Horiba conductivity meter conductivity meter HE-200C ESH-001

NegotiableUpdate on 05/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Horiba conductivity meter HE-200C ESH-001 is used to measure the conductivity and temperature of water samples. $r $n $r $n outdoor on-site installation, different from the panel installation of HE480C. According to USP lt;645 The quality guide is applicable for monitoring the recovery control of pure water/boiler drainage and online measurement of pharmaceutical water conductivity.

Product Details

On site installation type conductivity meterHE-200C ESH-01-C-S-ST-Y

Four wire transmission, low concentration

Horiba conductivity meter conductivity meter HE-200C ESH-001Measure the conductivity and temperature in the water sample.

Outdoor on-site installation, different from panel installation of HE480C. According to the USP<645>quality guidelines, it is suitable for monitoring the recovery control of pure water/boiler drainage and online measurement of pharmaceutical water conductivity.

range

Conductivity: 0-2000 μ s/cm, 0-200.0 ms/cm
(TDS 0 ~ 2000 mg/L)
Temperature: 0~100 ℃

sturdy

  • Dealing with harsh conditions during on-site measurement.
    Operating temperature range (transmitter): -20~55 ℃
    Rated power supply voltage: AC 100~240 V ± 10% 50/60 Hz
    Aluminum alloy watch box: protection level IP65

  • Compliant with CE marking and FCC rules, suitable for use on overseas sites.

Horiba conductivity meter HE-200C ESH-001 best-selling model;

host:HE-200C

Split electrode:ESH-001-C-S-ST-Y、ESH-01-C-S-ST-Y

Integrated electrode:ESH-001-L-S-ST-Y-10、

Flow pool:EFA-30、EFA-30-P、

Split cable:CK-10M




intelligence

  • Convenient function to display liquid temperature simultaneously (transmission output available).

  • Respond to various types of temperature compensation.

  • The self diagnostic function can immediately detect sensor errors.

  • Environmentally friendly (lead-free) design that can handle WEEE and RoHS.

  • Rich interfaces (2-channel transmission output, compatible with RS-485, 3-contact output).

easy to maintain

  • Easy to view large display screen.

  • Easy to operate.

  • Can store calibration records.

  • Use thread terminals in the wiring board that will not come off for wiring



parameter


measurement method

Dual electrode communication method

range

(Conductivity measurement and TDS conversion cannot be selected simultaneously)

*Range only applicable to hygiene grade sensors (FS-01 series)

Electrode constant

/cm

0.01

0.1

1

conductivity

uS/cm

0.000~2.000
0.00~20.00

0.000~2.000
0.00~20.00
0.0~200.0
0~2000*

0.0~200.0
0~2000

mS/cm

0.0000~0.2000
0.000~2.000

0.0000~0.2000
0.000~2.000
0.00~20.00
0~200.0*

0.00~20.00
0.0~200.0

TDS conversion

mg/L

0.00~2.00
0.0~20.0

0.0~20.0
0~200

0~200
0~2000

temperature

℃

0~100 resolution: 0.01 ℃

repetitiveness

Conductivity: ≤± 0.5% F.S. TDS conversion: ≤± 1.5% F.S
Temperature: ± 0.1 ℃ (or equivalent input)

linear

Conductivity: ≤± 0.5% F.S. TDS conversion: ≤± 1.5% F.S
Temperature: ± 0.5 ℃ (or equivalent input)

Transfer output

2-4 mA DC input/output insulation type maximum load impedance 900 Ω
Output range 1: Conductivity: arbitrarily set within the measurement range
Output range 2: Temperature: can be set arbitrarily within the range of -10-160 ℃
Abnormal output: Fault state (3.8mA or 21mA)
Keep function: can be set to: current value hold, any value hold

Contact output

3-point no voltage contact output relay contact SPDT (1c)
Contact function: R1, R2: upper limit alarm, lower limit alarm, USP judgment, output signal retention optional
FAIL: Fault alarm
Output content: conductivity (or TDS conversion value), temperature

Contact input

one o'clock
Contact form: collector open circuit, no voltage, contact a
Contact function: external input for transmission output holding

communication function

RS-485 2-wire type, input/output insulation type (transmission output is non insulated)

temperature compensation

Range: 0~100 ℃ (extended and calculated for temperatures below 0 ℃ and above 100 ℃)

ambient temperature

-20~55℃

Temperature compensation component

Pt1000(0℃)

Correction function Conductivity: Correction coefficient for input electrode constant (parameter input)
TDS conversion value: based on specified coefficients (0.30-1.00) conversion
Temperature: 1-point calibration compared to the reference thermometer

Self-diagnostic function

Sensor diagnostic error, transmitter malfunction

power supply

100~240 V AC 50/60 Hz
Power consumption: 15 W or lower

construction

Outdoor installation type: IP65 protection level
Installation method: 50A column or wall installation
Shell material: Aluminum alloy
Installation fixing and protective cover material: SUS304

weight

About 4.5 kg

Electrical certification

CE marking,FCC rules

Applicable electrodes

ESH and FS series conductivity sensors (electrode constants of 0.01/cm, 0.1/cm, 1.0/cm)




Electrode selection ESHSplit style

horiba电导仪电导率计HE-200C ESH-001