Ke Li SB static load weighing module, with a range of 0.3t-25t optionalFeatures:
1Three types of structures: fixed, floating, and semi floating, allowing for slight deformation of the container
2Compact structure, no need for additional accessories;
3The sensor is sealed and welded, with strong environmental adaptability;
4Supporting bolts to prevent equipment from overturning and facilitate maintenance;
5Grounding device to protect sensors from power surge impact;
6Overload protection device, protecting the sensor from impact force;
Technical Specifications:
Rated load: |
0.3tThe0.5tThe1tThe2tThe3tThe5tThe7.5tThe8tThe10tThe15tThe20tThe25t |
Rated temperature: |
-10~+40℃ |
Accuracy level: |
C3 |
Working temperature range: |
-30~+70℃ |
Sensitivity: |
2.0±0.002mV/V |
Safe load: |
150%F.S |
Creep(30Minutes): |
±0.03%F.S |
Additional excitation voltage: |
10~12V DC |
Zero point balance: |
±1%F.S |
Sealing grade: |
IP66(0.3t~0.5t) IP67(1t~25t) |
Zero temperature effect: |
±0.02%F.S/10℃ |
||
Sensitivity temperature effect: |
±0.02%F.S/10℃ |
Material: |
alloy steel stainless steel |
Input impedance: |
400±20Ω |
||
Output impedance: |
352±3Ω |
Cable: |
2.6m(0.3t~2t),3.5m(3t),5.2m(5t~8t),7m(10t),12m(15t~25t) |
Insulation resistance: |
≥5000MΩ |

Ke Li SB static load weighing module, with a range of 0.3t-25t optionalInstall
1Module classification:
Fixed, semi floating, fully floating
2Installation method:
Radial installation method, tangential installation method, rectangular installation method
The weighing system generally consists of a fixed module, a semi floating module, and several floating modules. The semi floating module must be installed diagonally on the fixed module; The installation fulcrum of the fixed module will not produce horizontal displacement, so in the system design process, the pipeline and electrical connection parts should be close to this point; The semi floating and floating modules enable the system to move around a fixed point, eliminating the impact of container deformation on weight.
3On site installation precautions:
Please check the basic condition before installation: the plane drop of each installation point should be controlled within3mmWithin, the levelness of the same foundation surface should be controlled within1mm/mWithin, the basic bearing capacity requirement is greater than the range of the sensor.
1)After module installation, please loosen the limit screw and nut;
2)Loosen the nut downwards with the nutATighten the lower bearing plate while the washer on the nut falls down, allowing the carrier to shake freely.
3)Cable color code (conventional sensor line standard, mainly based on the certificate line standard)
+motivation |
-motivation |
+feedback |
-feedback |
+signal |
-signal |
block |
red |
black |
blue |
yellow |
green |
white |
Thick black |
4Connection between containers and pipelines:
There are various ways to connect containers and pipelines, collectively referred to as soft connections. Different software connection methods can be designed based on the user's on-site usage conditions.
1)Flexible hose connection;2)UType flexible hose connection;3)Bellows connection;4)Sleeve connection;
In order to ensure the accuracy of weighing electronic containers, different soft connection methods must be selected based on the chemical characteristics of the substances transported in the pipeline.1)2)3)Used for non-volatile liquids,4)Used for volatile liquids.
To ensure the metrological performance of electronic containers, the following conditions must be met:
a.The container itself is not affected by any external force and can shake freely;b.Use soft connections for pipelines and containers
Note: During the equipment debugging process, if there is a large angle deviation, poor instrument zeroing, or a small or unchanged weight value after weight loading, please check whether the module limit part is stuck or slightly affected by friction; Check if there is any external force affecting other hardware connections of the device, such as the impact of dead connections in pipelines on weighing.