The ATH8010 Laboratory Flat Scan Hyperspectral Imager Analysis System is a high-resolution, high-definition, and high-quality laboratory flat scan hyperspectral imaging instrument launched by Aopu Tiancheng. It consists of a hyperspectral imaging instrument, a flat scan structure, a light source, an imaging camera, a data processing workstation, and other components.
Overview
ATH8010Laboratory flat scan hyperspectral imaging analysis systemyesA high-resolution, high-definition, and high-quality product launched by Aopu TianchengofLaboratory flat scanHyperspectral imaging instrument,Composed of hyperspectral imaging instrument, flat scan structure, light source, imaging camera, data processing workstation, etc.
ATH8010Laboratory flat scan hyperspectral imaging analysis systemadoptA high-performance CCD imaging device with 1920X1080 pixels, providing clear imaging and minimal noise;
ATH8010Combining hyperspectral imaging technology with high-definition photography technology, the collected data has both hyperspectral resolution and high spatial resolution, which can fully explore the spectral and spatial characteristics of the material itself. It can be applied to material sorting (tobacco, pharmaceuticals, food, minerals, etc.), criminal investigation and document inspection, authenticity identification and other fields.
The laboratory hyperspectral system consists of a hyperspectral imager, a line light source, a high-definition camera, a sample stage, a focusing device, and a standard whiteboard. The line light source is aligned with the line field of view of the hyperspectral imaging instrument, and data acquisition is achieved through the translation of the sample stage. The high-definition camera captures global high-definition images of the sample stage at zero position for image fusion with hyperspectral data to compensate for its insufficient spatial resolution. Standard whiteboards are used for reflectance correction on both spatial and temporal scales to improve data inversion accuracy. Enterprise experimental research equipment.
feature
Band range:400-1000nm
Automatic integration time recommendation, recommending exposure time based on sample reflectivity
Application field
lMedical institutions: cancer tissue screening, blood cell classification;
lResearch institutions, colleges and universities
lPharmaceutical companies: anti-counterfeiting of traditional Chinese medicinal materials
lFood safety: Meat source identification;
lTextile: Copying patterns, copying pictures
lMineral screening
lJudicial appraisal: document inspection appraisal
lBiology: Bacterial and Cellular Analysis
lMaterials Science: Microscopic Testing of Materials
lAgriculture: Leaf and tobacco scanning
lScanning and restoration of cultural relics, restoration of murals
Technical Specifications
| serial number |
indicator |
parameter |
Remarks |
| 1 |
spectral range |
400-1000nm |
|
| 2 |
spectral resolution |
Better than 2.5nm |
30um slit |
| 3 |
spatial resolution |
Better than 1mm |
Customizable, limited by instrument volume |
| 4 |
Number of spatial channels |
480 |
4-pixel merging |
| 5 |
Number of spectral channels |
270 |
4-pixel merging |
| 6 |
dynamic range |
12bit |
NA |
| 7 |
Field of view width |
210mm |
customizable |
| 8 |
scanning range |
0~280mm |
customizable |
| 9 |
Sample thickness |
0~50mm |
customizable |
| 10 |
Reflectance calibration board |
3%,50% |
customizable |
| 11 |
Visible light camera resolution |
24 million pixels |
replaceable |
Accessories List:
serial number |
item |
quantity |
optional |
1 |
microscopicHost of hyperspectral imaging instrument (400-1000nm) |
1 unit |
standard configuration |
3 |
Objective lens and radiometric calibration |
1 set |
standard configuration |
4 |
Hyperspectral imaging systemserviceWorkstation (including operation controller and control software) |
1 set |
standard configuration |
6 |
High blue steady flow halogen lamp |
4 of them |
standard configuration |
7 |
Standard calibration board |
1 piece |
standard configuration |
Effect Showcase
lSpace time radiation intensity correction significantly improves radiation calibration accuracy
lLine light source design, matching line field of view, improving light energy utilization efficiency
lAssist in focusing, adjust the lifting and lowering according to the thickness of the sample to ensure image clarity
lAutomatic integration time recommendation, recommending exposure time based on sample reflectivity
lAutomatic scanning, automatic completion of data collection
lIntegrate high-definition cameras to improve spatial resolution, making it easy to navigate through massive amounts of data by following the map