E-mail
chinainfo@fesks.com.cn
-
Phone
13795339399
-
Address
2nd Floor, Building A, No. 135 Yinyu Road, Jiading District, Shanghai
Fisker Instruments (Shanghai) Co., Ltd
chinainfo@fesks.com.cn
13795339399
2nd Floor, Building A, No. 135 Yinyu Road, Jiading District, Shanghai
FESKS/Fisker imports FOSTCO 5000 P from the UKImported online phenolphthalein alkalinity analyzerIt is an online analyzer that automatically determines water quality parameters based on colorimetric titration. Adding reagents to water samples can cause color reversal
Should. Based on the indicator used, the device evaluates the intensity of the color. Calculate the concentration of phenolphthalein alkalinity in water by observing the color change of the sample during reagent addition.
Application: Industrial and boiler water, groundwater, and other natural water.
Application: Industrial and boiler water, groundwater, and other natural water.
Product Features:
→ Reliable, accurate, and fully automatic analyzer
→ Monitor two programmable limit values
→ Perform simple debugging through the configuration wizard
→ Automatic calibration, automatic diagnosis, and automatic measurement
Compact design, easy to maintain and clean
Multi language, multi-color LED display
Relay output of error message
→ Analog output 0/4-20 mA, digital output RS 485
→ Digital input for initiating analysis, flow switch, or interval reset
Measurement data storage and measurement data protocol on SD card
Update software through SD card
FESKS/FOSTCO 5000 P imported from the UKOnline phenolphthalein alkalinity analyzerThere are two versions:
Wall mounted analyzer
The analyzer consists of a controller and a measurement chamber. Both are installed on a bracket on the same wall. This version is fully functional, including connections for inlet and outlet, as well as a bracket for holding reagent bottles.
Shell analyzer
For wall mounted analyzers, there is a plastic casing that can be used to use the analyzer in locations where pollution is expected to be more severe. The analyzer on the wall mount can be quickly installed in the housing with 4 screws. If the analyzer is ordered together with the casing, the device is already installed in the casing.

Technical Specifications
|
value/scope |
measurement method |
Titration colorimetric method(Titration of color change |
measurement range |
0.2-5 mmol/L、0.8-20 mmol/L |
measurement accuracy |
The ± value is 5% of the maximum reading of the reagents used separately |
Repetitive accuracy |
The ± value is 2.5% of the maximum reading of the reagent used |
Reagent consumption |
approximately0.05-0.6ml/Analysis depends on the measured concentration of phenolphthalein alkalinity in the water quality |
analysis cycle |
Continuous measurement interval measurement(5-360min)/external control |
Measurement duration |
approximately3min,Based on the alkalinity of phenolphthalein in water quality and the set flushing time |
Analysis frequency |
500Milliliter reagent softened water can perform 10000 analyses |
water consumption |
about 1 L/ 2 barBelow analysis,The water consumption varies according to the inlet pressure and the set flushing time |
relay output |
4Road relay, maximum load 250V 4A (alarm, pre alarm, fault, missing indication, analysis contact) |
signal input |
2One input, maximum load 18V 12mA, stop or start analysis |
analog output |
0-20mA/4-20 mAResolution:<100 μ A, max.750 Ω |
digital output |
RS 485 Modbus RTUagreement |
power supply voltage |
100-240 VAC(50/60 Hz),24V AC/DCoptional |
power consumption |
25W(Running), 8 W measuring, 3.5W (standby) |
load capacity |
terminal1The load capacity of a relay with an internal current of 1A up to 4. The load capacity of an external power supply is 2.5 A |
size/weight |
No shell:274x275x129mm(WxHxD)About 2kg with shell: 332x345x190mm (WxHxD) about 4kg |
Storage temperature |
0°C-45℃ |
ambient temperature |
10°C-45 ℃ |
Measure water temperature |
5°C-40℃ |
Protection level |
Wall opening installationIP43,Installed in the box IP56 |
Water quality requirements: General water inlet: pressure min: 0.5 bar - max: 5 bar/recommended 1-2 bar, transparent, no solids, no bubbles, no odor
Water quality requirements for measuring phenolphthalein alkalinity in water: pH:<8.2
FOSTCO 5000 P online phenolphthalein alkalinity analyzer ordering information
Order number and model description
60-5000-30 Fostco 5000 P online phenolphthalein alkalinity analyzer
200920/200921 P720/P730 supporting reagents: 0.2-5 mmol/l (500ml), 0.8-20 mmol/l (500ml)