Used to measure the insulation resistance of high-voltage equipment (transformers, cables, motors, etc.)
● Wide testing voltage range: 250 V~5 kV
● Wide measurement range, maximum 10 T Ω
Automatic calculation and display of insulation judgment index
● Data storage function that can reduce handwritten recording work
Communication options: Wireless and USB compatible
● Small and lightweight, standard with IP65 compliant hard box
1: -25 ℃~40 ℃ (below 80% RH), 40 ℃~45 ℃ (below 60% RH), 45 ℃~50 ℃ (below 50% RH)
2: When using alkaline dry batteries, 5 kV occurs, there is an open circuit between the positive and negative terminals, the backlight is turned off, the comparator is turned off, and the reference value is 23 ° C
| measurement project | Insulation resistance measurement, leakage current measurement, voltage measurement, electrostatic capacitance measurement (DD function) |
|---|---|
| Maximum rated voltage between terminals | AC 1000 V、DC 2000 V |
| Maximum rated voltage to ground | 1000 V(CAT IV)、2000 V(CAT III) |
| Temperature and humidity range for use | -20 ° C to 50 ° C ※ 1 (no condensation) |
| Save temperature and humidity range | -25 ° C to 65 ° C, below 80% RH (no condensation) |
| Dustproof and waterproof properties | IP40 (with protective shell, excluding terminal part) IP65 (C0212 carrying case) |
| Applicable standard | EN 61010 (safety), EN 61326 (EMC), IEC 61557-1, IEC 61557-2 (insulated megohmmeter) |
| power supply | 5 alkaline dry battery (LR6) x 8, nickel hydrogen rechargeable battery (HR6) x 8 |
| Continuous usage time ※ 2 | About 5 hours (without Z3210 installed), about 4 hours (with Z3210 installed and wireless communication) |
| Volume and mass | 195 (W) × 254 (H) × 89 (D) mm, approximately 1.7 kg (including battery) |
| Attachment | Test lines L9850-01 × 1, L9850-02 × 1, L9850-03 × 1, Crocodile clip L9851-01 × 1, Crocodile clip L9851-02 × 1, Crocodile clip L9851-03 × 1, Carrying case C0212 × 1, 5 # alkaline dry battery (LR6) × 8, User manual × 1, Precautions for use × 1 |
| Insulation judgment function | PI, DAR, DD, SV, Ramp, Timer |
|---|---|
| Other functions | Battery effective value range display, live warning display, automatic power saving, automatic discharge, backlight, buzzing, data storage operation record, data storage save record, temperature and humidity input, time display, clock function, filter, hardware filter, hold function, system restart, USB communication function (only applicable when installing DT4900-01), wireless communication (only applicable when installing Z3210), comparator, bar chart, insulation judgment function switching, fault function |
| Output voltage range | DC 250 V~5.20 kV | ||||
| Set resolution | 250 V~1 kV:10 V steps、1 kV〜5 kV:25 V steps | ||||
| Rated measurement current | 250V | 500V | 1000V | 2500V | 5000V |
| Accuracy guarantee range (1) | 0.00 MΩ〜2.50 GΩ ±5% rdg ±5 dgt | 0.00 MΩ〜2.50 GΩ ±5% rdg ±5 dgt | 0.00 MΩ〜10.0 GΩ ±5% rdg ±5 dgt | 0.00 MΩ〜25.0 GΩ ±5% rdg ±5 dgt | 0.00 MΩ〜50.0 GΩ ±5% rdg ±5 dgt |
| Accuracy guarantee range (2) | 2.51 GΩ〜500 GΩ ±20% rdg | 5.01 GΩ~1.00 TΩ ±20% rdg | 10.1 GΩ~2.00 TΩ ±20% rdg | 25.1 GΩ~5.00 TΩ ±20% rdg | 50.1 GΩ~10.00 TΩ ±20% rdg |
| rated current | 1 mA〜1.2 mA | ||||
| short-circuit current | Below 2 mA | ||||
| Measurable frequency | More than 200 times | ||||
| Range (automatic range) | 10 nA | 100 nA | 1000 nA | 10 μA | 100 μA | 1 mA |
|---|---|---|---|---|---|---|
| display range | 0.00nA ~ 9.99 nA | 9.0 nA ~ 99.9 nA | 90 nA ~ 999 nA | 0.90 μA〜9.99 μA | 9.0 μA〜99.9 μA | 90 μA〜999 μA※1 0.90 mA〜3.00 mA※2 |
| resolution | 0.01 nA | 0.1 nA | 1 nA | 0.01 μA | 0.1 μA | ※1: 1 μA ※2: 0.01 mA |
| Accuracy guarantee | AC 30 V〜1000 V(45 Hz〜65 Hz) DC ±10 V〜±2000 V |
|---|---|
| precision | ± 3% rdg. ± 3dgt. |
| Input resistance | Above 500 k Ω (DC, 45 Hz~65 Hz) |
| Overload protection | AC 1100 V (between positive and negative terminals within 1 minute) DC 2200 V (between positive and negative terminals within 1 minute) |
precision |
± 10% rdg ± 5 nF (accuracy guarantee range: 10.0 nF~25.0 µ F) |
||
range |
100 nF |
1000 nF |
10 μF |
display range |
0.0 nF ~ 99.9 nF |
100 nF ~ 999 nF |
1.00 μF ~ 9.99 μF※1 |
resolution |
0.1 nF |
1 nF |
※1: 0.01 μF |