Welcome Customer !

Membership

Help

Suzhou Heli Automation Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Suzhou Heli Automation Technology Co., Ltd

  • E-mail

  • Phone

  • Address

    No. 1555 Greenland Avenue, Zhongke Innovation Plaza, Kunshan City, Suzhou City, Jiangsu Province

Contact Now

IDEC and Izumi button switch

NegotiableUpdate on 05/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Suzhou Japanese IDEC and Izumi distributor: Determine the number of different buttons according to the needs of the control circuit, such as single button, double button, triple button, multi button, etc. For example, when three types of controls are required: "forward", "reverse", and "stop", three buttons can be used and installed in the same button box; When only "start" and "stop" controls are needed, two buttons are assembled in the same button box.

Product Details

Suzhou Japan IDEC and Izumi distributor product usage instructions:
(1) According to different usage scenarios and specific purposes: Select the type of button based on the usage scenario, such as open, protective, waterproof, anti-corrosion, etc; Choose the appropriate form according to the purpose, such as handle rotation, key type, emergency type, illuminated type, etc. For example, the general buttons on the console cabinet surface can be opened first; If it is necessary to display the working status, use an indicator light type; In very important areas, it is advisable to use a key type to prevent unauthorized personnel from operating it incorrectly; Corrosion resistant materials should be used in areas with corrosive gases.
(2) Select the color of buttons and indicator lights according to the requirements of work status, instructions, and work conditions: green is used to indicate "start" or "power on", and red is used to indicate "stop". In addition, the voltage of the indicator light (bulb) is divided into several types such as 6.3V, 12V, 24V, etc.
(3) Determine the number of different buttons according to the needs of the control circuit, such as single button, double button, triple button, multi button, etc. For example, when three types of controls are required: "forward", "reverse", and "stop", three buttons can be used and installed in the same button box; When only "start" and "stop" controls are needed, two buttons are assembled in the same button box.
(1) The button should be checked regularly to remove any dirt on it. Due to the small distance between the contacts of the button, after years of use or poor sealing, dust or oil emulsions of various stages can flow in, causing insulation reduction and even short circuit accidents. For this situation, insulation and cleaning treatment must be carried out, and corresponding sealing measures must be taken.
(2) When buttons are used in high-temperature environments, they can easily cause plastic deformation and aging, leading to button loosening and causing short circuits between wiring screws. According to the situation, a fastening ring can be added during installation to tighten it, or an insulated plastic tube can be added at the wiring screw to prevent loosening.
(3) The button with indicator light is prone to deformation of the plastic lampshade over time due to the heat generated by the bulb, making it difficult to replace the bulb. Therefore, it is not suitable for use in places with long power on time; If you want to use it, you can lower the voltage of the light bulb appropriately to extend its service life.
(4) If poor contact is found, the cause should be identified: if there is damage to the contact surface, it can be repaired with a fine file; If there is dirt or cigarette ash on the contact surface, it is advisable to wipe it clean with a clean cotton cloth dipped in solvent; If the contact spring fails, it should be replaced; If the contact is severely burned, the product should be replaced.

Suzhou Japan IDEC and Izumi distributor
RJ series thin power relay PCB terminal type:
RJ1V-C-A12,RJ1V-C-A24,RJ1V-C-A110,RJ1V-C-A115
RJ1V-C-A120,RJ1V-C-A220,RJ1V-C-A230,RJ1V-C-A240,RJ1V-C-D5,RJ1V-C-D6
RJ1V-C-D12,RJ1V-C-D24,RJ1V-C-D48,RJ1V-C-D100,RJ1V-A-A12,RJ1V-A-A24
RJ1V-A-A110,RJ1V-A-A115,RJ1V-A-A120,RJ1V-A-A220,RJ1V-A-A230,RJ1V-A-A240
RJ1V-A-D5,RJ1V-A-D6,RJ1V-A-D12,RJ1V-A-D24,RJ1V-A-D48,RJ1V-A-D100,RJ1V-CH-A12
RJ1V-CH-A24,RJ1V-CH-A110,RJ1V-CH-A115,RJ1V-CH-A120,RJ1V-CH-A220
RJ1V-CH-A230,RJ1V-CH-A240,RJ1V-CH-D5,RJ1V-CH-D6,RJ1V-CH-D12
RJ1V-CH-D24,RJ1V-CH-D48,RJ1V-CH-D100,RJ2V-C-A12,RJ2V-C-A24
RJ2V-C-A110,RJ2V-C-A115,RJ2V-C-A120,RJ2V-C-A220,RJ2V-C-A230
RJ2V-C-A240,RJ2V-C-D5,RJ2V-C-D6,RJ2V-C-D12,RJ2V-C-D24,RJ2V-C-D48
RJ2V-C-D100,RJ2V-A-A12,RJ2V-A-A24,RJ2V-A-A110,RJ2V-A-A115
RJ2V-A-A120,RJ2V-A-A220,RJ2V-A-A230,RJ2V-A-A240,RJ2V-A-D5
RJ2V-A-D6,RJ2V-A-D12,RJ2V-A-D24,RJ2V-A-D48,RJ2V-A-D100