E-mail
jh@zjjh17.com
-
Phone
13957548110
-
Address
No. 735 Zhanghuang, Ziziwu Village, Yaojiang Town, Zhuji City, Zhejiang Province
Zhejiang Jiangheng Instrument Equipment Co., Ltd
jh@zjjh17.com
13957548110
No. 735 Zhanghuang, Ziziwu Village, Yaojiang Town, Zhuji City, Zhejiang Province
Kaimao Kimo transmitter CP211-BO differential pressure, high air volume, humidity, and temperature





KIMO CP218/CP219 multifunctional differential pressure wind speed, air volume, and temperature transmitter
Product Features
Suitable for measuring wind speed and volume inside HVAC ducts
CP218 range: 0~30 m/s, 0~1000 Pa, 0~99999 m3/h
CP219 range: 0~100 m/s, 0~10000 Pa, 0~99999 m3/h
Can be connected with an external component platinum resistance PT100 temperature probe for temperature measurement
• Temperature range for transmitter access: -100~+400 ° C (can be set to other smaller ranges)
Online automatic calibration (CP218) without the need for power outage or hose removal
Output signal: Two channel 4-wire 0~5/10 V, 0/4~20 mA (choose one)
Two sets of relay outputs
• Power supply 24 Vac/VDC or 230 Vac
• Display measurement trend arrow indicators
Industrial plastic casing, IP65 protection level
• Can choose with or without a digital display screen
• Comes with a back fixed backplate, and the transmitter rotates to fix it
Transmitter function
Measurement unit: m/s , fpm , m3/h , m3/s , l/s , cfmPa , mmH2O , mbar , inWG , mmHGaPa , KPa , hPa , °C , °F
Accuracy: ± 2% measurement value (wind speed>3 m/s, air volume)
± 0.5% measurement value (differential pressure)
± 0.2 ° C (temperature)
Response time: 1/e (63%) 0.3 s
分辨率: 0.01 m/s , 0.1 fpm,1 m3/h , 0.1 m3/s , 0.1 l/s , 1 cfm1 Pa , 0.1 mmH2O , 0.01 mbar , 0.01 inWG ,0.01 mmHG , 0.1 daPa , 0.001 kPa , 0.01 hPa,0.1 °C , 0.1 °F
Repeatability/linearity/hysteresis: ± 2 Pa (CP218), ± 10 Pa (CP219)
Allowable overpressure: 21000 Pa (CP218), 69000 Pa (CP219)
Technical Specifications
Power Supply:
24 Vac/Vdc ± 10%
230 Vac ± 10% , 50 ~ 60 Hz
Output signal:
Current: 2-channel 4~20 mA or 0~20 mA (4-wire type)
Voltage: 2-channel 0~5 V or 0~10 V (4-wire type)
Maximum load: 500 Ω (0/4~20 mA)
Minimum load: 1000 Ω (0~5/10 V)
power waste:
6 VA ( CP210-B ) / 8 VA ( CP210-H )
Relay output:
2 sets of relays 3A/230 V
meet the standard
2014/30/EU EMC ; 2014/35/EU Low Voltage
2011/65/EU RoHS II ; 2012/19/EU WEEE
Wiring port:
Screw wiring groove suitable for cable Ø 2.5 mm2
Usage environment:
Air and neutral gases
Automatic calibration:
CP218- Automatically calibrate zero point through built-in components to ensure measurement of micro differential pressure
Zero hour error free (preset to automatically calibrate every 10 minutes)
Manual calibration:
Manual zero calibration through buttons
Measurement medium:
Air and neutral gases
Usage conditions:
-10~+50 ° C, non condensing, 0~2000 m
Storage temperature:
-10 ~ +70 °C
Shell material: industrial plastic, flame retardant grade UL94-V0
Protection level: IP65
Display screen: LCD display, size: 75 x 40 mm
Digital height: measured value: 10 mm; Unit: 5 mm
Pressure interface: metal barbed interface, Ø 6.2 mm
Cable joint: maximum diameter of cable Ø 8 mm
Weight: 320 g
Kaimao Kimo transmitter CP211-BO differential pressure, high air volume, humidity, and temperature