- Phone
-
Address
No. 96, Huilongguan Life Science Park, Changping District, Beijing, China
Beijing Haixinrui Technology Co., Ltd
No. 96, Huilongguan Life Science Park, Changping District, Beijing, China
Laser particle size analyzer
1: Principle

Adopting the internationally recognized Mie scattering principle and converging light Fourier transform optical path. The high-density probe and seamless full range connection testing method ensure the accuracy and repeatability of the test results.
The wet circulation dispersion system ensures that there is no particle deposition during the particle testing process, and there is no accumulation of waste liquid after testing drainage, ensuring the accuracy of the second test and making the test results more authentic and reliable;Wet intelligent laser particle size analyzerAt the same time, a pipeline residue free design was adopted to ensure the accuracy of testing different samples. The optical path automatic calibration system highlights the advantages of HL5500.
2: Technical features
One basic characteristic
⑴ Optical path design: HL5500 adopts converging light Fourier transform testing technology to obtain a large range at a short focal length, changing the resolution of the instrument; The detection unit gives HL5500 the ability to test small particles.
⑵ Fiber semiconductor laser: HL5500 adopts Japanese Opnext fiber semiconductor laser.
⑶ Japanese Canon lenses: HL5500 uses Japanese Canon lenses, while HL5100 uses domestically produced lenses.
⑷ Automatic testing: Automatic testing, what you are doing is putting in the sample, no interference data, no need to manually select data.
⑸ Ultrasonic anti dry burning function: HL5500 can achieve ultrasonic anti dry burning function, avoiding damage to ultrasound in the absence of water.
⑹ SOP self editing function: In order to meet the testing needs of different samples, HL5500 has implemented SOP self editing function, which can edit different testing processes according to different samples. After one editing and saving, it can be directly retrieved and used the next time.
⑺ Dustproof and shockproof design: The instrument has been sealed as a whole, changing the service life of internal components. The shockproof structure can avoid the interference of external vibrations on the instrument, making the test results stable and reliable.
⑻ Automatic alignment of optical path: The automatic alignment system consists of a stepper motor, guide rail, controller, and software system, with a small step size of 1 micron, allowing the laser beam * * to pass through the middle point of the detector, improving the accuracy and repeatability of the test results. The automatic centering system is a standard configuration for all models of Haixinrui laser particle size analyzers.
Two technological advantages
⑴ Strong anti-corrosion design (optional): Acid resistant, alkali resistant, oil resistant, and organic solvent resistant (including some organic solvents) can be equipped according to the actual needs of customers.
⑵ Microcirculation system: The entire decentralized circulation system has been optimized and designed (with microscale testing as an option).
⑶ Bubble free design: The entire test avoids bubbles entering the test sample window, avoiding bubble interference.
⑷ Dew point measurement function: The system is equipped with a dew point measurement function, and the software can provide sample window fogging reminders according to changes in the environment; The instrument has the function of displaying internal temperature, humidity, and test medium temperature simultaneously.
⑸ Automatic dispersant injection system: HL5500 has added an automatic dispersant injection system, greatly improving the stability of instrument dispersion; Not only does it avoid the tedious process of manual addition, but it also greatly extends the cleaning cycle of the sample window
Sample residue free design: The instrument pipeline and drainage structure have been optimized, and there is no residual liquid accumulation in the instrument pipeline and circulation pump to avoid affecting the next test data.
⑺ Sample window quick change device: The sample window quick change device makes sample window replacement more convenient and fast.
3: Technical parameters
| Specification Model | HL5200 | HL5500 | HL6100 | HL6100-Plus |
| execution standard | ISO 13320-2020;GB/T19077-2024 | |||
| test scope | 0.1-800um | 0.01-1000um | 0.01-2000um | 0.01-2800um |
| accuracy | <0.5% (D50 value of standard sample) | <0.5% | <0.5% | <0.5% |
| repetitiveness | <0.5% (D50 value of standard sample) | <0.5% | <0.5% | <0.5% |
| Laser parameters | Imported fiber output high-power laser with λ=635nm, p>10mW (optional 20mW) | |||
| optical path alignment | Automatic calibration of optical path | |||
| Dispersion method | Ultrasonic frequency | Circulation and mixing | rotation speed | sample pool |
| f=40KHz, Power: p=80W | integrated design | 0-4000rpm speed adjustable Adopting dust-proof and shockproof design | Boiling type | |
| Adjustable at will; Equipped with ultrasonic anti dry burning feature | 190-600mL | |||
| volume | 850mm*410mm*450mm | 1050mm×320mm×335mm | ||
| weight | 30Kg | 46Kg | ||
moreWet intelligent laser particle size analyzerPlease contact pre-sales for technical specifications
4: Technological upgrade
㈠The use of filter lens dual lens technology ensures the measurement accuracy of the instrument.
㈡The wet circulation dispersion system adopts a pipeline residue free design to ensure no particle deposition during particle testing.
Three JoinLaser intelligent management system ensures the lifespan of the laser.
㈣Enhance the instrument's misoperation protection function,Reduced the damage caused to equipment by improper human operation.
5: Software functions
① Software function: The analysis modes include free distribution, R-R distribution, lognormal distribution, and graded statistical mode, which meet the different requirements of different industries for the statistical methods of the measured sample particle size.
② Statistical methods: volume distribution and quantity distribution, to meet different statistical methods for particle size distribution in different industries.
③ Statistical comparison: It is possible to conduct statistical comparative analysis on multiple test results, which can significantly compare the differences in test results between different batches of samples, samples before and after processing, and test results at different times. This has practical significance for industrial raw material quality control.
④ DIY by oneself: Users can customize the data to be displayed, calculate percentages based on particle size, and calculate particle size based on percentages.
⑤ Display template: Calculate the percentage of particle size range to meet the characterization requirements of different industries for particle size testing. Distance, consistency, interval accumulation, and so on.
⑥ Test report: The test report can be exported in various forms such as Word, Excel, images (Bmp), and text (Text) to meet the needs of viewing test reports in different situations and citing test results in scientific research articles.
⑦ Multi language support: Supports both Chinese and English language interfaces, and can also embed interfaces in other languages according to user requirements.
⑧ Intelligent operation mode: automatic unmanned intervention operation, no human interference, you only need to follow the prompts to add the test sample.
⑨ Operation mode: One click automatic software operation mode.
⑩ Test speed:<1min/time (excluding sample dispersion time).
6: Application Fields
|
| nanomaterials | Used to study the influence of particle size on material properties of metal oxides, metal powders, and ceramic materials. |
|
| Biomedicine | Analyze proteins DNA、RNA、 The granularity of viruses and various antigen antibodies. |
|
| fine chemicals | Used to search for the particle size distribution of catalysts to reduce chemical reaction temperature and increase reaction rate. |
|
| paint and coating | It is used to measure the particle size of paint, coating, silica gel, polymer latex, pigment, ink, water/oil lotion, toner, cosmetics and other materials. |
|
| Food and Drug | Coating nanoparticles on the surface of drugs can slow down their release and make them into targeted drugs, which can be used to measure the particle size of the coating material in order to better exert the therapeutic effect of drugs. |
|
| aerospace | Adding metal powder to rocket solid propellants can significantly improve the combustion performance of the propellant and can be used to study the particle size distribution of metal powder. |
|
|
National Defense Science and Technology | Refractory materials increase the efficiency of converting electromagnetic energy into thermal energy, thereby making electromagnetic wave absorbing materials and improving their absorption performance of electromagnetic waves. Materials with different particle sizes have different optical properties and can be used to study the performance of absorbing materials. |
7: Test report

8: Some typical users
| serial number | User List | Specification Model | Year of Purchase |
| 1 | Tsinghua University | TW180-C | 2021 |
| 2 | Hainan University | HL2020-C | 2021year |
| 3 | Southern University of Science and Technology | HL6100-C | 2021year |
| 4 | Quanzhou Meteorological Bureau, Fujian Province | TW180-C | 2022year |
| 5 | Jiangsu Xiuqiang Glass Craft Co., Ltd | HL5100 | 2022year |
| 6 | Sichuan Mabian Longtai Phosphorus Power Co., Ltd | HL5100 | 2022year |
| 7 | Sichuan Xingtai Pule Medical Technology Co., Ltd | HL6100-C | 2022year |
| 8 | Shandong Agricultural University | HL3100 | 2023year |
| 9 | Jiangxi University of Science and Technology | HL2020-B | 2023year |
| 10 | Beijing Lepu Medical Equipment Co., Ltd | HL6100-C | 2023year |
| 11 | North China University of Technology | HL2020-L | 2023year |
| 12 | Wuhan Tianna Technology Co., Ltd | HL5500 | 2024year |
| 13 | Hefei University | HL3100 | 2024year |
| 14 | Ningde Times New Energy Technology Co., Ltd | TW180-A | 2024year |