E-mail
dan600507@163.com
-
Phone
19916557244
-
Address
Room 1706, International Trade Building, No. 55 Keelung Road, Waigaoqiao Free Trade Zone, Shanghai
Langbo China Technical Service Center, Germany
dan600507@163.com
19916557244
Room 1706, International Trade Building, No. 55 Keelung Road, Waigaoqiao Free Trade Zone, Shanghai
Labom Mini Thermistor Temperature Gauge: GA2700 Agent
Detailed Introduction
The Labom mini resistance thermometer is suitable for temperature monitoring and process control, mainly used for sterile measurement in the food and pharmaceutical industries. This resistance thermometer can be quickly and easily installed on all existing pipelines without the need for any modifications or welding. This thermometer can integrate a built-in temperature transmitter.
feature
■ Sanitary temperature measurement, not in contact with the medium,
Application pipeline diameter is 4... 57 mm
■ Measurement system acquisition
High precision and fast response
The jacket technology enables fast, efficient, and cost-effective installation of instruments
No need for welding, no need to interrupt the production process, no dead zone.
No need for additional isolation
Sanitary design and structural design comply with EHEDG standards
■ Measure resistance 1 × Pt100, three wire system*
■ Measurement range: -20 ℃ to a maximum of 160 ℃
The entire installation is stationary, and the plug-in measuring part can be disassembled, calibrated, and replaced
Explosion proof design: T? V 08ATEX 554093 X
■ Optional: Can integrate transmitter 4... 20 mA
Technical data of Labom mini resistance thermometer
Mechanical Design
The plug-in measuring element is equipped with a silver temperature probe that has a particularly fast response.
The probe maintains continuous pressure on the outer wall of the pipeline through a spring. The replaceable plug-in measuring part is therefore tightly attached to the surface of the outer tube wall, and the pressure of the spring is predefined and measured in advance. Because the insertion part is fixed in one installation position, all measurements are the same.
Electrical connection
optional
Cylindrical connection with M12 threaded plug
Outdoor shell and threaded cover, made of stainless steel 1.4305
Protection level IP67, compliant with DIN EN 60529
Pipe clamp
Labom Mini Thermistor Temperature Gauge: GA2700 Agent
Material: High performance heat-resistant plastic, integrated isolation system, hygienic design with an environmental temperature impact of approximately 0.2%/10K
Operating temperature: -20... 160 ℃
Protection level: IP 65
Plug in temperature detection component
Insertion measurement with a diameter of 6mm and hygienic design.
The measuring element is made of silver and temperature isolated by plastic. Insert the measuring part into the connector under spring pressure.
Please select a thermal conductive compound based on sample T6-030.
Measure resistance
Pt100, Compliant with *, DIN EN 60751, Three wire design and thin-layer technology.
Nominal size of pipeline
Labom Mini Thermistor Temperature GaugeApplicable to all standard nominal pipelines.
Please refer to the order selection table for detailed dimensions.
Explosion proof certification
T?V 08ATEX 554093 X
II 1 G Ex ia IIC T6/T5/T4
II 2 G Ex ib IIC T6/T5/T4
II 1 D Ex iaD 20 T89℃
II 2 D Ex ibD 21 T129℃
U1 ≤ 30 V
P1 ≤ 200 mW
C1 and L1 are extremely small and negligible
Reaction time
See Figure 1
Weight
With circular M12 connector:
The Conduit? ≤ 17.2 mm, approximately 100g
The Conduit? ≥ 18.0 mm, approximately 200g
Equipped with circular M12 connector and integrated transmitter:
The Conduit? ≤ 17.2 mm, approximately 130g
The Conduit? ≥ 18.0 mm, approximately 230g
With outdoor shell: approximately 400g
Integrated transmitter
Can integrate appropriate Pt100 transmitters:
a) Used for outdoor shell and meter installation of transmitters
b) Transmitter, model PA2430, suitable for circular connector M12
See product series T4
LED on-site indication
Programmable LED on-site indication, applied to stainless steel outdoor housing (? 60 slowly)
Refer to sample M6-031
For other models, please refer to the selection table or according to user requirements
Response time/accuracy
Example: Model GA2610, used for stainless steel pipes 13 × 1.5
Using thermal conductive compounds
process data
·Environmental temperature 20 ℃
·Medium: Water at 120 ℃
· V = 3 m/s
·Medium temperature: 120 ℃
·Model GA2610 Measurement temperature: 119.5 ℃
Response time τ 0.9 ≈ 6 seconds
Figure 1
The actual fluid temperature measurement is an equation that includes the following parameters:
·Thickness of pipe wall
·Thermal conduction between temperature probe and pipe wall
·Thermal conductivity of fluids
·Flow rate
·Environmental temperature
Design
size

wiring diagram
Selection Table - Please indicate other characteristics of models not listed-




Source keywords: