1、 Product Introduction and Application: LCZ-110A Twisted Ring Load Sensor adopts a twisted ring structure, with high accuracy, sensitive response, good vibration resistance, and easy installation. It is suitable for various electronic scales, scales, force and weighing applications

1、 Product Introduction and Usage:
The LCZ-110A torsion ring load sensor adopts a torsion ring structure, which has high accuracy, sensitive response, good vibration resistance, and is easy to install. It is suitable for various electronic scales, scales, and occasions of force measurement and weighing.
2、 Product structure and external dimensions:

| Range |
ΦA |
ΦB |
ΦC |
H |
J |
K |
| 2.2t |
Φ49 |
Φ20 |
Φ60 |
43 |
- |
7.5 |
| 4.7t |
Φ52 |
Φ20 |
Φ60 |
43 |
- |
7.5 |
| 10t |
Φ75 |
Φ30 |
Φ75 |
50 |
7 |
6.5 |
| 15t |
Φ75 |
Φ30 |
Φ75 |
50 |
7 |
6.5 |
| 22t |
Φ75 |
Φ30 |
Φ75 |
50 |
7 |
6.5 |
| 33t |
Φ95 |
Φ40 |
Φ95 |
65 |
7 |
10 |
| 47t |
Φ130 |
Φ60 |
Φ130 |
75 |
7 |
14 |
| 68t |
Φ130 |
Φ60 |
Φ130 |
85 |
7 |
14 |
| 100t |
Φ150 |
Φ70 |
Φ150 |
90 |
7 |
16 |
| 150t |
Φ150 |
Φ70 |
Φ150 |
100 |
7 |
16 |
| 220t |
Φ225 |
Φ100 |
Φ225 |
130 |
10 |
24 |
| 330t |
Φ225 |
Φ100 |
Φ225 |
145 |
10 |
24 |
Sensor wiring diagram: Sensor force diagram:


TECHNICAL INDEX
| Parameters |
Technical Parameter |
Parameters |
Technical Parameter |
| range |
2.2t~330t |
output resistance |
1.4K±5Ω |
| Output sensitivity |
2.85±0.05mV/V |
Working temperature range |
-20~+70℃ |
| Nonlinear |
±0.05~±0.1%F.S. |
Safe Overload |
150%F·S |
| hysteresis error |
±0.08%F.S. |
insulation resistance |
≥2000MΩ |
| Repeatability error |
±0.05%F.S. |
Excitation |
5V~12V |
| creep |
±0.05%F.S. |
protection grade
|
IP66
|
| zero temperature |
±0.05%F.S./10℃ |
material
|
Alloy steel, stainless steel |
| Sensitivity temperature coefficient |
±0.05%F.S./10℃ |
cable |
Φ5x3m |
| Input Resistance |
1.45K±50Ω |
|
|
Retail: Contact customer service - Inquire about product parameters - Confirm product model - Payment - Logistics delivery - Sign for receipt
Key customers: Contact customer service - Consult industry solutions - Confirm product model parameters - Sign relevant technical contracts - Payment - Logistics shipment - Sign for receipt
1. Longlv provides customers with installation and commissioning services, as well as other technical consultations. If necessary, technical personnel can provide on-site technical training. If the customer has any technical questions, the technical personnel will provide a response within 4 hours.
2. Longlv products are designed and produced strictly in accordance with the ISO9001 international quality system, with a 1-year warranty for sensor products Instrument products come with a 3-year warranty, 7-day return and exchange, and lifetime maintenance. (Human damage is not covered by the warranty, and customized products without quality problems cannot be returned or replaced.)
3. For returns and exchanges caused by quality issues, Longlv will bear the shipping costs for returns and exchanges. The cost of returns and exchanges for non quality issues will be borne by the customer.
Note: Quality issues refer to customized parameters such as functionality, size, specifications, installation methods, etc. that are not customized according to customer requirements, resulting in functional discrepancies, dimensional errors, and inaccurate accuracy (excluding within the error range).
Customized products require both parties to confirm the drawings before processing and production. If the product does not meet the customer's requirements, a written objection must be raised within two weeks. If the customer fails to raise an objection within the prescribed time limit, it will be deemed as acceptance.
If an objection is raised within the deadline and it is confirmed by both parties that it is a product quality issue or the production did not meet the requirements confirmed by both parties, it can be exchanged or refunded. If there are no quality issues and the shipping model is complete and correct compared to the contracted model, no return or exchange services will be provided.
4. Products that need to be returned to the factory for repair will receive test results within 3 working days and the repair will be completed within 7 working days.
After-sales Consulting