Welcome Customer !

Membership

Help

Shanghai Yifeng Precision Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Leetes WL8A pro high-precision direct reading spectrometer

NegotiableUpdate on 01/04
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Leetes WL8A pro high-precision direct reading spectrometer brand: Leetes model: WL8A pro manufacturer: Guiyang Leetes Instrument Co., Ltd. detector: photomultiplier tube (PMT) light source full frequency digital spark excitation light source, ensuring the stability of the light source. High analysis accuracy. The spark holder is protected by argon filling. Discharge dual pulse adjustable: 1us ---200us (software control programmable) Inductance: 20H, 50H, 100uH Frequency: 100-1000Hz Continuous adjustable (software control programmable) Discharge voltage: 100V, 200V, 300V Controllable
Product Details
  • readout system

  • Ultra high speed digital collector,1 million times per second, using multiple segmented integration method and single spark signal acquisition.

  • 16 bit A/D converter, capable of high-speed sampling at 100kHz per second to ensure acquisition accuracy.

  • Pre digital control, standard industrialUSB interface. Very convenient to connect with standard computers.

  • Read system accuracy:RSD≤0.01%

  • Equipped with fault diagnosis functions for various parts of the instrument, and fully connected in ChineseWindows analysis software can automatically complete fault diagnosis.

  • detectorAdopting JapanHamamatsu photomultiplier tube

  • optical system

  • BaxingDragon grid method, independent suspension vacuum system with grating focal length of 750mm.

  • Wavelength range:λ150nm-800nm

  • GermanyZeiss grating engraving line: 2400g/mm focal length: 750mm dazzling wavelength: 190nm

  • base channel10 of them. (Up to 64 channels)

  • Photomultiplier tube high voltage1000V stability 0.01% (load variation 100%)

  • Special processing techniques10um -70um independently adjustable shooting slit. The accuracy is very precise.

  • sample stage

  • The size of the spark table is110 X 75mm

  • The discharge chamber is specially designed to facilitate excitation and save argon gas.

  • Enclosed spark chamber design to avoid injury to personnel caused by spark radiation.

  • The excitation electrode is a tungsten electrode or a silver electrode.

  • analyzesoftware

  • All in ChineseRun analysis software on Windows, set analysis spark parameters, select excitation, flushing, and pre ignition explosion time, and automatically complete

  • Automatic data collection. The least squares principle automatically fits the working curve.

  • Automatic two-point or single point standardization of analysis curves

  • Automatic sample control calibration, one analysis curve, can choose multi-point sample control calibration.

  • Output methods available: intensity, intensity ratio, concentration, correction concentration

  • At the same point, it is possible to repeat one or more excitations, and delete the results of one or more excitations

  • Automatically calculate the average value,SD and RSD

  • Correction of interference between elements and background correction

  • Common standard substance library

  • The test results can be printed out and saved in a disk. The printing format can be arranged by oneself. It can also be generatedWord documents, etc. Save it.

  • The test results can be transmitted over long distances through networks and computer standard ports.

  • The software comes with fault diagnosis and self-test programs. The automatically generated data file can be used to remotely diagnose instrument malfunctions.