Industrial grade multi toxic smoke concentration analyzer

NegotiableUpdate on 01/01
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The testo340 industrial grade multi toxic flue gas concentration analyzer can also measure the concentrations of conventional gases such as O2, CO, NO, NO2, SO2, as well as related flue gas temperature, flow rate, flow rate, energy efficiency, etc. It has the following characteristics: $r $n1, for ultra-low concentration gas conditions, CO low and NO low sensors can be optionally equipped to achieve more accurate measurement. $r$n2, For the concentration of NO2 gas in the working condition flue gas, users can choose to use NO2 sensors for measurement according to their needs, or obtain it through automatic empirical calculation based on the NO2 conversion coefficient and NO sensor measurement value in the firmware.
Product Details

Industrial grade multi toxic smoke concentration analyzerTechnical Specifications

size 283 x 103 x 65 mm

Operating temperature -5 ~ +50 °C

storage temperature -20 ~ +50 °C

shell TPE PC

Protection level IP40

display size 160 x 240 pixels

Display screen characteristics graphic display

power supply Rechargeable battery pack3.7 V / 2.4 Ah; Power supply 6.3 V/2 A

Maximum smoke negative pressure -200 mbar

Maximum positive pressure of flue gas 50 mbar

User defined fuel 10 types of user-defined fuels, including standard gases

Hose length The longest to7.8 m (by connecting an extension hose)

pump flow rate 0.6 l/min (constant control)

Maximum memory 100 folders

Each folder Maximum capacity10 measurement points

Each address Maximum capacity200 sets of data

other The maximum number of data that can be accommodated depends on the number of folders or measurement points

data transmission Bluetooth ®; USB port

weight 960 g

SOmeasurement(Anti CO interference 10000ppm)

measurement range 0 ~ 5000 ppm

measurement accuracy ±4 ppm (0 ~ 79 ppm)

± 5% measurement value (other ranges)

resolution 1 ppm

response time < 30 s

   

To avoid adsorption, it should not exceed the maximum lengthA measurement duration of 2 hours.

Pull force measurement

measurement range -40 ~ +40 hPa

measurement accuracy ±0.03 hPa (-2.99 ~ +2.99 hPa)

± 1.5% measurement value (other ranges)

resolution 0.01 hPa

   

temperature

measurement range -40 ~ +1200 °C

measurement accuracy ±0.5 °C (0 ~ +99 °C)

±0.5% measurement value (other ranges)

resolution 0.1 °C

   

Validity determination

measurement range 0 ~ 120 %

resolution 0.10%

   

Smoke loss

measurement range 0 ~ 99.9 %

resolution 0.10%

   

Dew point calculation of flue gas

measurement range 0 ~ 99.9 °Ctd

resolution 0.1 °Ctd

   

COmeasurement(Through O)calculate)

measurement range 0 ~ COmax

measurement accuracy ±0.2 Vol.%

resolution 0.1 Vol.%

response time < 40 s

differential pressure

measurement range -200 ~ 200 hPa

measurement accuracy ±0.5 hPa (-49.9 ~ 49.9 hPa)

±1.5% measurement value (other ranges)

resolution 0.1 hPa

   

Absolute pressure

measurement range +600 ~ +1150 hPa

measurement accuracy ±10 hPa

resolution 1 hPa

   

Omeasurement

measurement range 0 ~ 25 Vol.%

measurement accuracy ±0.2 Vol.%

resolution 0.01 Vol.%

response time < 20 s

   

CO measurement (H)compensation)

measurement range 0 ~ 10000 ppm

measurement accuracy ± 10 ppm ± 10% measured value (0~200 ppm)

±5% measurement value (other ranges)

resolution 1 ppm

response time < 40 s

   

CO low (Hcompensation)

measurement range 0 ~ 500 ppm

measurement accuracy ±2 ppm (0 ~ 39.9 ppm)

±5% of the measured values (other ranges) are taken from an ambient temperature of 20 ℃. Extra temperature coefficient 0.25% measured value/K

resolution 0.1 ppm

response time < 40 s

   

NO measurement

measurement range 0 ~ 4000 ppm

measurement accuracy ±5 ppm (0 ~ 99 ppm)

±5% measurement value (other ranges)

resolution 1 ppm

response time < 30 s

   

NOlow measurement

measurement range 0 ~ 300 ppm

measurement accuracy ±2 ppm (0 ~ 39.9 ppm)

±5% measurement value (other ranges)

resolution 0.1 ppm

response time < 30 s

   

NOmeasurement

measurement range 0 ~ 500 ppm

measurement accuracy ±5 ppm (0 ~ 99.9 ppm)

±5% measurement value (other ranges)

resolution 0.1 ppm

response time < 40 s

To avoid adsorption, it should not exceed the maximum lengthA measurement duration of 2 hours.

Industrial grade multi toxic smoke concentration analyzer1200 ° C industrial flue gas sampling probe set, suitable for testo 340 and testo 350, can be used to sample high-temperature flue gas (<1200 ° C), and can also be used to sample flue gas at large diameter sampling points.

lNon heated sampling tube, can be connected up toTwo extended sampling tubes, with a total length of up to 3m.

lThermocouple(2.2m) can be installed in a 2m long sampling tube for measuring smoke temperature.

lPre filter, which can be installed at the end of the sampling tube, is used for sampling high dust content flue gas.

The product includes:

lNon heating handle

l1200 ° C non heated sampling tube

lNon heated sampling hose, including dust filter

lType K thermocouple