High voltage transformer for power frequency withstand voltage test

NegotiableUpdate on 05/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The high-voltage transformer terminal of the power frequency withstand voltage test is located on the box cover, avoiding collisions and improving mechanical and electrical performance. The product has the characteristics of compact structure, stable electrical performance, sufficient capacity, small size, light weight, and easy use and maintenance.

Product Details

Brief introduction

YDJ typePower frequency test transformerThe edge of the box avoids oil leakage. The terminal post is placed on the box cover, avoiding collisions and improving mechanical and electrical performance. The product has the characteristics of compact structure, stable electrical performance, sufficient capacity, small size, light weight, and easy use and maintenance.

High voltage transformer for power frequency withstand voltage testDetailed introduction of specifications and models

Characteristics of power frequency test transformer products:

1. Adopting an axisymmetric equilateral octagonal shell structure; Can output dual high voltage.

2. The oil level in the tank is lower than the edge of the tank, avoiding oil leakage.

3. The terminal post is placed on the box cover, avoiding collisions and improving mechanical and electrical performance.

4. The product has the characteristics of compact structure, stable electrical performance, sufficient capacity, small size, light weight, and easy use and maintenance.

Keywords: power frequency test transformer, power frequency withstand voltage generator, power frequency high voltage generator, test transformer

1. Operating System:

XZC series operation box: Capacity: 1KVA-5KVA, Input voltage: 0.22KV

KZT series console: Capacity: 10K/A-300KVA Input voltage: 0.22KV, 0.38KV

2. Protective digital microampere meter SWB-II

3. Resistance capacitance AC/DC voltage divider FYQ-50, 100, 150, 220KV

4. High voltage DC discharge * * FZ-70, 140, 210KV

5. High voltage silicon stack: 2DL-150, 300, 450KV

6. Insulation bracket 50, 100, 200, 300KV

7. High voltage filtering capacitor 0.01UF, 40-100KV

8. Equal pressure ball

9. Protecting Ball Gap: Q-50, 100, 150, 200, 250, 500

10. Standard oil test cup 400ml

11. Medium oil cup

12. Folding trolley models 150 and 300

13. Water resistance

14. High voltage tester 10KV, 35KV

15. High Voltage Phaser 10KV, 35KV/110KV, 220KV

16. Various multimeters, megohmmeters, and test wires

High voltage transformer for power frequency withstand voltage testProduct Parameters:

Input voltage: AC220 (380) V ± 10% 50Hz ± 1

Output voltage: AC 0-250 (430) V

◆ Output high voltage: 0-500kV

Output current: 0-1000mA

Output capacity: 0-500kVA

◆ Timing range: 0-999S

◆ Environmental temperature: -20 ℃ to 50 ℃

Voltage accuracy ≤ 1% (F.S)

Current accuracy ≤ 1% (F.S)

technical indicators

1. Environmental requirements for the use of test transformers:

1.1 Input voltage: AC 220V or 380V, 50Hz;

1.2 Environmental temperature: -40 ℃ to 40 ℃;

1.3 Relative humidity: ≤ 85% (when the ambient temperature is 25 ℃);

1.4 In an environment free from chemical gases and vapors;

1.5 In non explosive gases;

1.6 In situations where rainwater does not infiltrate.

Power frequency withstand voltage test transformeroperating steps

1. Connect the leads according to the wiring schematic and reliably ground the transformer and control box;

2. Before the experiment, check whether the wiring of each part is in good contact and whether the voltage regulator of the control box is adjusted to the 'zero' position;

3. Connect the power supply, the green indicator light will turn on. Press the start button, and the red indicator light will turn on, indicating that the transformer has been powered on and is waiting for voltage to increase;

4. Rotate the regulator handle clockwise at a constant speed to increase the pressure, and pay close attention to the instrument indication and the condition of the test sample;

5. After the experiment is completed, the voltage should be quickly reduced to zero and the stop button should be pressed, then the power should be cut off and the test lead should be disconnected.