew point meter is a split type dew point meter from the British brand MICHELL. It is mainly used to measure the dew point and moisture content in gases, and is suitable for humidity monitoring in compressed air, lithium batteries, and other scenarios.

Product Details

Michell SF82-TX Dew Point MeterMICHELL brand from the UKofSplit dew point meter, mainly used for measuring dew point and moisture content in gases, suitable forcompressed airLithium batteryWaiting for humidity monitoring in the scene. ‌

Core characteristics of Michell SF82-TX dew point meter

  • high-precision measurementLow dew point error and excellent accuracy

  • quick responseFast response speed and short recovery time

  • Design small and compactLightweight in size, easy to install and maintain

  • Strong compatibilitySupports analog/digital output and can be connected to various electronic controllers

SF82 MiniDIN 43650 C SF82 M12
performance parameters
measurement range -Dew point at 60 ° C~+60 ° C
precision ± 2 ° C dew point*
response time 63% @ room temperature @ 1 bara
-Dew point: 6 seconds from 60 ° C to -20 ° C
-Dew point: 40 seconds from 20 ° C to -60 ° C
reproducibility Dew point at 0.5 ° C
calibration Traceability standards
Electrical parameters
output signal Users can configure within the range; 4-20 mA
(2-wire connection, current source)
Users can configure within the range; 4-20 mA (2-wire connection, current source)
Modbus RTU Digital Communication Based on RS485
Humidity output Dew point or moisture content
temperature output Unavailable Data transmitted through Modbus RTU
Scalable range of analog output
4-20 mA (dew point)
-Dew point at 60 ° C~+60 ° C
-Dew point at 50 ° C~+50 ° C
-Dew point at 50 ° C~+30 ° C
-Dew point at 80 ° C~+20 ° C
-Dew point at 20 ° C~+50 ° C
(Non standard range can be provided upon request)
Scalable range of analog output
4-20 mA (moisture content in gas)
0 ~ 24000 ppmv
(Non standard range can be provided upon request)
power supply voltage 6.5~ 28 V DC 5 ~ 28 V DC
load resistor Maximum 250 Ω @ 12 V (500 Ω @ 24 V)
current Maximum 23 mA Analog maximum 23 mA, digital maximum 6 mA
Electrical safety IEC61010-1, UL61010-1 & CAN/CSA C22.2 No. 61010 IEC61010-1, UL61010-1 & CAN/CSA C22.2 No. 61010
EN61373 Rail Vehicles
EN50121-3-2 Railway Application EMC/RFI
working conditions
Operating Temperature -20 °C ~ +60 °C
Temperature compensation range -20 °C ~ +50 °C
Storage temperature -40 °C ~ +60 °C
Maximum work pressure 最大 10 MPag (100 barg)
Pressure safety level 最大 45 MPag (450 barg)
Traffic rate 1~5 Nl/min installed in a standard sampling sleeve; 0~10 m/sec direct insertion
mechanical parameters
Protection level IP66 complies with BS EN 60529
(Current version);
NEMA 4 protection level meets
NEMA 250 (current version)
IP65
Shell material 316 stainless steel
size L=133 mm x ø 45 mm (with connector cable) L=156 mm x ø 45 mm (with connector cable)
Filter (sensor protection) Standard: HMWPE<10 μ m Optional: 316 stainless steel sintering protection<80 μ m
process connection 5/8” 18 UNF
3/4” 16 UNF
G1/2” BSP
weight 150 g (excluding connector cables)
electrical connection MiniDIN 43650 Type C M12 5-pin (code A)
Electrical connection accessories Standard Accessories
Optional 0.8, 2, 5, 10 meter MiniDIN connectors/cables
Optional M12 A codes of 0.8, 2, 5, and 10 meters
Connector/Cable
analog output
Diagnostic conditions
(Factory setup)
Sensor malfunction: 23 mA
Below the dew point lower limit: mA
Above dew point limit: mA
Note: * Overcompensation temperature range

Applicable scenarios

  • Industrial gas humidity monitoring (such as air compressors, refrigerated dryers)