Labom pressure transmitter - model: COMPACT, imported
Labom pressure transmitter - COMPACTDesign features
Labom pressure transmitter - COMPACTTechnical data
Shell design
design
Outdoor housing IP65 or IP67 with cable connectors
A right angle plug that complies with DIN EN 175301-803-A (DIN 43650, Form A), IP65
Cable connection, IP67
Circular connector M12, IP65
Connecting nut: Polyamide (with electrical plug or cable connection) with silicon seal for electrical components
The temperature impact within the relevant temperature range of 0... 50 ℃:
a) Shell - Zero point<0.2%/10 K fs
-Distance measurement<0.2%/10 K f.s
b) Process connection (diaphragm seal) according to design
Zero point error of flat packaging film box
DN25/ 1″ 4.8 mbar/10 K
DN32/ 1 1/2″ 2.3 mbar/10 K
DN40 1.6 mbar/10 K
DN50/ 2″ 0.6 mbar/10 K
Online membrane box zero point error
DN25/ 1″ 9.5 mbar/10 K
DN32/ 1 1/2″ 4.1 mbar/10 K
DN40 3.9 mbar/10 K
DN50/ 2″ 3.9 mbar/10 K
The zero point error of the listed process connections is a reference value for standard design. We can provide a detailed system calculation as requested. We can also provide diaphragm sealing systems with small errors.Labom pressure transmitter - model: COMPACT, imported
Auxiliary power supply
Standard design of pressure transmitter
·Nominal voltage 24V DC
Internal cavity ventilation is used for ranges<16 bar through shell threads or connecting cables (according to design)
Shell material: stainless steel
Process Connection
See the parameter values on the next page or order code
Material of casing: No. 1.4404 (316L)
Temperature range
Environmental temperature: -25... 70 ℃
Storage temperature: -40... 90 ℃
·Functional range 6... 30V DC
·Maximum allowable voltage 30V DC
Influence of power supply voltage
≤0.01% f.s. / V
Signal output
4…20mA, 2-wire circuit
Current limit of output signal
The maximum output current is about 30mA
Adjustment scope
Approximately ± 5% f.s. Zero point and distance measurement can be adjusted separately
Load
Standard design
UB=working voltage
Ra=maximum allowable load resistance (including wires)
Load impact
500 ohm load variation: ≤ 0.1% f. s
Safe operation
EN 61508, level compliant with SIL 2, T Ü V-Reg. - No. 44 207 1038 1144
Process temperature: see selection table
Range/Overload Limit
The intermediate range can be adjusted as required
Response time
≤20 ms
Measurement accuracy of pressure transmitter
Linear error includes hysteresis<0.2% f.s
(For ranges ≥ 0... 60bar, it is less than 0.3% f.s.)
Fixed point adjustment, with an adjustment accuracy of<± 0.2% fs
Explosion proof certification
CENELEC certification complies with ATEX Explosion proof Intrinsic Safety Government Testing Laboratory (T Ü V) 00ATEX 1557 X
. II 2G EEx ib IIC T6
. Umax ≤ 30V DC
. Imax ≤ 150 mA
. Pmax ≤ 1 W
. Ci ≤ 49 nF
Band Li ≤ 33 μH
Weight (without diaphragm seal)
Outdoor shell: approximately 460 g
Shell with connecting plug: approximately 200 g
Installation location
arbitrary
EMC testing
Noise interference complies with EN50082 Chapter 2, March 1995 edition, industrial standard
Radiation interference complies with EN50081 Chapter 1, 1993, residential and industrial area standards
The launching device itself is non radioactive
Keywords