JG8001-NOXNitrogen oxide analyzer
handmentionAnalysis of nitrogen oxides in formulaceremonyUsed for mobile devices that require detection and analysis of nitrogen oxide gas concentrationOccasions for temperature and humidity measurement,Gas analyzeradoptReal time display of concentration on 3.5-inch clear color screen,We use the best products in the current industryelectrochemistryOr infrared, catalytic combustion, thermal conductivityPID photoionizationPrinciple of gas sensor、Swiss precision capacitive digital temperature and humidity sensor.It can detect and analyze gas concentrations in pipelines, confined spaces, and atmospheric environments, as well as detect gas leaks, detecting gas types exceeding500 types, and can also detect and analyze various background gases such as nitrogen or oxygenconcentrationSingle gasPurity.
Portable nitrogen oxidesanalyzeInstrument features:
● Waterproofsplash、DustproofExplosion proof and shock resistantIntrinsic safety circuitdesign, anti-static, anti electromagnetic interference
●Don't protect yourselfIP66, Built in water vapor and dust filters to prevent sensor and instrument damage caused by water vapor and dust
●Built in pump suction measurement,responsiveThe sampling distance is greater than10 meters,
Positive or negative pressure-0.3~2 kilograms of gas●The 3.5-inch clear color screen displays real-time concentration, alarm, time, temperature, humidity, storage, communication, and printing
●large capacityData storage function, with a standard storage capacity of 100000 pieces of data, and larger capacities can be customized.
●Automatic recognition of infrared communication interface, USB interface, RS232 interface, optional built-in or external wireless infrared printer
●USB charging interface, can be charged with a computer or power bank, compatible with mobile phone chargers, overcharge, overdischarge, overvoltage, short circuit, overheating protection
● Adopting10000mALarge capacity rechargeablemoleculepolymerBattery, capable of long-term continuous operation
● Sound and lightAlarm, visual alarm, undervoltage alarm, fault alarm, and multi-directional stereoscopic display of alarm status during alarm.
The alarm value can be set,The alarm mode can be selected as low alarmAlarm, interval alarm, weighted average alarm
● AccuracyTemperature and humidity measurement (optional), along with temperature compensation for the sensor, within the temperature range of the instrument-40~70 degrees
●Low can be detected0.001PPM,candetection99.999%Vol,Support low range automatic switching (to be specified when ordering).
●It can be detected in real-time or timed (for situations where the amount of gas being measured is relatively small), and the pump can be turned off to extend the start-up time when not detected.
●Optional simultaneous detection of 1~6 typesGas, unit free switching,Conventional gases do not require input of molecular weight, while special gases do,
Automatically calculate and switch based on the required molecular weight input, with units available for selection:PPM、mg/m3、Vol%、LEL%、PPHM、ppb、mg/L
●threeThe display modes can be switched: simultaneously displaying the concentrations of four gases, cyclically displaying the concentration of a single channel gas, real-time curves for each channel
●The Chinese and English interfaces are selectable, with the default Chinese interface,Concise Chinese or English operation tips, easy for users of all ages to operate
● Data recovery function,It can be restored or fully restored, and concentration calibration errors are automatically identified and prevented to avoid adverse effects caused by human factors
●Zero point automatic tracking, multi calibration of target points, ensuring measurement linearity and accuracy, and meeting both standards and local metrology bureau standards.
●Capable of recording calibration logs, maintenance logs, troubleshooting strategies, sensor lifespan expiration reminder, and next concentration calibration time reminder function
Portable nitrogen oxidesanalyzeTechnical parameters of the instrument:
Gas detection:nitrogen oxidesNOXOptional: Simultaneous detection1~6 types, depending on the sensor and on-site environment
Detection range:0~10ppm、100, 1000, 20005000ppm optional, other ranges can be customized
Resolution:0.01ppmor0.001ppm(0~10ppm);0.01ppm(0~100ppm),0.1ppm(0~1000ppm),
1ppm(0~1000ppmabove),0.1%LEL(0~LEL)、0.01%Vol or 0.001% Vol (0~99.999%Vol)
Detection principle:ElectrochemistryInfrared, thermal conductivity, PID photoionization, catalytic combustion, depending on gas type, range, and on-site environment
sensor
Detection method:built-inpump-suction type, traffic800 milliliters per minute
Display mode:3.5-inch 320X240 resolution large screen clear color screendisplay
Detection accuracy:≤±2%(F.S)More precise and customizable
line sex Degree:≤±2%
heavy again Sex:≤±2%
Uncertainty:≤±2%
Alarm method:audible and visual alarmVisual alarm, sound and light+Visual alarm, turn off alarm
Response time:T90≤20second
Recovery time:≤30second
Working power supply:DC3.6V
Usage environment:Temperature-40℃~+70℃; Relative humidity ≤0-99%RH
Sample gas temperature:-40℃~+70℃Optional temperature sampling and cooling filter handle or temperature and humidity pretreatment system can detect 1300℃The concentration of flue gas
Temperature display:-40℃~+120℃Accuracy 0.5℃
Humidity display:0~100%RHAccuracy 3% RH
Battery capacity:3.6VDC,10000mARechargeable molecular polymer battery, withOvercharge, overdischarge, overvoltage, short circuitProtection function
Data storage:Standard capacity100000 pieces of data, USB storage, unlimited capacity, supports local viewing, deletion, or data export,
Communication interface:Infrared, USB, RS232 automatic recognition
Explosion proof type:intrinsically safe
Explosion proof mark:Exia II CT4
Protection, etc.:IP66. Rain and water splashes, dust prevention
Application scenarios:All occasions requiring gas concentration detection and analysis, including petroleum, chemical, pharmaceutical, environmental protection, gas distribution, flue gas analysis, air treatment, etc
|
The measurement range of the tested gas can be selected with range resolution and response time |
||||
|
Flammable gas (EX) |
0-100%LEL |
0-100%VOL |
0.1%LEL/0.1%VOL |
≤10S |
|
Oxygen (O2) |
0-30%VOL |
0-25%VOL |
0.01%VOL |
≤10S |
|
Carbon monoxide (CO) |
0-1000ppm |
0-2000ppm |
0.1ppm/1ppm |
≤10S |
|
Hydrogen sulfide (H2S) |
0-100ppm |
0-1000ppm |
0.01ppm/0.1ppm |
≤10S |
|
Ammonia (NH3) |
0-100ppm |
0-200ppm |
0.01ppm/0.1ppm |
≤10S |
|
Chlorine gas (CL2) |
0-10ppm |
0-100ppm |
0.01ppm/0.1ppm |
≤10S |
|
Hydrogen chloride (HCL) |
0-20ppm |
0-100ppm |
0.01ppm/0.1ppm |
≤10S |
|
Nitric oxide (NO) |
0-100ppm |
0-250ppm |
0.01ppm/0.1ppm |
≤10S |
|
Nitrogen dioxide (NO2) |
0-20ppm |
0-100ppm |
0.01ppm/0.1ppm |
≤10S |
|
Formaldehyde (CH2O) |
0-10ppm |
0-50ppm |
0.01ppm/0.1ppm |
≤10S |
|
Ozone (O3) |
0-10ppm |
0-100ppm |
0.01ppm/0.1ppm |
≤10S |
|
Carbon dioxide (CO2) |
0-2000ppm |
0-100%VOL |
1ppm/0.01%VOL |
≤10S |
|
JG3000 series gas selection table |
|
|
Gas type and molecular formula |
Optional range (range not listed can be customized by phone); The letter 'Chang' indicates the standard range |
|
CO Carbon Monoxide |
0-50, 100, 200, 500, 1000 (normal), 2000, 5000ppm |
|
H2S hydrogen sulfide |
0-10, 20, 50, 100, (normal), 200, 0-500, 1000, 2000ppm |
|
O2 oxygen |
0-5%, 25%, 30% (Regular), 50% VOL |
|
EX may have natural gas |
0-100% LEL (normal) |
|
N2 nitrogen gas |
0-100%. Vol (often) |
|
NH3 ammonia gas |
0-50、100ppm(常)、200、500、1000、2000、5000ppm |
|
CL2 chlorine gas |
0-10 (normal), 20, 50, 100, 200, 500 ppm |
|
VOC Total Volatile Organic Gas Detector |
0-2、10、50、100、200、1000、2000、6000、10000PPM |
|
H2 hydrogen gas |
0-500, 1000 (normal), 2000, 5000, 10000, 20000, 40000 ppm |
|
CH2O formaldehyde |
0-10 (normal), 20, 50, 100, 500, 1000ppm |
|
O3 ozone |
0-1, 5, 10, 20, 50 (normal), 100, 200, 500, 1000ppm |
|
CO2 carbon dioxide (infrared) |
0-1000, 2000 (normal), 5000, 10000, 50000ppm |
|
CO2 carbon dioxide (infrared) |
0-10%、20%、50%、100%Vol |
|
NO nitric oxide |
0-100, 0-250 (normal), 500, 1000, 2000, 4000ppm |
|
NO2 Nitrogen dioxide |
0-20 (normal), 50, 100, 500, 1000, 2000, 4000ppm |
|
NOX nitrogen oxides |
0-20 (normal), 50, 100, 500, 1000, 2000, 4000ppm |
|
SO2, sulfur dioxide |
0-10、20、100(常)、150ppm、200、1000、2000 ppm |
|
ETO epoxyethane |
0-10 (normal), 20, 50, 100ppm |
|
Ethylene oxide ETO |
0-500、1000ppm |
|
PH3 phosphine |
0-10 (normal), 20, 50, 100, 1000, 2000, 3000, 5000ppm |
|
HCL hydrogen chloride |
0-10 (normal), 20, 50, 100ppm |
|
HCN hydrogen cyanide |
0-10 (normal), 20, 50, 100ppm |
|
COCL2 phosgene |
0-1ppm (normal) |
|
CLO2 chlorine dioxide |
0-1, 10 (normal), 20, 50ppm |
|
SiH4 silane |
0-10, 50ppm (normal) |
|
F2 fluorine gas |
0-1 (normal), 10ppm |
|
HF hydrogen fluoride |
0-10 (normal), 50ppm |
|
HBr hydrogen bromide |
0-10, 50 (normal), 100ppm |
|
B2H6 diborane |
0-5, 10, 50ppm (normal) |
|
AsH3 arsine |
0-1, 10 (normal), 50ppm |
|
GeH4 Germanane |
0-1ppm (normal) |
|
N2H4 hydrazine, hydrazine |
0-1ppm (normal) |
|
THT tetrahydrothiophene |
0-100ppm、0-50mg/m3(常)、0-100mg/m3 |
|
Br2 bromine gas |
0-5, 10 (normal), 50ppm |
|
C2H2 acetylene |
0-100ppm (normal) |
|
CS2 carbon disulfide |
0-100% LEL, 50ppm (normal) |
|
C3H3N 丙烯腈 |
0-10, 20 (normal), 50, 100ppm |
|
CH3COOH ethyl acetate |
0-10、20p、 50, 100 (normal), 500, 1000ppm |
|
C2H4 ethylene |
0-10 (normal), 20, 50, 100, 500, 1000ppm |
|
CH3OH methanol |
0-50, 100 (normal), 500, 1000ppm |
|
C2H5OH 乙醇 |
0-10, 50, 100 (normal), 500, 1000ppm |
|
CH4S Methyl Thiol |
0-20 (normal), 50ppm |
|
C2H3Cl vinyl chloride |
0-50, 100ppm (usual) |
|
Chloromethane (monochloromethane, dichloromethane, etc.) |
0-50、100ppm |
|
C8H8 styrene (electrochemical) |
0-50、200、1000、10000ppm |
|
Styrene (PID) |
0-100 (normal), 200, 1000, 6000ppm |
|
Total volatile organic compounds (TVOC) PID |
0-1,10,50PPM, (High precision, high resolution 0.001PPM) |
|
Total volatile organic compounds (TVOC) PID |
0-100 (normal), 2001000, 6000, 10000ppm |
|
Bromomethane (CH3Br) (PID photoionization) |
0-100 (normal), 2001000, 10000PPM |
|
Bromomethane (CH3Br) (electrochemical) |
0-50100 (normal), 2001000ppm |
|
C6H6 benzene (PID photoionization) |
0-1, 10, 50PPM (high precision, high resolution 0.001PPM) |
|
C6H6 benzene (PID photoionization) |
0-100 (normal), 2001000, 600010000ppm |
|
Toluene (PID photoionization) |
0-1, 10, 50PPM (high precision, high resolution 0.001PPM) |
|
Toluene (PID photoionization) |
0-100 (normal), 200,1000, 6000, 10000ppm |
|
Xylene (PID photoionization) |
0-1, 10, 50PPM (high precision, high resolution 0.001PPM) |
|
Xylene (PID photoionization principle) |
0-100 (normal), 2001000, 600010000ppm |
|
Total volatile organic compounds (TVOC) electrochemistry |
0-10,50,100PPM |
|
C6H6 benzene (electrochemical) |
0-10,50,100PPM |
|
Toluene (electrochemical) |
0-10,50,100PPM |
|
Xylene (electrochemical) |
0-10,50,100PPM |
|
The ranges listed in the above table are conventional ranges and are not included in the list. If you need to test, please consult our sales personnel Jinggong Instrument provides you with comprehensive technical support and after-sales service! Details consultation: WeChat Same Account
|
|