- Phone
-
Address
Yunfeng Building, No. 31, East Section of South Second Ring Road, Beilin District, Xi'an City
Xi'an Xiaxi Electronic Technology Co., Ltd
Yunfeng Building, No. 31, East Section of South Second Ring Road, Beilin District, Xi'an City
1. Product Introduction
Developed based on the cycle analysis methodVLE1000High voltage phase balance testerBy using a liquid-phase circulation pump to force two-phase flow to achieve system equilibrium, it is possible to measure the phase equilibrium parameters of high-pressure systems within the range of 01-4 MPa; Sampling and analysis of gas-liquid two-phase samples can be achieved by connecting chromatography instruments, which have the advantages of high temperature measurement accuracy, wide pressure measurement range, and accurate measurement; By combining self-developed programs, automatic temperature control, automatic pressurization, automatic sampling, and data analysis can be achieved. It can be used to test the gas-liquid phase equilibrium of various pure and binary/ternary systems, and is suitable for measuring the phase equilibrium of low boiling point refrigerants and their mixtures.
2. Main features
lHigh temperature control accuracy:Temperature fluctuation less than ± 0.05 ℃ to ensure experimental stability;
lAccurate temperature measurement:The temperature measurement accuracy reaches 0.02 ℃, ensuring the reliability of temperature data;
lAccurate pressure measurement:Using high-precision pressure sensors, the measurement uncertainty of the pressure sensor is less than 0.04% FS;
lWide temperature measurement range:Suitable for measurement within the temperature range of -30~60 ℃;
lWide pressure measurement range:Pressure range of 0.1~4 MPa, supporting customization for higher pressures;
lHigh degree of automation:It can achieve automatic temperature control, automatic temperature measurement, automatic pressure measurement, and data processing;
lAutomatic sampling:It can achieve high-precision quantitative sampling analysis with multiple injections, short experimental time, and stable experimental results.
3. Technical parameters
1)Measurement principle: Single liquid phase circulation analysis method
2)Measurement temperature: -30~60 ℃
3)Pressure range: 0.1~4MPa
4)Temperature measurement accuracy: better than ± 0.02 ℃
5)Temperature control fluctuation: ± 0.05 ℃
6)Sample dosage: 60 mL
7)Scope of application: Pure, binary, and ternary systems
8)Measurement values: four parameters of equilibrium state: temperature T, pressure p, liquid phase mole fraction x *, gas phase mole fraction y *
9)Expansion testing: expandable to obtain gas-liquid equilibrium phase diagram, vapor pressure, boiling point
10)Data transfer: USB
11)Working environment: 0-40 ℃, 65% RH
12)Power supply: 220 V, 50 Hz
4Scope of application
VLE1000 high voltagePhase balance testerMainly suitable for low boiling point refrigerants or mixed refrigerants, chemical reagents, chemical products, etcMeasurement of gas-liquid equilibrium parameters in a 60 ℃ system.