The JTM-KBR6 household combustible gas detector (hereinafter referred to as the detector) is made of high-quality gas sensing components, combined with advanced electronic technology and sophisticated processes. In places where gas or carbon monoxide is present, once the gas concentration or carbon monoxide concentration reaches the alarm set value, the JTM-KBR6 detector will emit an audible and visual alarm signal to remind you to take effective measures immediately: or activate the linkage device, ventilate or turn off the gas source, eliminate the danger, and effectively avoid the occurrence of malignant accidents such as fire, explosion, poisoning, etc. caused by gas leakage.
Supports NB-IOT and CAT1 communication methods.
New national standard products, fire protection, complete inspection report certificates;
*Equipped with battery backup function, it can be used for 5-7 hours in case of power failure;
*Simultaneously detecting methane and carbon monoxide gas leaksAdapt to various application scenarios;
Beautiful appearance, LCD display, capable of displaying time and concentration values;
Voice alarm and voice prompt, user-friendly interaction;
NB module communication, platform interaction, can adapt to various IoT functions;
Support power failure reporting, valve status feedback, etc;
The household gas alarm R2 is suitable for various occasions such as homes, schools, shops, factories, hotels, etc.
| model | JTM-KBR6 |
| sensor type | Semiconductor type, electrochemical type |
| gas detection | CH4 (methane), Co (carbon monoxide) |
| Working Voltage | AC 220 V±15% |
| power consumption | <1.6W |
| Usage environment | Temperature: -10 ℃~55 ℃;
Humidity: ≤ 93% RH without condensation; Atmospheric pressure: 86 kPa~106 kPa; Indoor use type |
| response time | CH4:30; Co: ≤ 60 automatic recovery |
| sampling method | Natural diffusion |
| range | CH4:0~20%LEL;
CO: 0~500 × 106 (volume fraction) |
| Alarm setting value | CH4 : 10%LEL;
CO: 150 × 10-6 (volume fraction) |
| alarm method | Sound and light alarm, voice broadcast |
| Alarm Volume | >70dB |
| Sensor lifespan | 5 years |
| weight | About 170g |
| Overall dimensions | L×b×h,101 mm×58 mm×43 mm |
| Shell protection level | Shell protection level IP 30 |
| Optional features | Gas shut-off valve |