KEW 2431 leakage current clamp meter | Function description of KEW 2431 leakage current clamp meter:
1. Equipped with a frequency selector to eliminate harmonic effects.
2. Three AC current ranges are 20mA/200mA/200A.
3. No operation within 10 minutes, the power can be automatically turned off, which has the advantage of energy saving and power-saving.
KEW 2431 leakage current clamp meter | Detailed features of KEW 2431 leakage current clamp meter:
1. The frequency selector eliminates harmonic effects.
2. Three AC current ranges: 20mA/200mA/200A.
3. The resolution can reach 0.01mA at a range of 20mA.
4. Automatic shutdown function (can automatically shut down after 10 minutes).
5. Rotary switch for easy startup and range selection.
KEW 2431 leakage current clamp meter | Measurement range and technical indicators of KEW 2431 leakage current clamp meter:
This parameter table is provided byKyoritsu、Fluke、TESTO、DeltaTRAKDistrict General Agent—Shenzhen Haixu Instrument and Meter Co., Ltd. provides original and authentic products
|
Measurement range
・ accuracy |
aca
(50/60Hz) |
20/200mA/200A
± 3% ± 5 digits of reading (20/200mA/100A) ± 5% ± 5 digits of the reading (200A) |
|
aca
(WIDE) |
20/200mA/200A
± 2% ± 4 digits of reading (20/200mA/100A) (50/60Hz) ± 5% ± 6 digits of reading (20/200mA/100A) (40-400Hz) ± 5% ± 4 digits of reading (200A) (50/60Hz) |
|
|
Diameter of the tested conductor
|
Maximum Φ 24mm
|
|
|
Response time
|
About 2 seconds
|
|
|
withstanding voltage
|
AC3700V/1 minute
|
|
|
Safety specifications
|
IEC61010-1 CAT. III 300V lEC61010-2-032
|
|
|
Using batteries
|
LR-44(1.5V)×2
|
|
|
External dimensions
|
149(L)×60(W)×26(D)mm
|
|
|
weight
|
About 120 grams
|
|
|
attachment
|
9090 (packaging box) LR-44 × 2 instruction manual
|
|
|
option
|
8004/8008 (Converter) 8021 (Booster)
|
|
Instrument recommendation: AT-9965 multimeter AT-9906DIS multimeter