Phone
1390965212918655266579
-
Address
Longzihu District, Bengbu City
Bengbu Longzihu District Jinli Sensor Factory
1390965212918655266579
Longzihu District, Bengbu City
JL corrugated tube sensors are mainly used in electronic ground scales, silo scales, track scales and other places.
The JHBU series of wheel amplitude sensors adopts foil strain gauges attached to alloy steel elastic bodies, which have the characteristics of high accuracy, strong resistance to lateral forces and eccentric loads, and good sealing performance. They can be used in electronic ground scales, silo scales, track scales and other places.
Technical parameters:
|
range
|
0.2, 0.5, 1.5, 10, 20, 30, 50 tons
|
|
sensitivity
|
2 mv±0.1 mv /V
|
|
Nonlinear
|
±0.03%F·S
|
|
hysteresis error
|
±0.03%F·S
|
|
Repeatability error
|
±0.02%F·S
|
|
Temperature Effect On Zero
|
±0.02%F·S/10℃
|
|
Temperature Effect On Output
|
0.05%F·S/10℃
|
|
creep
|
0.05%F·S/30min
|
|
Input impedance
|
385±10Ω
|
|
Output Impedance
|
350±5Ω
|
|
insulation resistance
|
≥5000 MΩ
|
|
Supply bridge voltage
|
9-15 VDC, recommended 10V
|
|
Working temperature range
|
-20 -- +70℃
|
|
Allow overload
|
150%F·S
|
|
material
|
alloy steel
|
|
Sealing grade
|
IP67
|