Ion chromatography sample pretreatment column

NegotiableUpdate on 12/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The ion chromatography sample pretreatment column is applied in the detection of food, environment and other fields, mainly to remove high concentrations of interfering ions in the sample, and can also remove impurities that have a destructive effect on the chromatography column in the sample
Product Details
Ion chromatography sample pretreatment columnThe following principles should be followed.

When using manual sample pretreatment, in order to provide necessary pressure to the sample pretreatment column, a 5mL sized syringe should be used.

In order to remove trace ionic pollutants from the sample pretreatment column and pretreat the column packing, the sample pretreatment column should be rinsed with deionized water or other appropriate solvents according to the appropriate volume listed in Table 2 before use.

In order to optimize the treatment effect of the column bed, the sample solution should be passed through the sample pretreatment column at the recommended flow rate in Table 2. For the sample pretreatment process based on adsorption principle, the column bed of the pretreatment column can only be effectively utilized when the flow rate of the sample solution is less than 4.0 mL/min; For the sample pretreatment process based on ion exchange principle, the column bed of the pretreatment column can only be effectively utilized when the flow rate of the sample solution is less than 2.0 mL/min. When the amount of sample solution processed is less than the large capacity, the sampling speed can be appropriately increased.

Whether dealing with sample solutions or standard solutions, the initial effluent should be discarded and not used. For example, after adding the sample solution into a 5mL syringe, the early 3mL of effluent should be discarded, and the remaining 2mL of effluent should be collected for injection for ion chromatography determination.

If the substance to be removed is colored material or other visible material to the human eye (such as AgCl precipitation), the sample pretreatment column can be used until there is a color band extending to 3/4 of the distance from the outlet of the sample pretreatment column. In certain special application cases, if a large loading capacity of the pre-treatment column is desired, the sample solution can be continuously passed through the pre-treatment column and tested using appropriate detection methods until column penetration is observed.

The pretreatment column of ion chromatography samples should be used vertically to achieve ideal results for sample pretreatment.

Product Introduction:

The AnLPreIC series tandem ion chromatography sample pretreatment column is made of high-purity materials, seamlessly sealed with precision molds, and utilizes the principles of reverse phase adsorption and ion exchange to efficiently remove specific directional interfering substances for analysis and detection, effectively improving detection accuracy while also fully extending the service life of the chromatography column.

Technical Indicators:

Shell: Medical grade polypropylene

Screen plate: high-purity sintered polyethylene

² Sealing: Seamless sealing of precision molds

Packing: spherical 40-50um macroporous resin/high-capacity ion exchange resin

Ion residue: ppb level

1. Ordering Information

Item Number name Specifications purpose
AnL Pre IC-H H-shaped 1cc/2.5cc,50 支/pk Removing alkaline earth metal ions, transition metal ions, and carbonate ions from the sample matrix, and also used to neutralize the strong alkalinity of the sample solution
AnL Pre IC Na type 1cc/2.5cc,50 支/pk Remove transition metal ions and alkaline earth metal ions from the sample.
AnL Pre IC-Ag Ag型 1cc/2.5cc,50 支/pk Remove from the sample solution Cl-、Br-、I-、AsO43-、CrO42-、CN-、MoO42-、PO43-、SeO32-、SeCN-、SO32-、S2-、SCN- And WO42 plasma.
AnL Pre IC-Ag/H Ag/H hybrid type 1cc/2.5cc,50 支/pk
AnL Pre IC-Ag/Na Ag/Na hybrid type 1cc/2.5cc,50 支/pk
AnL Pre IC-Ba Ba type 1cc/2.5cc,50 支/pk Remove sulfate ions from the sample.
AnL Pre IC-Ba/H Ba/H type 1cc/2.5cc,50 支/pk
AnL Pre IC-Ba/Na Type Ba/Na 1cc/2.5cc,50 支/pk
AnL Pre IC-RP RP type 1cc/2.5cc,50 支/pk Remove hydrophobic compounds, especially unsaturated and aromatic compounds, with a pH range of 0-14.
AnL Pre IC-C18 C18 type 1cc/2.5cc,50 支/pk Remove hydrophobic compounds within the pH range of 2-8.
AnL Pre IC-Ag/Ba/H Ag/Ba/H 2.5cc, 50 pieces/pk Remove from the sample solution Cl-、Br-、I-、AsO43-、CrO42-、CN-、MoO42-、PO43-、SeO32-、SeCN-、SO32-、S2-、SCN- And WO42- and SO42-


2. Application legend

2.1 Ag column removal effect

图片1.jpg

5.3

图片2.jpg