Labom temperature sensor GA2700 has arrived
Labom temperature sensorApplied to the food/pharmaceutical/biochemical industries,
Quick response, model series GA2700
Design features
Resistance thermometer used for directly measuring the temperature inside tanks or pipelines
■ Compact design
■ High precision
Measure resistance 1 × Pt100, 3-wire system*
Process connection methods suitable for the food/pharmaceutical/biochemical industries
Sanitary design and structural design comply with EHEDG standards
Quick response
M12 plug type electrical connection or outdoor object connection
■ Integrated transmitter
Explosion proof form: II 2G Eex ia IIC T4/T6
application
Mini resistance thermometers are particularly suitable for temperature monitoring, especially in the healthcare industry. The resistance changes with the measured temperature and can be sensed and converted into a signal by a transmitter. Due to its compact design, MiniTherm is widely applicable in the technological processes of food, pharmaceutical, and biochemical fields.
Technical data
Mechanical Design
The Pt100 resistor is directly integrated into the protective sleeve. Multiple process connection methods are available for selection
Protection type
IP67
electrical connection
Labom temperature sensor GA2700 has arrived
Model: GA2700
optional
Circular joint M12 with threaded connection, protection level IP67 in accordance with DIN EN 60529
Outdoor shell, threaded lid, stainless steel material. 4305, IP67
Temperature detection element
Protective sleeve Ø 6 mm
Optional: Diameter variation of Ø 4mm at the measuring end of the casing
Please refer to the selection table for the length
According to user requirements, static or dynamic application of protective casing calculations can be provided, and certificates can be provided
Flat PEEK insertion probe for temperature decoupling
Measure resistance
1 × Pt100, error meets *, meets DIN EN 60751, 4-wire connection
Working temperature
-50… 200℃
Labom temperature sensor process connection
Threaded connection G1/2 B DIN 3852
Conical thread, metal to metal joint
Tightening torque: M12 20Nm
G1/2 50Nm
. DIN11851, With spinning nut
The clamp connection complies with DIN 32676
The clamp connection complies with ISO 2852
. Tri Clamp
. Varivent
Excluding gaskets!
Other process connection methods as required
Work pressure
zui大16bar
Exception: Varivent D68 Code A1512
zui大10bar
Material
Liquid receiving parts made of stainless steel No. 1.4404
Surface quality
Surface roughness Ra ≤ 0.8 μ m
Welding<1.6 μ m
Can be electropolished according to requirements
Reaction time
Labom temperature sensor according to DIN EN 60751, the experimental process is flowing water (without transmitter)
Protective sleeve with a diameter of Ø 6: T90=5.5s
End variable diameter Ø 4 casing: T90=4.5s
Explosion proof certification
BVS 04 ATEX E 144 X
I 2G Eex ia IIC T4/T6
Ui ≤ 30V
Pi ≤ 200 mW
For other alternative intrinsic safety circuits, please refer to EN 60079
Transmitter
Can integrate appropriate Pt 100 transmitters:
Transmitter for outdoor shell top installation
Transmitter, model PA2430, for circular connector M12
LED on-site display
Programmable LED on-site display for stainless steel body (Ø 60 mm)
Keywords