This system consists of a low-priced data collector and a fault analysis and equipment management software with * functions. It can not only determine the operating status of equipment through status data, but also diagnose and predict equipment failures through various spectral analyses. By using this system, not only can the operating status and development trend of the equipment be accurately grasped through the vibration trend curve, but also a series of equipment faults such as rotor imbalance, shaft misalignment, shaft bending, foundation looseness, oil film oscillation, bearing and gear faults can be accurately diagnosed.
[Laboratory Safety Management SystemFunction]
data collector:
1Full Chinese menu, large LCD display with backlight;
2Measure and display five state parameters: acceleration, velocity, displacement, temperature, and rotational speed;
3Built in vibration intensity standard, automatically identifying equipment operating status (good, careful, dangerous);
4Maintaining, storing, and replaying status data;
5Waveform data acquisition (with arbitrarily set acquisition conditions), storage, and playback of waveform data acquisition conditions;
6Multiple sets of data collection with arbitrary length, number of groups, and distance can be set for easy analysis of startup and shutdown faults;
7The collector provides an RS-232C interface, which can communicate stored data with a computer;
8Large storage capacity, capable of storing 1000 sets of status data and 100 sets of 512 point waveform data separately;
9Built in rechargeable battery, fully charged in 3 hours, can be used continuously for 8 hours.
Fault analysis and management software:
1A friendly all Chinese WINDOWS interface, flexible operation, and strong practicality;
2*Equipment management, data management, data printing, and data analysis functions;
3Support communication between data acquisition devices and computers, automatically generating nine types of device management and diagnosis.
Data report;
1Equipment status (good/cautious/dangerous) is automatically judged according to enterprise standards;
2Analyze the vibration trend of equipment at any time period and predict the operating status of the equipment;
3. Many moreSpectral analysis functions: time-domain analysis, amplitude spectrum, logarithmic spectrum, average spectrum, time three-dimensional spectrum, probability density spectrum, autocorrelation analysis, envelope analysis, and refinement analysis.
[Laboratory Safety Management SystemTechnical indicators
1Measurement range: Acceleration 0.1~199.9m/s2 (0-P) (10Hz~10KHz)
2Velocity 0.01-19.99cm/s (RMS) (10Hz-1KHz)
3Displacement 0.001-1.999mm (P-P) (10Hz-1KHz)
4Temperature range: 0 ℃ to 400 ℃
5Speed range of 1 to 60000 r/min
6Measurement accuracy: vibration 5% ± 2 words
7Temperature 1% ± 1 word
8Speed 2 ‰ ± 1 word
9Waveform acquisition: frequency lower limit 10Hz
10Frequency upper limit: 100 Hz~10KHz optional
11Sampling points: 512, 1024, 2048, 4096, 8192
12Group size range 1 to 100
13Continuous group spacing range~999.99 seconds
14Magnification automatic, 1, 2, 4, 8, 16, 32, 64, 128 times
15Dynamic range 72dB
16Storage capacity: 128Kbyte, capable of storing 1000 sets of status data and 100 sets of 512 points respectively
17waveform data
18Display: 128 × 64 dot matrix LCD, Chinese menu, with backlight
19Power supply: built-in rechargeable battery; External 5-9V DC power supply for power supply and charging
20、 体 积: 23.5cm×13cm×4.5cm
21Weight: 765 grams (including battery)