KEW2413FA leakage current clamp meter | KEW2413FA leakage current clamp meter

NegotiableUpdate on 03/25
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
1. Pointer leakage current clamp meter.
Product Details

KEW2413FA leakage current clamp meter | Product introduction of KEW2413FA leakage current clamp meter:KEW 2413FAIt is a pointer type leakage current clamp meter with a large aperture design, suitable for three-phase wire testing, with a high sensitivity range of 10mA maximum scale value.

KEW2413FA leakage current clamp meter | Detailed features of KEW2413FA leakage current clamp meter:

1. Pointer leakage current clamp meter.

2. Adopting a large-diameter design, suitable for testing three-phase wires.

3. The frequency filter switch can eliminate harmonic effects.

4. The range with a maximum scale value of 10mA for high sensitivity.

5. A pointer shutdown device that can fix the test value.

6. Analog output terminal.

7. The minimum resolution is 0.2mA.

KEW2413FA leakage current clamp meter | Technical parameters of KEW2413FA leakage current clamp meter:

This parameter table is provided byKyoritsuFlukeTESTODeltaTRAKDistrict General AgentShenzhen Haixu Instrument and Meter Co., Ltd. provides original and authentic products

Measurement range

accuracy
aca
(50/60Hz)
10/50/250mA/1/5/100/500A maximum scale value±4%
± 7% of the maximum scale value between 501A and 1000A
aca
(WIDE)

10/50/250mA/1/5/100/500A
The maximum scale value±3%(50/60Hz)
± 6% of the maximum scale value(40Hz~400Hz)
± 20% of the maximum scale value (400Hz~1kHz)501A~100A
± 6% of the maximum scale value (50/60Hz)
± 30% of the maximum scale value (40Hz~1kHz)

Diameter of the tested conductor

Maximum diameter of 68mm
Frequency range
40Hz~1kHz
Analog Output
AC/DC 100mV relative to the maximum value of each range
withstanding voltage
AC3000V/1 minute
Using batteries
006P(9V)×1. The possible duration of continuous use is about 500 hours
External dimensions
272(L)×129(W)×48.5(D)mm
weight
About 630g (including battery)
attachment
9087 (portable leather case) battery 006PX1 User Manual
option
7073 (2WAY analog output line)

Instrument recommendation: 11050 thermometer, 15000 thermometer