option |
option |
|
![]() |
||
|
|
|||||
Fastest 0.5ms, high-speed and highly stable measurement, saving space by half the rack size
Measurement frequency: 1MHz~300MHz
Measurement time: fastest 0.5ms
Basic accuracy ± 0.72% rdg
The compact host is only half the size of a rack, and the test head is only the size of a palm
Rich contact inspection functions (DCR measurement, Hi-Z screening, waveform determination)
● Use the analysis function to measure while scanning and measuring frequency and signal level
The host does not come with a testing fixture. We need to use a dedicated test fixture for impedance analyzer IM7580A.

It is possible to infer the constants of five equivalent circuit modes based on measurement results. Moreover, the ideal value of frequency characteristics can be displayed through simulation function, using speculative results or any constant. In addition, using the comparator function can also determine whether the measurement result is within the judgment area.

The measurement frequencies of the IM7580 series 5 models cover 1MHz to 3GHz.
Combined with the testing fixture IM9201 for 6 sizes of SMD, it can measure samples simply and accurately.

In the comparator function of the analysis mode, it can determine whether the measured value has entered any set judgment area. The "zone determination function" is to set the range of upper and lower limits and display the determination result in IN/NG.

In the comparator function of the analysis mode, it can determine whether the measured value has entered any set judgment area.
The "peak determination function" sets the range based on the above limit, lower limit, left limit, and right limit, and displays whether the measured peak is within the determination area in IN/NG.

In the comparator function of the analysis mode, it can determine whether the measured value has entered any set judgment area.
The "SPOT determination function" selects any scanning point and parameter, and can determine up to 16 points.

By using the comparator function, it is possible to determine whether the measured value has entered any set judgment area.
Applicable to the function of determining whether the sample is qualified.

By using the contact inspection function, it is possible to check the contact status between the sample and the measuring port, and confirm the poor contact and connection status.

Connect the connection wire of the test head to the impedance analyzer.
Slightly bend the handle of the torque wrench and tighten the nut (0.56 N · m).
Please be careful not to twist it too far.

Simply input numerical values to easily calculate accuracy.
Impedance analyzer accuracy calculation software, please click