F2000-IType infrared oil analyzer Technical parameters: Wave number scanning range: Wave number repeatability:± Wave number accuracy:± Spectral resolution: Accuracy:±2% Repeatability: (relative standard deviation):<2% Linear range of absorbance:0.0000~1.9999 Correlation coefficient:r>0.999(Infrared Non Dispersive Method) Basic measurement range:0.1~800mg/L(Directly measure the oil content in the extraction solution),No dilution required) Minimum detectable concentration:0.001mg/L(Enrichment)100Oil concentration in double water Maximum detectable concentration:80000mg/L(Dilution measurement) detection limit3SD:<0.1mg/L Baseline drift:1%/4h Measurement errors for different ratios:<5%(Configure different proportions of mixed hydrocarbon measurement) Compliant with standards: fully compliant with national standards for water quality, determination of petroleum and animal and vegetable oils Infrared photometry method“GB/T16488 Fully comply with the national food fume emission standards“GB18483 External dimensions:722×391×201(mm) Weight: Power Supply:220V±10V 50Hz±1Hz 40W Connection method: AdoptingUSB2.0/RS-232Interface connection to desktop or laptop computer Main features (accuracy, stability, innovation, intelligence, multifunctionality) Good stability: adopting an integrated optical path system with unique optical path design, long optical path, high energy, strong signal, and high signal-to-noise ratio. Aluminum alloy casting base, with small deformation, good stability, and no drift. Accurate positioning: Imported stepper motors are used to drive the wavenumber scanning mechanism for wavenumber positioning and scanning, ensuring that the wavenumber positioning and scanning accuracy are less than one wavenumber. Reference measurement: using a unique dual cell automatic switching mechanism between sample and reference cell, precise positioning, reduced errors, and accurate measurement; Unaffected by external environmental changes, achieve automatic zeroing. Compliant with national standards: fully compliant with national standards“GB/T16488 True three wave number: fully considering the joint influence of alkanes, cycloalkanes, and aromatic alkanes, it can adapt to the determination of mixed hydrocarbons with various composition ratios, avoid the problem of "standard oil", and has great advantages. It does not rely on "standard oil" for hydrocarbon composition ratios and truly scans“3030-1、2960-1、2930 Small measurement error: The determination error of various hydrocarbon composition ratios is less than 5%, fully demonstrating the instrument's unique adaptability to changes in hydrocarbon composition in the sample. Truly serving actual water samples, respecting objectivity and authenticity, and never falsifying. Easy to operate: completely detached from computer operation, user-friendly interface, Chinese menu,LCDLarge screen display and print output. It can also be done throughUSB2.0perhapsRS232Interface for desktop or laptop computer operation. Guide operation, simple operation, no need to make standard curves, no need to adjust zero points, no need to adjust full-scale, no need to build platforms, no need to calibrate. Directly display the measurement results. Powerful features: Three wavenumber infrared photometry, non dispersive infrared method, catering fume measurement menu, fully in accordance with national catering fume emission standards(GB18483-2001)Measure the concentration of cooking fume emissions in the catering industry. Spectral scanning function, in order to meet the needs of scientific research departments, can also be used for analyzing material structure and qualitative and quantitative analysis. Easy maintenance: Non professional maintenance, good stability, no need for frequent calibration, easy to use. Instrument configuration:F2000-Ihost, Widely applicable in various fields Environmental monitoring department: determination of substances in groundwater, surface water, industrial wastewater, and domestic sewage; Traffic environment monitoring, railway environment monitoring station, marine environment monitoring, agricultural environment monitoring station, municipal drainage monitoring station Water purification, sewage treatment plants; External drainage from petroleum refining and petrochemical industries; Measurement of oil fume emissions in the catering industry; Steel enterprise environmental monitoring station, industrial and mining enterprise monitoring station, thermal power plant monitoring station; Research institutions; |