High current clamp meter wireless phase analyzer

NegotiableUpdate on 05/13
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The LYWHX-9200 high current clamp meter wireless core phase meter has high and low voltage current and leakage current testing functions, with a current measurement range of 0-20000A, and can also meet core phase, current, leakage current, phase, phase sequence, and electrical verification tests; It can also be used for leakage inspection: the X detector with current testing function is hooked onto the cable and inspected along the line. If the receiver changes from displaying a large current to displaying a very small current or no current, this point is the cable leakage point.

Product Details

LYWHX-9200High current clamp meter wireless phase analyzerIntroduction

Composed of wireless receiver, hook type detector, telescopic insulation rod, etc. Hook type detectors are different from traditional phase detectors that require metal detection hooks to be connected. Instead, they adopt an integrated hook design. B-type products are also compatible with high-voltage current testing functions and can be directly hung on the circuit to test current and phase, saving time and effort. They can hook wires with a diameter of 168mm or busbars with a diameter of 168mm × 245mm; The receiver adopts a 3.5-inch true color LCD screen, which displays the nuclear phase result, current, phase, frequency, etc. on the same screen, with vector diagram indication and voice prompts such as "X signal normal, Y signal normal, in-phase, out of phase", which are clear and intuitive. The distance between open ground nuclear phases can reach up to 1600m, and it can intelligently detect voltage lines ranging from 10V to 550kV. Bare wires below 35kV can directly contact the nuclear phase, while bare wires above 35kV use non-contact nuclear phases. The non-contact nuclear phase is achieved by gradually approaching the tested wire with a hook detector. When an electric field signal is induced, the nuclear phase can be completed without directly contacting the high-voltage wire, making it more reliable! This nuclear phase analyzer has the functions of a high-voltage voltage tester, a high-voltage phase meter, and a high-voltage phase sequence meter, which can be used for electrical testing, phase sequence testing, transformer group determination, etc.

The LYWHX-9200B X detector also has high and low voltage current and leakage current testing functions, with a current measurement range of 0-20000A, and meets the requirements of nuclear phase, current, leakage current, phase, phase sequence, and electrical verification tests; It can also be used for leakage inspection: the X detector with current testing function is hooked onto the cable and inspected along the line. If the receiver changes from displaying a large current to displaying a very small current or no current, this point is the cable leakage point.

LYWHX-9200High current clamp meter wireless phase analyzerModel difference

type number

Nuclear phase distance

Nuclear phase voltage level

current range

LYWHX-9200

01600m

10V550kV

/

LYWHX-9200B

020000A

Technical Specifications

merit can

High and low voltage wireless voice core phase, current, leakage current, frequency, phase, phase sequence, and electrical testing; Multi core cable leakage inspection, etc

electricity source

DC 3.7VRechargeable lithium battery,USBCharging interface, continuous operation approximately10hour

test method

Hook type detector, which can be hung on the line or hooked onto the wire for testing

transmission method

315MHzThe433MHzwireless transmission

Nuclear phase distance

Short distance mode:0150m(Default upon startup)

Long distance mode:21600m

display mode

3.5Inch true color LCD screen display

Measurable line diameter

F168mmThe wire, or168mm×245mmMother's Row

quantity Cheng

Nuclear phase voltage level:AC 10V550kV

Phase:0.0°~360.0°

frequency45Hz75Hz

electric current:0.00A20000A(selection)

part distinguish

0.1°;0.1Hz10mA

essence degree(23℃±5℃,80%RHbelow)

Phase: ≤±10°

Frequency: ≤±2Hz

electric current:06000A,±3%±5dgt; 6000A2000A,±4%±5dgt;

Differential qualitative analysis

in-phase:30°~30°; heterogeneous: 90°~150° and210°~270°

Voice feature

In phase, out of phaseXThe signal is normalYNormal signal and other voice functions

Insulation rod size

Stretching for approximately5mAfter contraction, the length is about1m(5section)

data storage

9999group

Nuclear phase method

Contact nuclear phase:35kVThe following bare wires, or110kVThe following wires with insulated outer skin are in direct contact with the core phase.(Operating with insulated rod)

Non nuclear phase:35kVThe above bare wires, or110kVThe above circuit adopts non-contact core phase.(Operating with insulated rod)

Electrical verification indication

Detector "beep--toot--Beeping sound

change

automatic gear shifting

position error

The impact of wire position error during current testing:AThere is no positional error in the area;BArea increase0.2%CArea increase2%(See the following picture)

sampling rate

2time/second

Instrument size

Hook type detector: length, width, and thickness310mm×270mm×52mm

Receiver: Length, Width, Thickness250mm×100mm×40mm

backlight control

Press the up and down arrow keys to adjust the backlight brightness

Induction intensity control

According to the different strength of the induced electric field, the detector can automatically control the amplification factor, which is convenient for phase detection in densely populated areas

data retention

Press in test modeHOLDPress the key to hold the data, then press againHOLDKey Cancel Keep

Exit function

pressESCPress the key to exit the current function interface and return to the higher-level directory

data lookup

pressENTERAfter entering the data retrieval mode, press the arrow keys to browse through the stored data

No signal indication

Dynamic display when the receiver does not receive the transmission signal“----”Symbols

Auto Shutdown

Start up approximately15After minutes, the instrument panel will automatically shut down to reduce battery consumption

battery voltage

When the battery voltage is lower than3.2Vtime

Detector: The power indicator light flashes slowly to remind charging

Receiver: Low battery voltage symbol display, reminding to charge

rated current

Detector:35mA maxReceiver:300mA max

Instrument quality

Hook type detector:496g(Contains battery)

receiver:395g(Contains battery)

Insulation rod:1.45kg

Total mass:13.5kg(Including instrument box)

Working temperature and humidity

-10℃~40℃;80%Rhbelow

Storage temperature and humidity

-10℃~60℃;70%Rhbelow

dry disturb

No particularly strong electromagnetic field; Nothing433MHzThe315MHzco-channel interference

insulation strength

Insulation rod:AC 110kV/rms(5After the insulation rod is fully stretched, between the two ends)

Detector:2000V/rms(Between the insulation rod connector and the top of the hook type detector)

receiver:2000V/rms(Before the front and rear ends of the shell)

knot constitute

Anti drip type IIIP63

Suitable for safety regulations

GB1339892TheGB311.1311.68The3DL40891The standard and the newly issued national standard for the power industry, "For Live Working1kV35kVGeneral Technical Specifications for Portable Nuclear PhasersDL/T971-2005》Requirement

comply withIEC61481A2:2004IEC 612431 ed.2:2003standard

structure

operation

1. Basic operations

The receiver and hook detector are both powered on and off by pressing the POWER button. After the detector is turned on, the LED indicator lights up and enters the testing mode. If the LED flashes slowly after turning on, the detector battery is low and needs to be charged, and the LED flashes rapidly during charging. After 15 minutes of startup, the LED continues to flash slowly, indicating that the detector will automatically shut down. At this time, pressing the POWER button will allow the detector to continue working. After the receiver is turned on, the LCD displays, and pressing the up and down arrow keys can adjust the LCD backlight brightness. After the receiver is turned on for 15 minutes, the LCD flashes, indicating that the receiver will automatically shut down. At this time, pressing the POWER button will allow the receiver to continue working.

Press the HOLD key to lock and store data. When locking data, the HOLD symbol indicates that the instrument can store 9999 sets of data.

Press the arrow keys to move the cursor or view data, use the left and right arrow keys to select step values of+1, -1,+10, -10,+100, -100, and press ENTER to confirm viewing the stored data.

Press the ESC key to exit the current directory and return to the measurement interface.

Enter data deletion mode, select "Yes" and press ENTER to confirm the deletion of all stored data. Once the data is deleted, it cannot be recovered. Please proceed with caution.

Nuclear phase distance mode setting: Long press the detector POWER button for 3 seconds to enter the nuclear phase distance mode setting. Short press the detector POWER button to switch between long-distance mode and short distance mode. The long-distance mode LED flashes continuously, while the short distance mode LED flashes slowly. Long press the detector POWER button for 3 seconds to exit the setting mode.

2. Testing

High pressure, extremely dangerous! It must be operated by trained and qualified personnel, and the operator must strictly follow the rules, otherwise there is a risk of electric shock, causing personal injury or casualties.

35kVPlease use non-contact methods for the above bare wire phase detection. The detector should gradually approach the wire, otherwise there is a risk of electric shock and personal injury or death accidents.

Contact nuclear phase: When the bare wire voltage is below 35kV, or when the wire has an insulated outer layer below 110kV, the detector can be hung on the wire to detect the nuclear phase, so that the wire is in Zone A of the detector, and the contact voltage is collected from the metal sheet, as shown in the figure. When the voltage is extremely low, such as below 60V, if the environment is narrow and inconvenient to operate, a thin bare wire can be used to lead out the tested point first, and then the phase can be checked. When leading, attention should be paid to protection to avoid electric shock. During the nuclear phase, the detector automatically adjusts the induction intensity of the electric field, and automatically increases or decreases the signal amplification factor based on the strength of the electric field, making it easier for nuclear phase detection in areas with dense lines.

Non contact nuclear phase: When the voltage of the bare wire is higher than 35kV, the detector gradually approaches the wire (without contacting the wire), and when the detector senses an electric field, it emits a "beep beep beep" beep sound to complete the nuclear phase.

Self verification phase: Before going to the site for phase verification, self verification can be done in the laboratory or office to confirm that the instrument is working properly. First, insert the self calibration line plug into a 220V power socket. Then, contact the two clips of the self calibration line with the voltage acquisition metal pieces of the XY detector, and self verify the phase on the same live wire. The host indicates the same phase. If there is no signal, it is possible that the self calibration line plug is inserted incorrectly. Simply unplug and reinsert it.

Current testing: Hook the X detector of the product with current testing function onto the wire and place the wire in the A zone of the hook type detector to test the current. Position error during current testing: There is no position error in Zone A; The position error in Zone B has increased by approximately 0.2%; The position error in Zone C has increased by approximately 2%.

Multi core cable leakage inspection method: Hook the X detector of the product with current testing function on the cable and inspect along the line. If the receiver changes from displaying a large current to displaying a very small current or no current, this point is the cable leakage point.

During testing, it is strictly prohibited to hook simultaneously2Bare wires can cause2A bare wire short circuit is extremely dangerous.

Hook the live and neutral wires (2 wires) together to measure the leakage current of single-phase electrical equipment.

Hook the grounding wire (1 wire) to measure the leakage current of the grounding wire of the measuring device.

Hook the three-phase four wire (4 wires) together to test the total leakage current.

Hook the main line (1 wire) and measure the current of the main line.

three-phase four-wire(Phase during three-phase load balancing)

Phase relationship

Phase value

Phase relationship

Phase value

Ua-Ub

120°

Ia-Ib

120°

Ub-Uc

120°

Ib-Ic

120°

Uc-Ua

120°

Ic-Ia

120°

Ua-Uc

240°

Ia-Ic

240°

three-phase three-wire(Phase during three-phase load balancing)

Phase relationship

Phase value

Phase relationship

Phase value

Uab-Ucb

300°

Ia-Ic

240°

Uab-Ia

30°

Ucb-Ic

330°

Three phase four wire vector diagram and three phase three wire vector diagram

Battery Management

Timely charge the battery, and charge the battery every 3 months when the instrument is not in use for a long time.

Warning! Testing is prohibited without the battery cover properly closed, otherwise there is a risk.

When replacing the battery, please pay attention to the polarity of the battery, otherwise it may damage the instrument panel.

When the battery voltage is below 3.2V, please charge it in a timely manner. The charging time is about 4 hours.

If replacing the battery, first confirm that the instrument panel is turned off, loosen the screws on the battery cover, open the battery cover, replace it with a new battery, pay attention to the battery specifications and polarity, cover the battery cover, and tighten the screws.

3. Press the POWER button to see if it can turn on normally. If it cannot turn on, please follow step 2 to restart.

If the user is unable to replace the battery, please contact the manufacturer.

Packing List

Hook detector

2a(XTheYeach1a)

receiver

1stage

antenna

3root

Telescopic insulating rod

2root

aluminum case

1a

USBCharger, charging cable

1set

Lithium battery

3a(Inside the instrument panel)

Self study line

1root

User manual, warranty card, certificate of conformity

1set

Our company is not responsible for any other losses caused by use.

The content of this user manual cannot be used as a reason to use the product for special purposes.

Our company reserves the right to modify the content of the user manual. If there are any modifications, no further notice will be given.

1、 Introduction

It is carefully designed and manufactured for high-voltage line phase detection, breaking through the voltage level limitations of traditional phase detectors. It can achieve automatic phase detection from 200V~220kV voltage (such as 400V, 10kV, 35kV, 66kV, 110kV, 220kV) in extremely low voltage lines, without the need to purchase multiple sets of phase detectors according to voltage levels, saving costs, reducing portability, and saving time and speed. For high-voltage line phase detection (when the voltage exceeds 400V), the metal probe hook of the detector can be gradually brought closer to the wire. When an electric field signal is induced, phase detection can be completed without directly contacting the high-voltage wire! When the bare wire voltage exceeds 35kV, non-contact core phase must be used. This nuclear phase analyzer also has functions such as testing phase, frequency, phase sequence, electrical verification, and transformer group determination.

Composed of a host, detector, telescopic insulation rod, monitoring software, USB communication cable, etc., the wireless signal transmission distance is about 30 meters. The host adopts a 3.5-inch true color LCD screen, which can display phase, frequency, phase sequence, and nuclear phase results on the same screen; Vector diagram indication and phase indication, clear and intuitive; It has voice prompts such as "X signal normal, Y signal normal, in-phase, out of phase", making testing simpler and easier.

The monitoring software has online real-time monitoring, historical data query, vector graph indication, and phase indication functions; It has functions such as reading, querying, saving, and printing historical data.

2、 Electrical symbols

III Technical Specifications

Function

High voltage wireless phase, frequency, phase, phase sequence, and electrical testing

Power supply

Host: DC9V, 6 LR6 5th alkaline batteries

Detector: Zinc manganese dry battery 6F22, 9V

Nuclear phase method

Contact type nuclear phase: Bare wires below 35kV or insulated wires below 220kV can contact the core phase of the wire

Non contact core phase: When the bare line voltage exceeds 35kV, non-contact core phase must be used, and the probe can gradually approach the wire

transmission distance

Wireless transmission, with a straight-line transmission distance of about 30 meters

Differential qualitative analysis

Same phase: -25 °~25 °; Heterophase: 95 °~145 ° and 215 °~265 °

Range

Nuclear phase voltage range: 200V~220kV

Test phase: 0.0 °~360.0 °

Test frequency: 45.0Hz to 65.0Hz

Accuracy

Nuclear phase: ≤± 12 °

Frequency: ≤± 2Hz

Resolution

Phase: 0.1 ° Frequency: 0.1Hz

transmission frequency

433MHz、315MHz

LCD

3.5-inch color screen; Display area: 71mm × 53mm

Phase indication

Simultaneous display of phasor diagram and numbers

Power indicator

The detector has a green power indicator light

Work instructions

The nuclear phase detector has sound and light indication function, red double flashing light indication and "beep beep beep beep" buzzing sound

Display speed

2 times per second

data storage

9999 sets (data will not be lost in case of power failure or battery replacement)

LCD backlight

Adjustable brightness to adapt to different usage environments

Auto Shutdown

The instrument panel will automatically shut down after about 5 minutes of startup

battery voltage

When the battery voltage drops to 7.2V ± 0.1V, the low battery voltage symbol is displayed, reminding to replace the battery. At this time, the measured data is also accurate.

rated current

Detector: 30mA max; Host: 150mA max

Instrument quality

Instrument: 950g (including battery); Total weight of packaging and insulation rod: approximately 3.0kg

Instrument size

Host 195mm × 100mm × 45mm; detector 290mm × 250mm × 80mm

Length of insulation rod

Diameter Φ 38mm; Length: 1350mm in reduced state; 5000mm in extended state

insulation test

Two ends of the insulation rod after stretching: AC 220kV/rms

Host and detector: AC3700V/rms (between exposed metal and plastic casing)

external interference

No particularly strong electromagnetic field; No co frequency interference at 433MHz and 315MHz

Working temperature and humidity

-10℃~40℃; Below 80% RH

Storage temperature and humidity

-10℃~60℃; Below 70% RH

Protection level

IP63

Suitable for safety regulations

Requirements of GB13398-92, GB311.1-311.6-8, 3DL408-91 standards and the newly issued national power industry standard "General Technical Conditions for 1kV-35kV Portable Nuclear Phasers Used in Live Working DL/T971-2005"

Compliant with IEC61481-A2; 2004; IEC 61243-1 ed.2:2003 standard

4 structure

1. USB data download interface 2 3.5-inch color LCD screen

3. Host 4. Up, down, left, right arrow keys and MEM control keys

5. Host POWER button (power on/off) 6. Detector hooks (2)

7. Detector probes (2 pieces) 8 X detector

9. Power indicator light 10. Detector POWER button (power on/off)

11. Detector insulation rod connection interface 12. Signal operation indicator light

13. Detector battery bottom cover 14. Y detector

15. Expansion and contraction insulation rod (2 pieces)

Five operation

1. Power on/off of the host

Press the POWER button to turn on the device, and the LCD will display the measurement page. Press the POWER button again to turn off the device. If the LCD continues to flash black after turning on, it may indicate low battery voltage. Please replace the battery. After the instrument is turned on for 5 minutes, the LCD flashes continuously, indicating that the instrument will automatically shut down. The LCD flashes continuously for 30 seconds before automatically shutting down to reduce battery consumption. If the LCD continues to flash, pressing the POWER button will allow the instrument to continue working.

2. Detector power on/off

Press the POWER button to turn on the device, the POWER indicator light will turn on, and the detector will enter testing mode. Then press the POWER button to turn off the device. If the POWER indicator light flashes rapidly or dims after turning on, it may indicate low battery voltage. Please replace the battery. After the detector is turned on for 5 minutes, the POWER indicator light continues to flash, indicating that the detector will automatically shut down. The POWER indicator light flashes continuously for 30 seconds before automatically shutting down to reduce battery consumption. If the POWER indicator light continues to flash, pressing the POWER button will allow the detector to continue working.

3. Data retention

In test mode, press the left arrow key to maintain the LCD display, indicated by the "HOLD" symbol. Press the left arrow key again to unlock the data, return to test mode, and the "HOLD" symbol disappears.

4. Data storage

In test mode, while holding the data with the left arrow key, the instrument automatically numbers and stores the currently held data. This instrument can store 9999 sets of data. If the storage is full and no more data is stored, the memory must be cleared before it can be stored again.

5. Data retrieval

In test mode, press the right arrow key to enter data lookup mode, indicated by the "RD" symbol, and automatically display the stored data of the 0001st group. Press the left and right arrow keys to move the cursor "1, -1, 10, -10, 100, -100" to select the corresponding step size, and press the MEM key to scroll through. Press the left and right arrow keys to move the cursor to the "Exit" position, press the MEM key to exit the search mode, and return to the test mode.

6. Data deletion

In data retrieval mode, press the left and right arrow keys to move the cursor to the "delete" position, press the MEM key to enter data deletion mode, press the left and right arrow keys to move the cursor to "yes" or "no", press the MEM key to perform relevant operations and return to testing mode.

7. Backlight brightness

In any mode, pressing the up and down arrow keys can change the brightness of the LCD backlight. The LCD backlight brightness value is automatically stored, and the instrument panel automatically restores the stored brightness value when powered on.

8. Data upload

Connect the USB communication cable between the computer and the host, turn on the computer, run the software, and you can read the historical data stored in the instrument, upload it to the computer, and manage the data.

The software needs to be installed on Windows XP/2000 system and has functions such as online real-time data, historical query, data saving, vector graph indication, and phase indication; It has functions such as reading, querying, saving, and printing historical data.

9. Self verification

Please perform self calibration before on-site phase verification to confirm that the instrument is functioning properly. Connect the two clips of the self calibration line to the probes of the two detectors, and then plug the self calibration line plug into an AC 220V power socket. Perform self calibration on the same live wire, and the host indicates the same phase. If there is no power, the neutral wire may have been inserted. Simply plug the self calibration line plug back in.

10. Nuclear phase, phase, electrical verification, frequency, and phase sequence testing

Connect the insulation rod and turn on the device. If the communication between the host and the detector is normal, the corresponding indicator light will be on. If the communication is abnormal, the indicator light will not be on. At the same time, the host will voice prompt "X signal normal" and "Y signal normal".

When nucleating, first bring the X detector close to or in contact with any phase line, and then bring the Y detector close to or in contact with other phase lines to be nucleated. When the high voltage nuclear phase occurs, the detector does not need to directly contact the high voltage wire. The detector hook is gradually brought closer to the wire. When an electric field is sensed, the detector will emit a "beep beep beep" prompt sound and the indicator light will continue to flash, completing the electrical verification function. Low voltage phase detection (400V and below), especially for low-voltage phase detection in distribution boxes, please replace the metal probe hook with a metal probe.

When non-contact nuclear phase is used, if the wires of each phase are relatively close to each other, a position far away from other wires should be selected for testing.

The nuclear phase is based on the X detector and displays phase A in a fixed manner. If the phase angle difference between the two detectors is within the range of -25 ° to 25 ° (335 ° to 360 ° is -25 ° to 0 °), the Y detector will detect phase A and classify it as in phase; If the phase angle difference between two detectors is within the range of 95 ° -145 ° or 215 ° -265 °, it is classified as out of phase. At the same time, the host voice prompts "same phase" or "out of phase".

When the phase angle difference is between 95 ° and 145 °, the detection result of the Y detector is phase B, that is, in sequential order; The phase angle difference is between 215 ° and 265 °, and the detection result of the Y detector is phase C, which is the reverse phase sequence.

VI Battery replacement

1) When the battery voltage drops to 7.2V ± 0.1V, the host displays a low battery voltage symbol, and the detector power indicator light flashes rapidly, indicating that the battery is low and needs to be replaced.

2) Press the POWER button to turn off the device, confirm that the instrument panel is in the off state, open the battery cover, replace it with a brand new and qualified battery, pay special attention to the battery specifications and polarity, cover the battery cover, and then turn on the device to confirm whether the replacement is complete.

7 Packing List

host

1 unit

detector

2 units

Probe hook, probe

2 each

Self study line

1 item

USB communication cable

1 item

Monitoring software (CD)

1 sheet

Instrument package

1 piece

Alkaline dry battery (AAA 1.5V)

6 sections

6F22 9V battery

2 pieces

Telescopic insulating rod

2 pieces

User manual, warranty card, certificate of conformity

1 copy