E-mail
0595188@163.com
- Phone
-
Address
No. 5, Lianhu Industrial Zone, Tangxia Town, Dongguan City
Dongguan Tangxia Precision Instrument Factory
0595188@163.com
No. 5, Lianhu Industrial Zone, Tangxia Town, Dongguan City
JG8000-N2 Nitrogen Analyzer
JG8000-N2Nitrogen analysisinstrumentUsed for mobile devices that require detection and analysis of nitrogen concentrationOccasions for temperature and humidity measurement,Liuhe gas analyzeruseReal time display of concentration on 3.5-inch clear color screen,We use the best products in the current industryelectrochemistryOr infrared, catalytic combustion, thermal conductivityPID photoionizationPrinciple of gas sensor、Swiss precision capacitive digital temperature and humidity sensor.It can detect and analyze gas concentrations in pipelines, confined spaces, and atmospheric environments, as well as detect gas leaks, detecting gas types exceeding500 types, and can also detect and analyze various background gases such as nitrogen or oxygenconcentrationSingle gasPurity.
JG8000-N2 NitrogenanalysisInstrument features:
● Waterproofsplash、DustproofExplosion proof and shock resistantIntrinsic safety circuitdesignAnti static, anti electromagnetic interference,
Certified through standard testing and CMC measuring instrument production license
●Don't protect yourselfIP66, Built in water vapor and dust filters to prevent sensor and instrument damage caused by water vapor and dust
●Built in pump suction measurement,Quick responseThe sampling distance is greater than10 meters,Special gas path design for direct detection
Positive or negative pressure-0.3~2 kilograms of gas has no effect on the measurement results
●The 3.5-inch clear color screen displays real-time concentration, alarm, time, temperature, humidity, storage, communication, printing, etc
The battery level, charging status, and other information are displayed on the menu interface using clear simulation icons to show the function names of each menu
●high-capacityData storage function, with a standard storage capacity of 100000 pieces of data, and larger capacities can be customized. Optional
USB or SD card storage function, supporting real-time storage, scheduled storage, or only storing alarm concentration data and
Time, support for viewing and deleting data locally, and can also be accessed through USB, infrared communication, RS232 interface
Upload the data to the computer, use the upper computer software to analyze the data, store and print it.
●Automatic recognition of infrared communication interface, USB interface, RS232 interface, optional built-in or external wireless infrared printer,
Print content: company name, gas name, date and time, environmental temperature and humidity, concentration data, test results (whether qualified)
●USB charging interface, can be charged with a computer or power bank, compatible with mobile phone chargers, overcharge, overdischarge, overvoltage, short circuit, overheating protection,
5 precise battery level display, supports USB hot plugging, and the detector can work normally during charging
● Adopting10000mALarge capacity rechargeablenumeratorpolymerBattery, capable of long-term continuous operation
● Sound and lightAlarm, visual alarm, undervoltage alarm, fault alarm, and multi-directional stereoscopic display of alarm status during alarm.
The alarm value can be set,The alarm mode can be selected as low alarmAlarm, interval alarm, weighted average alarm
● AccuracyTemperature and humidity measurement, along with temperature compensation for sensors, within the temperature range of the instrument-40~70 degrees,Capable of detecting gases at 1300 degrees Celsius
●Low can be detected0.001PPM,approvedetection99.999%Vol,Support low range automatic switching (to be specified when ordering).
●It can be detected in real-time or timed (for situations where the amount of gas being measured is relatively small), and the pump can be turned off to extend the start-up time when not detected.
●Optional simultaneous detection of 1~6 typesGas, expanded to 18 types, units can be freely switched,Conventional gases do not require input of molecular weight, while special gases do
Automatically calculate and switch based on the required molecular weight input, with units available for selection:PPM、mg/m3、Vol%、LEL%、PPHM、ppb、mg/L
●threeMultiple display modes can be switched: simultaneously displaying four gas concentrations, large font circulating display of single channel gas concentration, real-time curve, and each channel
The automatic or manual cycle can be switched between,Can be set whether or notDisplay high, low, and gas names, and view historical curve graphs.
●The Chinese and English interfaces are selectable, with the default Chinese interface,Concise Chinese or English operation tips, easy for users of all ages to operate
● Data recovery function,Selective or full recovery is possible, and concentration calibration errors are automatically identified and prevented to avoid adverse effects caused by human factors
●Zero point automatic tracking, multi calibration of target points, ensuring measurement linearity and accuracy, and meeting both standards and local metrology bureau standards.
JG8000-N2 NitrogenanalysisTechnical parameters of the instrument:
Gas detection:nitrogenN2 Optional: Simultaneous detection1~6 types, up to 18 types of gas and temperature and humidity measurements, depending on the sensor and on-site environment
Detection range:0~Vol,0~1000, 5000, 1000050000ppm optional, other ranges can be customized
Resolution:0.01%Vol or 0.001% Vol (0~99.999% Vol, 1ppm optional
Sensor lifespan:2 years
Detection method:built-inPump suction, traffic800 milliliters per minute
Display mode:3.5-inch 320X240 resolution large screen clear color screendisplay
Detection accuracy:≤±1%(F.S)More precise and customizable
line sexually Degree:≤±1%
weight repeated Sex:≤±1%
Uncertainty:≤±1%
Alarm method:audible and visual alarmVisual alarm, sound and light+Visual alarm, turn off alarm
Response time:T90≤10second
Recovery time:≤10second
Working power supply:DC3.6V
Usage environment:Temperature-40℃~+70℃; Relative humidity ≤0-99%RH
Sample gas temperature:-40℃~+70℃Optional temperature sampling and cooling filter handle or temperature and humidity pretreatment system can detect 1300℃The concentration of flue gas
Temperature display:-40℃~+120℃Accuracy 0.5℃
Humidity display:0~100%RHAccuracy 3% RH
Battery capacity:3.6VDC,10000mARechargeable molecular polymer battery, withOvercharge, overdischarge, overvoltage, short circuitProtection function
Data storage:Standard capacity100000 pieces of data, with optional SD card and USB storage, unlimited capacity, supporting local viewing, deletion, or data exportset up
Communication interface:Infrared, USB, RS232 automatic recognition
Printer:Optional, built-in micro printer or external micro wireless infrared printer
Explosion proof type:Intrinsically Safe
Explosion proof mark:Exia II CT4
Protection, etc.:IP66. Rain and water splashes, dust prevention
External dimensions:230×210×120mm(L×H×W)
Standard attachments:InstructionsCertificate of conformity, warranty cardUSBcharger、Instrument box、、 40cm stainless steel sampling handle (1-meter hose)
Optionalenclosure:Built in micro printer, external micro wireless infrared printer, temperature and humidity measurement functionUSB storage, wireless data communication function
Temperature sampling and cooling filter handle, temperature and humidity pretreatment system, external remote sampling pump, multiple humidity and dust filters
1.2 mScalableSampling handle(1-meter hose)
Application scenarios:All occasions requiring gas concentration detection and analysis, including petroleum, chemical, pharmaceutical, environmental protection, gas distribution, flue gas analysis, air treatment, etc
|
The measurement range of the tested gas can be selected with range resolution and response time |
||||
|
Flammable gas (EX) |
0-100%LEL |
0-100%VOL |
0.1%LEL/0.1%VOL |
≤10S |
|
Oxygen (O2) |
0-30%VOL |
0-25%VOL |
0.01%VOL |
≤10S |
|
Carbon monoxide (CO) |
0-1000ppm |
0-2000ppm |
0.1ppm/1ppm |
≤10S |
|
Hydrogen sulfide (H2S) |
0-100ppm |
0-1000ppm |
0.01ppm/0.1ppm |
≤10S |
|
Ammonia (NH3) |
0-100ppm |
0-200ppm |
0.01ppm/0.1ppm |
≤10S |
|
Chlorine gas (CL2) |
0-10ppm |
0-100ppm |
0.01ppm/0.1ppm |
≤10S |
|
Hydrogen chloride (HCL) |
0-20ppm |
0-100ppm |
0.01ppm/0.1ppm |
≤10S |
|
Nitric oxide (NO) |
0-100ppm |
0-250ppm |
0.01ppm/0.1ppm |
≤10S |
|
Nitrogen dioxide (NO2) |
0-20ppm |
0-100ppm |
0.01ppm/0.1ppm |
≤10S |
|
Formaldehyde (CH2O) |
0-10ppm |
0-50ppm |
0.01ppm/0.1ppm |
≤10S |
|
Ozone (O3) |
0-10ppm |
0-100ppm |
0.01ppm/0.1ppm |
≤10S |
|
Carbon dioxide (CO2) |
0-2000ppm |
0-100%VOL |
1ppm/0.01%VOL |
≤10S |
|
JG3000 series gas selection table |
|
|
Gas type and molecular formula |
Optional range (range not listed can be customized by phone); The letter 'Chang' indicates the standard range |
|
CO Carbon Monoxide |
0-50, 100, 200, 500, 1000 (normal), 2000, 5000ppm |
|
H2S hydrogen sulfide |
0-10, 20, 50, 100, (normal), 200, 0-500, 1000, 2000ppm |
|
O2 oxygen |
0-5%, 25%, 30% (Regular), 50% VOL |
|
EX may have natural gas |
0-100% LEL (normal) |
|
N2 nitrogen gas |
0-100%. Vol (often) |
|
NH3 ammonia gas |
0-50, 100ppm (normal), 200, 500, 1000, 2000, 5000ppm |
|
CL2 chlorine gas |
0-10 (normal), 20, 50, 100, 200, 500 ppm |
|
VOC Total Volatile Organic Gas Detector |
0-2、10、50、100、200、1000、2000、6000、10000PPM |
|
H2 hydrogen gas |
0-500, 1000 (normal), 2000, 5000, 10000, 20000, 40000 ppm |
|
CH2O formaldehyde |
0-10 (normal), 20, 50, 100, 500, 1000ppm |
|
O3 ozone |
0-1, 5, 10, 20, 50 (normal), 100, 200, 500, 1000ppm |
|
CO2 carbon dioxide (infrared) |
0-1000, 2000 (normal), 5000, 10000, 50000ppm |
|
CO2 carbon dioxide (infrared) |
0-10%、20%、50%、100%Vol |
|
NO nitric oxide |
0-100, 0-250 (normal), 500, 1000, 2000, 4000ppm |
|
NO2 Nitrogen dioxide |
0-20 (normal), 50, 100, 500, 1000, 2000, 4000ppm |
|
NOX nitrogen oxides |
0-20 (normal), 50, 100, 500, 1000, 2000, 4000ppm |
|
SO2, sulfur dioxide |
0-10, 20, 100 (normal), 150ppm, 200, 1000, 2000 ppm |
|
ETO epoxyethane |
0-10 (normal), 20, 50, 100ppm |
|
Ethylene oxide ETO |
0-500、1000ppm |
|
PH3 phosphine |
0-10 (normal), 20, 50, 100, 1000, 2000, 3000, 5000ppm |
|
HCL hydrogen chloride |
0-10 (normal), 20, 50, 100ppm |
|
HCN hydrogen cyanide |
0-10 (normal), 20, 50, 100ppm |
|
COCL2 phosgene |
0-1ppm (normal) |
|
CLO2 chlorine dioxide |
0-1, 10 (normal), 20, 50ppm |
|
SiH4 silane |
0-10, 50ppm (normal) |
|
F2 fluorine gas |
0-1 (normal), 10ppm |
|
HF hydrogen fluoride |
0-10 (normal), 50ppm |
|
HBr hydrogen bromide |
0-10, 50 (normal), 100ppm |
|
B2H6 diborane |
0-5, 10, 50ppm (normal) |
|
AsH3 arsine |
0-1, 10 (normal), 50ppm |
|
GeH4 Germanane |
0-1ppm (normal) |
|
N2H4 hydrazine, hydrazine |
0-1ppm (normal) |
|
THT tetrahydrothiophene |
0-100ppm, 0-50mg/m3 (normal), 0-100mg/m3 |
|
Br2 bromine gas |
0-5, 10 (normal), 50ppm |
|
C2H2 acetylene |
0-100ppm (normal) |
|
CS2 carbon disulfide |
0-100% LEL, 50ppm (normal) |
|
C3H3N acrylonitrile |
0-10, 20 (normal), 50, 100ppm |
|
CH3COOH ethyl acetate |
0-10、20p、 50, 100 (normal), 500, 1000ppm |
|
C2H4 ethylene |
0-10 (normal), 20, 50, 100, 500, 1000ppm |
|
CH3OH methanol |
0-50, 100 (normal), 500, 1000ppm |
|
C2H5OH ethanol |
0-10, 50, 100 (normal), 500, 1000ppm |
|
CH4S Methyl Thiol |
0-20 (normal), 50ppm |
|
C2H3Cl vinyl chloride |
0-50, 100ppm (usual) |
|
Chloromethane (monochloromethane, dichloromethane, etc.) |
0-50、100ppm |
|
C8H8 styrene (electrochemical) |
0-50、200、1000、10000ppm |
|
Styrene (PID) |
0-100 (normal), 200, 1000, 6000ppm |
|
Total volatile organic compounds (TVOC) PID |
0-1,10,50PPM, (High precision, high resolution 0.001PPM) |
|
Total volatile organic compounds (TVOC) PID |
0-100 (normal), 2001000, 6000, 10000ppm |
|
Bromomethane (CH3Br) (PID photoionization) |
0-100 (normal), 2001000, 10000PPM |
|
Bromomethane (CH3Br) (electrochemical) |
0-50100 (normal), 2001000ppm |
|
C6H6 benzene (PID photoionization) |
0-1, 10, 50PPM (high precision, high resolution 0.001PPM) |
|
C6H6 benzene (PID photoionization) |
0-100 (normal), 2001000, 600010000ppm |
|
Toluene (PID photoionization) |
0-1, 10, 50PPM (high precision, high resolution 0.001PPM) |
|
Toluene (PID photoionization) |
0-100 (normal), 200,1000, 6000, 10000ppm |
|
Xylene (PID photoionization) |
0-1, 10, 50PPM (high precision, high resolution 0.001PPM) |
|
Xylene (PID photoionization principle) |
0-100 (normal), 2001000, 600010000ppm |
|
Total volatile organic compounds (TVOC) electrochemistry |
0-10,50,100PPM |
|
C6H6 benzene (electrochemical) |
0-10,50,100PPM |
|
Toluene (electrochemical) |
0-10,50,100PPM |
|
Xylene (electrochemical) |
0-10,50,100PPM |
|
The ranges listed in the above table are conventional ranges and are not included in the list. If you need to test, please consult our sales personnel Jinggong Instrument provides you with comprehensive technical support and after-sales service! Details consultation: WeChat Same Account
|
|