E-mail
info@ika.cn
-
Phone
18026312739
-
Address
173-175 Youyi Road, Guangzhou Economic and Technological Development Zone
Aika (Guangzhou) Instrument Equipment Co., Ltd. (IKA/Aika, Germany)
info@ika.cn
18026312739
173-175 Youyi Road, Guangzhou Economic and Technological Development Zone
CBC VISC liteHaving a wider temperature control range-25℃ - 125℃Specially designed for viscosity
Born from measurement, can be combined withIKA ROTAVISCViscometer adaptation.
Product advantages
› Save time:Can be placed simultaneously 2 a600 mlThe beaker is used for sample temperature control
› Effect:Optimized circulating water bath management strategy to achieve fast and accurate temperature control.
More emphasis on environmental protection:Equipped with environmentally friendly natural refrigerantsR 290.
› Flexible application: CBC VISC liteIt can also be used through pump connectors forDIN,ELVASWaiting for the clamp
Sample temperature control of adapter set
› Easy to maintain:The air filter can be easily disassembled and cleaned to ensure excellent performance
| Viscosity measurement range | 6000000 mPas |
| Viscosity accuracy (FSR) | 1 % |
| Viscosity repeatability (FSR) | 0.2 % |
| Spring torque | 0.0673 mNm |
| guardrail | lo-vi |
| Measure the number of spindle stages | SP set-1 |
| Motor output power | 4.8 W |
| overload protection | yes |
| rotation direction | right |
| display screen | TFT |
| Speed display | TFT |
| speed range | 0.01 - 200 rpm |
| Speed setting accuracy | ±0.01 rpm |
| speed control | TFT |
| Torque display | yes |
| Torque measurement | yes |
| timer | yes |
| Timer display | TFT |
| Time setting range | 0.017 - 6000 min |
| Temperature measurement accuracy | 0.1 K |
| Working temperature display | TFT |
| External temperature sensor interface | PT 100 |
| Graphic function | yes |
| Operation mode | Timed, continuous operation |
| Calibration Options | yes |
| Jogging function | yes |
| Allow density | 9999 kg/dm3 |
| Zui low working temperature | -100 - 300 °C |
| Bracket fixation | Extend arm clamp fixation |
| Support rod diameter (including integrated fixed bracket) | 16 mm |
| Lift bracket travel | 200 mm |
| Plug connection (Ø) | 12 mm |
| Bottom container volume | 600 ml |
| support | Rotastand |
| maximum stroke | 61 mm |
| diameter | 16 mm |
| dynamic load | 5 kg |
| Overall dimensions | 351 x 629 x 372 mm |
| weight | 7.1 kg |
| Allow ambient temperature | 5 - 40 °C |
| Allow relative humidity | 80 % |
| DIN EN 60529 Protection Methods | IP 40 |
| RS 232 interface | yes |
| USB port | USB-B |
| voltage | 100 - 240 V |
| frequency | 50/60 Hz |
| Instrument input power | 24 W |
| Instrument input power standby | 1.6 W |
| DC voltage | 24 V= |
| Current consumption | 1000 mA |