LD-CPC801H Intelligent Pressure Calibration Instrument

NegotiableUpdate on 05/15
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

LD-CPC801H Intelligent Pressure Calibration Instrument Product Overview: In addition to being used as a high-precision calibration standard (meter), it can also be used as a working instrument and is widely used in metallurgy, petroleum, chemical, power, natural gas, metrology, and scientific research departments.

Product Details

LD-CPC801H Intelligent Pressure Calibration InstrumentProduct Overview

In addition to being used as a high-precision calibration standard (meter), it can also be used as a working instrument and is widely used in metallurgy, petroleum, chemical, power, natural gas, metrology, and scientific research departments.

LD-CPC801H智能压力校验仪

LD-CPC801H Intelligent Pressure Calibration InstrumentTechnical indicators:
1. Range: -0.1~60 MPa (various levels)
2. Resolution: Pressure: Min 1Pa, Current: Min 1 μ A
3. Wide screen, 6-digit large characters, clear and intuitive
4. Accuracy: 0.05% F · S, Current: 0.05% ± 1d
5. DC output: 24V · DC
6. Environmental temperature: 5~50 ℃
7. DC working time: ≥ 40 hours
8. Display: 41/2LCD 51/2LCD
9. Relative humidity: ≤ 80% RH
10. Overload capacity: 1.2 to 1.5 times the upper range limit
11. Shell diameter: 110mm
12. Weight: 1kg
13. Power supply: External charger 220VAC 50Hz 3VA
14. Installation connector: M20X1.5 can be processed according to customer requirements
Precautions for use
1. The instrument should be placed in a dust-free and non corrosive environment. If there are special requirements, please specify the pressure calibrator in the contract.
2. When the instrument is not in use, the power should be turned off. If it is not in use for a long time, it should be charged once every three months.
3. The instrument has sufficient overload capacity, but do not overload severely, otherwise it will cause damage to the sensor and render the instrument unusable.
4. Instrument sensors belong to high-precision products, and the surface of the silicon diaphragm should not collide with solids, otherwise it will damage the sensor.
5. Without professional testing skills and equipment, do not open the hood for maintenance, and do not adjust internal components or replace materials, otherwise the reliability of the instrument cannot be guaranteed.
6. Do not let electric soldering irons or other heating elements near the display screen to prevent burning and damaging the plastic material.
7. Do not use chemical solvents such as gasoline and alcohol to clean the panel.
8. Although the instrument has seismic design, it should still be handled with great care, especially when used on site, to avoid falling or colliding.

The storage of pressure calibrators should be avoided in the following places:
1. High humidity
2. Near high-temperature heat sources
3. There is a strong vibration pressure calibrator present
4. Corrosive gas pressure calibrator