E-mail
info@hioki.com.cn
- Phone
-
Address
Room 4705, Raffles Plaza, 268 Xizang Middle Road, Huangpu District, Shanghai
Rizhi (Shanghai) Measurement Technology Co., Ltd
info@hioki.com.cn
Room 4705, Raffles Plaza, 268 Xizang Middle Road, Huangpu District, Shanghai
|
CAT III 600V |
![]() |
|
Safely, accurately, and quickly measure the insulation resistance of PV
● Can safely and accurately measure the insulation resistance of PV during the day
● Equipped with PV specific function, measuring time of 4 seconds
Insulation resistance measurement with 5 ranges
Voltage measurement DC1000V, suitable for open circuit voltage inspection of 1000V PV systems
Compare its functions
Anti fall design for concrete floor at a height of 1m

Introduce the PV Ω measurement function that can stably measure the insulation resistance of PV in power generation, and display a video of the specific steps for using it.


The IR4053-10, specially designed for measuring insulation resistance of solar panels, is not affected by power generation and can accurately measure insulation resistance values.

According to the two measurement methods specified in the JEM-TR228 guidelines of the Japan Electric Machinery Industry Association, as well as the issues with previous insulation resistance meters
Measurement method without short circuit
The risk is relatively low, and depending on the state of the circuit, it may be affected by PV during power generation, which may result in measurement results that are different from the actual insulation resistance state.
Measurement method for short circuit
In order to accurately measure PV in power generation, it is necessary to perform short-circuit measurements on the measurement circuit.
Additional short-circuit switches need to be installed, which may pose risks and hazards.
Moreover, to prevent potential hazards, it is generally recommended to conduct measurement work at night.

The measurement method without short circuit usually involves measuring the insulation resistance when it becomes unstable after insulation measurement, and then measuring it when it becomes PV Ω.
Can accurately measure without being affected by solar panels.

After the measurement starts, the measurement values will be displayed on four sides.
After the first display, update the display value every 1 second.
Quick measurement, convenient and comfortable usage.

After setting the standard value, a value above the standard value is considered PASS, and a value below the standard value is considered FAIL.
When determining FAIL, a continuous beep sound and a red light on the display screen will be used to notify.
Therefore, the results of qualification are clear at a glance.

It can be operated with just the thumb.
Press the switch to measure words, and turn on the switch for continuous measurement.
The picture shows an analog megohmmeter

By using a test line with a switch, measurement can be started and stopped at the test line.
There is also a small light at hand for easy operation in the dark.

The anti drop design that can withstand a drop of 1 meter from concrete is reassuring even for on-site use.