Low temperature biochemical incubator manufacturerProduct Features:
1. In line with the global trend of environmental protection, the brand new fluorine free design.
2. Large screen LCD display, multiple sets of data are operated together on the interface, simple and easy to understand, convenient for observation and operation.
3. Adopting a mirror stainless steel inner liner, with four semi-circular transitions at the corners, the partition bracket can be freely installed and removed, making it easy to clean the workshop.
4. There is a 30mm diameter test hole on the left side of the box, and a power socket is standard on the outside of the box, which can be wired according to the needs of the placement location.
5. Place the oscillator in the box to achieve constant temperature oscillation cultivation.
6. Fuzzy PID controller, with small temperature control fluctuations and timing function, the time can be set to 99 hours and 59 minutes.
7. The workspace is equipped with lighting fixtures for easy observation of experimental conditions in the studio.
8. Using branded compressors and circulating fans, the design concept of the circulating air duct ensures uniform temperature and humidity in the workshop, avoiding sample evaporation caused by excessive air volume during the experiment.
9. The door is equipped with a hollow tempered glass observation window for easy observation of the internal status of the instrument.
10. Optional features include internal humidification, 485 communication, USB interface, printer, and leakage protection.
Low temperature biochemical incubator manufacturerDaily maintenance work:
1. When the temperature is low, condensation water will be generated in the biochemical incubator. The accumulated water in the bottom water tray of the incubator should be regularly emptied.
2. When the biochemical incubator needs to be stopped, the power plug should be unplugged.
3. The indoor environment should be dry, well ventilated, and the relative humidity should be kept below 85%. There should be no corrosive substances present, and direct sunlight on the biochemical incubator should be avoided.
4. The power supply used must have a reliable grounding wire to ensure reliable contact between the ground wire of the biochemical incubator and the ground wire of the grid power supply, preventing harm caused by leakage or accidental use of the grid power supply.
5. When transporting biochemical incubators, care must be taken not to invert them up and down. They should be transported vertically, and the angle between the incubator and the horizontal plane should not be less than 45 °. Otherwise, it may cause damage to the refrigeration compressor inside the equipment or abnormal cooling performance.
6. In order to maintain the appearance of the biochemical incubator, acid, alkali, or other corrosive substances should not be used to wipe the surface of the incubator. The incubator can be regularly wiped dry with a dry cloth.
Low temperature biochemical incubatorparameter
| Product Model Model | Temperature control range Temperature range | Price (CNY) Price(RMB) | Power (KW) Rated power | Volume (L) Volume | Inner container dimensions: depth * width * height (mm) D * W * H |
| SpX-30B | o0-60°℃ | 4600 | 0.6 | 30 | 25ox300x350 |
| SPX-50B | 5000 | 0.8 | 50 | 300×400×400 | |
| SPX-80B | 5600 | 0.8 | 80 | 350×450×450 | |
| SPX-150B | 7000 | 0.9 | 150 | 400×500×730 | |
| SPX-250B | 8000 | 1 | 250 | 500×500×950 | |
| SPX-350B | 10000 | 1.2 | 350 | 500×600×1100 | |
| SPX-460B | 14000 | 1.4 | 460 | 650x650x1100 | |
| SPX-560B | 18000 | 1.6 | 560 | 650x750x1150 | |
| SPX-660B | 21000 | 1.8 | 660 | 650x850x1200 |