OneHigh precision capacitive thin film vacuum gauge VR-208C-510D (E)Overview:
PBS-510xx-C1typeThe capacitive thin film vacuum gauge is a PBS-510 series thin film vacuum gauge productmodelone of(For the full range of product models and classifications, please refer to the appendix.)1)Its main feature is the accuracy levelcompareHighMeasurement repeatabilityOkay, use DB15D cableSocket (wire position and MKS600)Series, etcThe thin film vacuum gauge is the same canalternative use).PBS-510xx-C1typeCapacitive thin film vacuum gaugeIn terms of measurement mechanism, it has the advantages of good linearity of traditional capacitor film gauges, and the measurement value is independent of the composition of the measured gas; From its structure, it adopts a new generation ofMCUDigital chip devices are intelligent digital vacuum sensors.PBS-510xx-C1typeCapacitive thin film vacuum gaugenot only canoutputMultiple standardsAnalog signal,stillcanTo haveRS-485MODBUS、HART and other protocolsData communication interfaceOptional for direct data communication with intelligent scientific instruments
PBS-510A/B/C/D-C1typeThin film vacuum gauge suitable for laboratory environmentMatching with precision scientific instrumentsUse, for temperature, humidity, vibrationGas pressure fluctuation rate, air cleanliness, electromagnetic interference intensity under testwaitallThere are certain requirements, and in addition, in order toguaranteeHigh precision vacuum pressure measurement, forSubsequent secondary instruments, acquisition circuit accuracy level, resolution, power supplyPower supply conditions, protective grounding wire, working grounding wireWait, technical requirementsMust comply with relevant product regulations;Therefore, before using this model of product, it is necessary to carefully read and understand this user manual.
IIStructure and installation usage
(1) Structure:
The appearance of PBS-510x-C1 thin film vacuum gauge is shown in Figure 1: 3.↓
1. Shell;
KF-16 vacuum quick release flangeinterface; 1→ ↓ ←6
3. D15 socket;
4. S-full adjustment hole;4 5
5. Z-zero adjustment hole;
6. Secure the nut.
(2) Installation
1. Avoid using in environments with strong vibrations and electromagnetic interference.
The equipment needs to have a good working ground wire (grounding resistance)<20~25 ohms);
The equipment casing is well grounded(Protecting ground wire); 2→
2. capacitanceThin film vacuum gauge Should be installed in a vertical position (as shown in the figure)
When the device must be installed in a horizontal or other angular position
It is necessary to recalibrate the angle and correct the additional errors caused by it.Figure 1 PBS-510xx-C1typeThin film vacuum gauge
3. Vacuum connection standard configurationadoptNW16 ISO-KF(i.e. KF-16)Vacuum quick release flange, with supporting parts available
KF-16 welded flange made of 304 stainless steel material, along with clamps, center brackets, and O-ring rubber seals、Connect to equipment pipelines or containers by welding flange heads. Pay attention to checking the welding quality of the flange, the smoothness and cleanliness of the flange end face and sealing ring during installation, and ensure good vacuum sealing and stable and firm installation.
(3)Electrical connection:
1.High precision capacitive thin film vacuum gauge VR-208C-510D (E)The electrical connection uses D15 type 15 pin high reliability connectors, with a standard power supply voltage of ± 15Vdc; electric current:<35mA; Three wire system; Output signal: 0-10VDC, connected to the power supply voltage ground. As shown in the following figure:;
use±15When using VCD power supply, the wiring terminals are as follows:
d7-------+15VDC - Connection cable color:Red or brownColor
d6------—15VDC------Connecting cable branching color: blue
D2- Output 0-10V - Connection cable color:Yellow or graycolor
D12------- Output zero position(power supply0 bits,Connecting the outer shell - Connecting the cable, color of the branch line: black
When using a 24VCD power supply, the wiring terminals are as follows:
D7--24VDC positive pole -- Connection cable branch color: redOr brown
d6------ 。。。。。。 Negative pole - Connecting cable branch color: blue
D2- Output 0-10V - Connecting cable branch color: yellowOr gray
D12------- Output Zero Position (connected to the casing) ------- Connection Cable Distribution Color: Black
picture. 2 PBS-510xx-CElectrical Connection Instructions for Type 1 Thin Film Vacuum Gauge
(IV)Measurement calibration
PBS-510xx-CThe Type 1 thin film vacuum gauge is a high-precision measuring instrument and should be regularly calibrated. The accuracy of the standard used for verification should be higher than the accuracy level of the instrument being verified by one levelaboveIf zero calibration is required during use, it must be donecompareA high vacuum source. It is recommended not to be casual in daily lifeon one's ownAdjustment, can be sent (with this project)CNASLocal administrative metrological technical institutions that verify qualifications for calibration and calibrationAnd calibration.The recommended calibration cycle is one year.
After sales service and precautions
1.Before use, be sure to read the user manual carefully to prevent accidental operation;
2.If there is a malfunction, please contact the manufacturer in a timely manner and do not repair it without authorization to prevent human error.
3.The warranty period for the instrument is 18 months. If it exceeds the warranty period,Or intentionally damaged, or dismantled by oneself ,Need to pay for maintenance costs;
4.When connecting secondary instruments, it is necessary to have a detailed understanding of their technical performance, input impedance, and measurement resolution, which must comply with the specific technical specifications of the thin film vacuum gauge. It is recommended that the input impedance of the secondary instrument must be greater than100k~1000k ohms, measured ADtransformationThe resolution is higher than 20 bits;The external power supply voltage must meet the specific specifications of the thin film vacuum gauge, as detailed in the product technical specifications.
Main technical indicators:
measurement range:(1Tor、10Tor、100Tor、1000Tor)
measurement accuracy: 0.1 level、0.25 level
Measurement resolution:0.0001Tor、0.001Tor0.01Tor、0.1Tor
output signal:4~20mA\\\\1—5V\\\\0~10V,
impedance<600Ω;
response time:≦20ms
typicalOperating temperature range:10—50C;
power supply voltage:±15V(Standard configuration), ±12V、24V DC,
material: 304 stainless steel
Overload pressure:400kPa
appearancesize:Φ48x125mm ,
weight039kg
vacuuminterfacestandard:NW16 ISOKF(Standard)
electrical connection:15 PIN D-sub