Welcome Customer !

Membership

Help

Yongjia Liangke Valve Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Products

Yongjia Liangke Valve Co., Ltd

  • E-mail

  • Phone

  • Address

    Dongou Industrial Zone, Oubei Town, Yongjia County, Zhejiang Province

Contact Now

High temperature and high pressure solenoid valve

NegotiableUpdate on 05/23
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

High temperature solenoid valve is a pilot direct acting solenoid valve with a wide range of universal media, which can be used for fluids such as water, light oil, heavy oil, non corrosive gases, and steam. It is mainly used in the drainage system of power station exhaust pipelines and the exhaust system of evaporators to perform dual position automatic adjustment and remote control of the media in the pipelines. High temperature and high pressure solenoid valve

Product Details

Detailed information:

High temperature solenoid valveIt is a pilot direct acting solenoid valve with a wide range of universal media, which can be used for fluids such as water, light oil, heavy oil, non corrosive gases, and steam. It is mainly used for dual position automatic adjustment and remote control of the media in the pipeline, such as the drainage system of power station extraction pipelines and the exhaust system of evaporators.

High temperature solenoid valveModel specification description

IIIHigh temperature solenoid valvecharacteristic

High temperature resistance: using metal hard sealing to increase the operating temperature.

Wear resistant: The material selection is reasonable, and the valve cup and guide sleeve cleverly utilize the lubrication effect of the fluid to reduce wear.

4High temperature and high pressure solenoid valvestructural principle

1. Structure as shown in the diagram

2High temperature solenoid valveworking principle

When the electromagnetic iron of the solenoid valve is energized, the connecting rod is lifted, which drives the shaft to rotate and opens the auxiliary valve. Due to the opening of the auxiliary valve, the pressure fluid in the upper part of the main valve cup is discharged, so the pressure in the lower part of the main valve cup is higher than that in the upper part, which pushes the main valve cup upwards. After the main valve is opened, the upper and lower pressures are equal, and the valve cup is placed in a balanced state under the action of electromagnetic force and upper and lower pressure, and the valve is opened. When the power is cut off, under the self weight of the armature and the action of the return spring, the auxiliary valve is closed. After the auxiliary valve is closed, the pressure on the upper part of the main valve cup rises and presses the main valve cup down, achieving the function of cutoff sealing, and the valve is closed.

五、 ZCZG、ZCZHHigh temperature solenoid valveTechnical Specifications

Medium temperature ℃

ZCZG

≤250

ZCZH

≤400

Nominal pressure
(MPa)

ZCZG

2.5

ZCZH

4.0

Work pressure difference
(MPa)

ZCZG

0.1~2.5

ZCZH

0.1~4.0

Nominal Diameter
(mm)

10

15

20

25

32

40

60

65

80

100

power consumption

0.15KVA

0.46KVA

0.15KVA

power supply voltage

Other specifications of AC220V can be ordered for special purposes

Rated flow coefficient
(KV)

According to JB/T7352-94 regulations

Leakage rate (m/min)

According to JB/T7352-94 · F regulations

六、 ZCZG、ZCZHHigh temperature solenoid valveOverall dimensions

DN

L

H

D

D1

D2

D3

b

f1

f

n-d

10

160

298

90

60

34

41

16

4

2

4-Φ14

15

160

298

95

65

39

45

16

4

2

4-Φ14

20

200

304

105

75

50

55

16

4

2

4-Φ14

25

200

304

115

85

57

65

16

4

2

4-Φ14

32

200

314

140

100

65

78

18

4

2

4-Φ18

40

260

460

150

110

75

85

18

4

3

4-Φ18

50

300

460

165

125

87

100

20

4

3

4-Φ18

65

290

433

185

145

109

120

22

4

3

8-Φ18

80

310

433

200

160

120

135

22

4

3

8-Φ18

100

350

461

235

190

149

160

24

4.5

3

8-Φ22

7High temperature solenoid valveInstallation Instructions

1. When installing, the solenoid valve coil should be facing upwards and kept in a vertical position. The arrow or mark on the solenoid valve should be aligned with the flow direction of the pipeline, and should not be installed in areas with splashing or leaking water.

2. The working medium of the solenoid valve should be clean and free of particulate impurities. The dirt and filters on the surface of the solenoid valve components should be cleaned regularly.

3. In order to isolate the solenoid valve in a timely manner and ensure the normal operation of the system when it malfunctions, a bypass device (as shown in Figure 1) is installed.

4. In the pipeline system, the diameter of the solenoid valve installed on the branch should be smaller than that of the main pipeline valve (as shown in Figure 2).

5. Before installing the solenoid valve, the pipeline must be cleaned thoroughly. It is recommended to install a filter in front of the valve and a drain valve in the steam pipeline.

6. The solenoid valve should not be installed in a low concave part of the pipeline to avoid hindering its operation due to steam condensation, impurities, etc. settling inside the solenoid valve.

7. Electromagnetic valves should not be used in explosive hazardous environments.

8. In the case of insufficient rigidity of the pipeline, it is recommended to fix the pipeline in front of the solenoid valve with a bracket to prevent vibration caused by the operation of the solenoid valve.

9. Before installation, it is important to carefully read the electromagnetic valve product label, carefully read the user manual, and determine whether the product meets the usage conditions.

10. Pressure gauges need to be installed on the pipelines before and after the solenoid valve to observe the pipeline pressure.

8、 Electromagnetic valve usage and maintenance

1. It is recommended that the user unit assign a dedicated person to be responsible for use and maintenance.

2. After the installation of the solenoid valve, it needs to be tested several times with the medium and confirmed to be normal before it can be put into formal use.

3. Regularly clean the dirt inside and outside the valve and the suction surface, and be careful not to damage the sealing surface.

4. When the solenoid valve is not in use for a long time, the manual valve in front of the valve should be closed. When it is restarted, the steam solenoid valve should drain the condensed water and perform several trial operations. It can only be put into use after the switch is normal.

5. When the solenoid valve is removed from the pipeline and not in use, the interior and parts should be wiped clean and stored with compressed air.

6. When used for a long time, if the sealing between the piston and the valve seat is not good, the sealing surface of the piston can be re ground flat and then ground with the valve seat.

7. When working, pay attention to the pressure gauges before and after the valve, and ensure that the working pressure does not exceed the rated pressure. The working pressure difference must be within the rated pressure difference range. When the working pressure exceeds the rated pressure or the working pressure difference exceeds the rated pressure difference, the solenoid valve should be stopped and the front and rear manual valves should be closed to prevent the solenoid valve from exploding and leaking.

9、 Notice for Ordering Electromagnetic Valves

1. When ordering solenoid valves, please specify the model, nominal diameter, nominal pressure, working medium, working pressure difference, medium temperature, power supply voltage and frequency, and medium viscosity.

2. The voltage of the solenoid valve during normal operation is 220

+22

V, If it exceeds this range, please indicate the voltage fluctuation when placing an order. Other specifications of power supply voltage can be specially ordered.