MY100 diffusion silicon differential pressure transmitter

NegotiableUpdate on 05/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The MY100 diffusion silicon differential pressure transmitter is used to measure small differential pressures such as furnace pressure and gauge pressure, and then convert them into 4-20mA DC signal output.

Product Details

MY100 diffusion silicon differential pressure transmitterUsed to measure small differential pressures such as furnace pressure and gauge pressure, and then convert them into 4-20mA DC signal output.GCECC-ZH differential pressure transmitterIt can also communicate with the HART handheld device for setting, monitoring, or forming an on-site monitoring system with the upper computer.

The MY100 diffusion silicon differential pressure transmitter, an on-site adjustable intelligent differential pressure transmitter, is a new product developed by our company according to on-site requirements,
It can be detached from the handheld device and operated through buttons to achieve on-site zeroing, configuration, and other operations.
1. Performance specifications
(Zero benchmark calibration range, under reference conditions, filled with silicone oil and 316 L stainless steel isolation diaphragm.). )
1.1. Reference accuracy
1.1.1. Digital and intelligent: ± 0.2% calibration range
1.1.2. Simulation, linear: ± 0.5% calibration range
1.2. stability
1.2.1. Digital and intelligent: 6 months, ± 0.2% URL
1.2.2. Simulation, linear: 6 months, ± 0.5% URL
1.3. Environmental temperature impact
1.3.1. Numbers and Intelligence:
Zero point error: ± 0.2% URL/56 ℃
Overall error: ± (0.2% URL+0.18% checksum)
Cheng)/56 ℃
1.3.2. Simulation, Linear
Zero point error: ± 0.5% URL/56 ℃
Overall error: ± (0.5% URL+0.5% checksum)
Cheng)/56 ℃
1.4. Static pressure influence
The zero point error is ± 0.5% URL. It can be corrected online by resetting the zero.
MY100 diffusion silicon differential pressure transmitter, wind pressure transmitter,