KEW2413F leakage current clamp meter | KEW 2413F leakage current clamp meter with extra wide clamp, suitable for testing leakage current of three or four wire (three-phase) wires. Equipped with a frequency filtering switch, it can eliminate harmonic effects.
KEW2413F leakage current clamp meter | Detailed features of KEW 2413F leakage current clamp meter:
1. Extra wide clamp, suitable for testing leakage current of three or four wire (three-phase) wires.
2. Frequency filtering switch can eliminate harmonic effects.
3. Peak holding function.
4. Analog output port
Technical parameters of KEW2413F leakage current clamp meter | KEW 2413F leakage current clamp meter:
This parameter table is provided byKyoritsu、Fluke、TESTO、DeltaTRAKDistrict General Agent—Shenzhen Haixu Instrument and Meter Co., Ltd. provides original and authentic products
|
Measurement range
・ accuracy |
AC current (50/60Hz)
|
200mA/2/20/200A/1000A |
|
Alternating Current (WIDE)
|
200mA/2/20/200A/1000A
±1%rdg±2dgt(200mA/2A/20A)(50/60Hz) ±2%rdg±2dgt(200A 0~500A) ±5.5%rdg(501~1000A) |
|
|
Conductor diameter
|
maximumØ68mm
|
|
|
Frequency range
|
40Hz~1kHz
|
|
|
Analog Output
|
AC/DC200mV relative to the maximum value of each range (100mV for 1000A range)
|
|
|
Safety specifications
|
IEC61010-1 CAT. III 300V IEC61010-2-032
|
|
|
withstanding voltage
|
3000V AC/min
|
|
|
power supply
|
006P(9V)×1
|
|
|
External dimensions
|
250(L)×1 30(W)×50(D)mm
|
|
|
weight
|
About 570g
|
|
|
attachment
|
9064 (Carrying Case) 6F22 × 1 User Manual
|
|
|
option
|
7073 (output line)
|
|
Instrument Introduction: AT-9950DIS/9950T/950A/950B Multimeter DT-178A/178B Vibration Recorder