KEW2056R digital clamp ammeter | KEW2056R clamp ammeter

NegotiableUpdate on 03/25
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Product features of KEW 2056R digital clamp meter | clamp ammeter KEW2056R | KEW 2056R current tester:
Product Details

KEW2056R digital clamp ammeter | Product introduction of KEW2056R clamp ammeter:

The KEW 2056R digital AC/DC clamp meter can test the voltage and current in extremely high/low electrical circuits, suitable for distribution stations, electrical energy use, and maintenance fields.

Product features of KEW 2056R digital clamp meter | clamp ammeter KEW2056R | KEW 2056R current tester:

1. The CAT.IV clamp meter can test the voltage and current in extremely high/low electrical circuits.

2. Suitable for distribution stations, electricity usage and maintenance fields.

3. Accurate testing of true effective value.

4. The red LED indicates the "non-contact voltage" function, warning users of the presence of AC voltage in the electrical circuit.

5. The dual injection molding design of the shell provides a more comfortable grip.

6. A bar chart displaying 6039 digits.

7. The MAX/MIN function simply retains the maximum and minimum values during testing.

8. The design of the KEW 2056R digital clamp meter complies with the international safety specification IEC61010-1 CAT.IV 600V

Technical specifications of KEW2056R digital clamp ammeter:

This parameter table is provided byKyoritsuFlukeTESTODeltaTRAKDistrict General AgentShenzhen Haixu Instrument and Meter Co., Ltd. provides original and authentic products

aca

0~600.0/1000A
±2.0%rdg±5dgt (50/60Hz)
±3.5%rdg±5dgt (40Hz~400Hz )

dc current

0~600.0/1000A
±1.5%rdg±5dgt
AC voltage
6/60/600V (automatic range)
±1.5%rdg±4dgt (50/60Hz)
±3.5%rdg±5dgt(40Hz~400Hz )
DC voltage
600m/6/60/600V (automatic range)
±1.0%rdg±3dgt
resistance
600/6k/60k/600k/6M/60M Ώ (automatic range)
±1%rdg±5dgt(600~6MΏ) ±5%rdg±8dgt(60MΏ)
Conducting buzzing sound
Beep below 100 Ώ
Frequency/DUTY
10/100/1kHz/10kHz (automatic range)/0.1~99.9%

capacitance

400n/4µ/40µF (Automatic Range)

temperature

-50 ℃~+300 ℃ (when using temperature probe 8216)
Conductor diameter
maximumØ40mm
Safety specifications
IEC61010-1 CAT IV 600V Pollution Level 2 IEC61010-031 IEC61010-2-032 IEC61326
withstanding voltage
6880V AC/5 seconds
battery
R03(1.5V)(AAA)×2
External dimensions
254(L)×82(W)×36(D)mm
weight
About 310g (including battery)
attachment
7066 (test line) 9094 (carrying leather case)
R03 × 2 User Manual

option

8216 (temperature probe)

Instrument recommendation: DG7 insulation resistance tester DG8 insulation resistance tester