High performance capillary electrophoresis instrument dual wavelength detector (imported from the United States) Optical path system: diffraction grating monochromator Light source: imported deuterium tungsten lamp, edge filtering, 370nm deuterium lamp, tungsten lamp automatic switching system ★ Dual wavelength detection wavelength range: 190-740nm Reagent usage is small, sample pretreatment is simple.
1、 Introduction to the configuration of high-efficiency capillary electrophoresis instrument:
Optical system: diffraction grating monochromator
Lamp source: Imported deuterium tungsten lamp, edge filtering, 370nm
★ Deuterium lamp and tungsten lamp automatic switching system
★ Dual wavelength detection wavelength range: 190-740nm
Bandwidth: Δλ≤ 8nm
Wavelength accuracy: ± 1nm
Sensitivity: 2 × 10-5AU at 254nm, t=1s
GLP function: detailed report, lighting time and frequency
Noise: 1.5 × 10-5AU
Baseline drift: 4 × 10-4AU/h
★ Detection limit: ≤ 1 × 10-5g/ml
Quantitative repeatability: RSD% ≤ 3.0%
Qualitative repeatability: RSD% ≤ 1.3%
★ Minimum length of capillary tube: 25cm
IIHigh efficiency capillary electrophoresis apparatusHigh voltage power supply parameters:
★ Output voltage range: 0-35KV continuously adjustable (standard)
Output current range: less than 0-1000 μ A
Voltage output WU difference: ≤ 0.5%
Current output WU difference: ≤ 0.5%
Time drift: ≤ 0.05%
Temperature drift: ≤ 0.05%
★ One click high voltage and data collection
Short circuit protection: self recovery protection for closed sections
Variable wavelength selection, continuously adjustable from 190-740nm
Injection method: Electric injection 0-35KV adjustable
LCD screen display, touch panel
Can perform wavelength scanning and automatically reset to zero
IIIHigh efficiency capillary electrophoresis apparatusTechnical analysis:
Working mode: fully automatic nucleic acid extraction+nucleic acid detection
Sample volume: 1-24 (80-2000 μ l), 1-96 (20-250 μ l)
Magnetic bead recovery rate:>99%
Temperature control range: from room temperature to 100 ℃
Scope of sample physical examination: 20-250 μ l
Sample addition accuracy: ± 1 μ l
Sample repeatability: coefficient of variation not exceeding 0.5%
Applicable suction head: 200, 100 μ l
Transfer channels: 8
Applicable: 96 hole plate, 96 magnetic sleeve plate, 24 hole plate, 24 magnetic sleeve plate
Mixing method: Rotating mixing
Extraction speed: 90 minutes (extraction time depends on sample type)
UV sterilization: independent UV sterilization
Serial port: COM port and USB port