- Phone
-
Address
Pukou District, Nanjing City
Nanjing Lianjun Fluid Technology Co., Ltd
Pukou District, Nanjing City
NameJierui pressure reducing valve
Job nature: Air(40 micron filter screen)
Action mode: internally guided
Output pressure:0.03-5.5Mpa
Operating Temperature-10+60℃
Maximum pressure resistance:3000psi
Valve body thread:1/2NPT
Instructions for Use:
1. Install the product on a gas cylinder and perform leak detection using soap water or testing solution.
2. 2. Please confirm that the pointer of the pressure gauge is pointing to '0' without pressurization. If it is not pointing to '0', please stop using the pressure gauge as the product needs to be inspected and repaired.
3. Before using the product, please check if there are any impurities or grease dust residue at the interface of the gas pressure reducer. If there are any impurities or grease residue, please blow and remove them.
4. Before inserting gas, please confirm whether the pressure regulating handle of the gas pressure reducer is in a relaxed state. If the pressure handle of the gas pressure reducer is in a tightened state, please adjust the handle to a relaxed state (turn left).
5. When installing a pressure regulator onto a gas cylinder and adding gas, please do not stand directly in front of the gas regulator. Instead, slowly open the valve of the gas cylinder.
NameJierui pressure reducing valve
Job nature: Air (40 micron filter)
Action mode: internally guided
Output pressure: 0.03-5.5Mpa
Working temperature: -10+60 ℃
Maximum pressure resistance: 3000psi
Valve body thread: 1/2NPT
Instructions for Use:
1. Install the product on a gas cylinder and perform leak detection using soap water or testing solution.
2. 2. Please confirm that the pointer of the pressure gauge is pointing to '0' without pressurization. If it is not pointing to '0', please stop using the pressure gauge as the product needs to be inspected and repaired.
3. Before using the product, please check if there are any impurities or grease dust residue at the interface of the gas pressure reducer. If there are any impurities or grease residue, please blow and remove them.
4. Before inserting gas, please confirm whether the pressure regulating handle of the gas pressure reducer is in a relaxed state. If the pressure handle of the gas pressure reducer is in a tightened state, please adjust the handle to a relaxed state (turn left).
5. When installing a pressure regulator onto a gas cylinder and adding gas, please do not stand directly in front of the gas regulator. Instead, slowly open the valve of the gas cylinder.