Intelligent dust and toxin sampler

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

JCC-3000A intelligent dust and toxin sampler is a dual-purpose sampler that can collect both dust and toxins. This instrument is equipped with dual pumps that work independently to collect dust and toxic substances without interfering with each other. The intelligent operation platform is built on an intelligent and standardized internal management system, with menu settings that can record the last sampling time, continuous sampling, intermittent sampling, intelligent power management, timely display of battery level, charging indication, and efficient imported hollow cup motor drive.

Product Details

1、 Product Introduction

JCC-3000A typeIntelligent dust and toxin samplerIt is a dual-purpose sampler that can collect both dust and toxic substances. This instrument is equipped with dual pumps that work independently to collect dust and toxic substances without interfering with each other. The intelligent operation platform is built on an intelligent and standardized internal management system, with menu settings that can record the last sampling time, continuous sampling, intermittent sampling, intelligent power management, timely display of battery level, charging indication, and efficient imported hollow cup motor drive.JCC-3000A typeIntelligent dust and toxin samplerhaveThe large LCD screen display and timed shutdown without operation make it an ideal and practical dust and toxin dual-use sampler among similar instruments in China.
2、 Product parameters
1. Sampling flow range: 0.1-1.5L/min (toxic)
5.0~30L/Min (dust)
2. Flow error: ≤ 2.5 level
3. Timing error: ≤± 1 ‰
4. High negative pressure: ≥ 15000Pa
5. Charging current: 300mA (standard type)
6. Power supply: 10V · DC, 220V 50Hz · AC
7. Working temperature: -25~45 ℃
8. Noise: ≤ 60dB
9. Relative humidity: ≤ 85%
10. Volume: 200 × 160 × 140mm
3、 Configuration List
1 instrument box
1 safety bottle
1 sampling head
2 absorption bottle racks
2 sampling clips
1 continuous hose
Tripod 1 set
1 power cord
1 box of filter membrane
1 copy of instruction manual

Juchuang Environmental Protection provides you with comprehensive technical support and after-sales service!

Operation and Maintenance

1. Install the sampling head with filter membrane clamp for dust collection, press the "on/off" button for two seconds to enter the power on screen, press the "cancel" button to enter the "function settings", use the up and down keys to enter the "sampling mode settings" or "system function settings". If the sampling mode setting is selected, press "confirm" and then press the "left" and "right" keys to select continuous sampling or intermittent sampling (usually continuous sampling), and press the "up" and "down" keys to select the sampling time and stop time (in intermittent sampling mode). It is recommended to shut down the system if there is no operation setting within 1-3 seconds. The backlight time should be around 5 seconds. After setting, press the "Cancel" button to enter the "Confirm" sampling time. After setting the menu once, the next time you turn it on, simply press the "Power On" button and select the desired time, then press "Confirm" to start sampling.

2. Charging: The display screen of the instrument shows the battery capacity. This graphic indicates full charge, and when the graphic indicates undervoltage, it needs to be charged. When charging, simply connect the battery cable to AC mains and connect it continuously with the sampler for fully automatic charging. The indicator light of the charging completed host has changed from red to green.

3. Attention: If the battery is not used for more than 3 months, it should be recharged to ensure the service life of high-energy cadmium nickel batteries.

In air with high dust content, a sampling head with a filter membrane should be installed before starting up, otherwise dust particles entering the machine will affect the cleanliness of the air path components.