1. Product Introduction
The HW2000 infrared carbon sulfur analyzer is used with GP2000 high-frequency induction combustion, which can determine the content of carbon and sulfur in steel, alloys, non-ferrous metals, rare earth metals, ores, slag, catalysts and other materials quickly and accurately.
This product is the crystallization of the integration of international and domestic advanced technologies. It is a high-tech product integrated optical, mechanical, electrical, computer and analytical technologies. It has many advanced technologies in China. It has the characteristics of wide measurement range, strong anti-interference ability, complete functions, simple operation, and fast and accurate analysis results.
Equipment name: HW2000 high frequency infrared carbon sulfur analyzer
2.application of Equipment
Measure the carbon and sulfur content in steel, alloys, non-ferrous metals, rare earth metals, ores and other solid materials.
Quantity: One
3. The instrument mainly consists of four parts
High frequency induction furnace
Infrared part
Computer part
Electronic balance part
4. Environmental requirements
Ambient temperature: 15-30℃
Ambient humidity: ≤80% (relative humidity)
Power supply: AC220V±5% 50Hz±2%
5. Technical parameter requirements
5.1 measure elements: carbon and sulfur combined measurement
5.2 Analysis methods and requirements: high-frequency heating furnace method, infrared absorption method detection, the analysis time can be adjusted in 20-60 seconds, generally around 35 seconds, the standard sample weight is 0.5 grams, and the sample weight range is 0.1000-1.0000 grams.
5.3 Analysis scope:
C: 0.00001%—10.00000% (scalable to 99.99%)
S: 0.00001%—2.00000% (scalable to 99.99%)
5.4 Analytical accuracy (reproducibility): C: RSD ≤0.5% or 1.0ppm, S: RSD ≤1.0% or 1.0ppm
Long-term accuracy (8 hours, three detections per hour) C: RSD ≤1.0% or 2.0ppm, S: RSD ≤2.0% or 2.0ppm
5.5 Sensitivity (minimum reading): C/S (reading accuracy): 0.01ppm
5.6 Analysis deviation: Carbon meets GB/T7739.9-2007/ISO9556 standard
Sulfur meets GB/T7739.8-2007/ISO4935 standards
5.7 High-frequency furnace power: ≥2.5KW
5.8 Electronic balance weighing accuracy: 0.1mg
5.9 Working cycle: 24 hours continuous operation
6. Circuit system
The circuit system uses large-scale integration, and all large-scale integrated circuit boards which are industrial-grade electronic components and welded mechanically to ensure the stability and reliability of long-term operation. The power supply system has two solid-state power modules. The power supply module has a short circuit protection function, is resistant to current impact, is dust-proof, simple and reliable; the connection uses a shielded flat wire connector, which eliminates the potential for failure caused by poor contact, and improves the reliability of the entire circuit and the connection reliability between lines. The data transmission lines of circuit system and other circuits have professional anti-interference measures to reduce the impact of electromagnetic interference.
7. The whole machine structure
The whole machine use a modular and integrated design, with four independent modules: high-frequency furnace, gas circuit system, circuit system, and infrared detection system. The high-frequency furnace is equipped with professional anti-high-frequency leakage devices, and the entire circuit system has anti-electromagnetic interference devices; avoiding the unstable analysis results caused by high-frequency interference or electromagnetic interference and the impact of high-frequency radiation on the human body.
8. High frequency induction heating furnace
8.1 Heating method: high-frequency induction heating method with combustion control function
8.2 Power: Input power 3.5KW; output power is greater than 2.5KW, air-cooled ceramic power tube is used
8.3 Plate current: up to 500mA, can be set at will, controlled automatically
8.4 Crucible specifications are adopted: diameter Φ23—Φ25 mm
8.5 Automatic cleaning and dust removal design
The ash discharge process is automatically controlled by the computer. Each analysis can eliminate interference from atmospheric background elements and effectively eliminate the impact of moisture in the air on sulfur; each analysis ends with automatic positive pressure pulse to discharge most of the oxide dust generated by combustion out of the machine. Ensure the stability of raw material analysis while reducing equipment maintenance work, providing guarantees for continuous analysis.
9. Infrared detection system
9.1 The infrared detection pool uses platinum micro infrared light source and metal reflector. The molecules of CO2 and SO2 have selective absorption spectrum in the infrared light band. When infrared light of a certain wavelength passes through CO2 or SO2 gas, strong light absorption can be generated.
9.2 The modulation system uses a high-precision stepper motor controlled by a microcontroller
9.3 High-precision infrared pyroelectric detector
9.4 Narrowband filter, high-precision sampling card
10. Gas circuit system
The gas circuit system is stable and reliable, with accurate flow control and good sealing.
11. Computer System
11.1 Brand computer: hard disk capacity 500GB; memory 1GB; 19-inch LCD color displayer;
11.2 Application software that supports Windows XP Chinese operating system
12. Analysis software
12.1 application software in Chinese language is used on the Window operating system, and each sample has 2 or more independent numbers. The database can be retrieved and queried separately according to 2 independent numbers. The result library can be exported to EXECL format for easy use of query, statistics and filing. There are 20 carbon and sulfur channels. Built-in linear calibration software.
12.2 Analysis spare parts: You can set the plate current for heating analysis, and you can set the integration time and accumulated points at will.
12.3 Calibration: 1 point or multi-point correction can print the correction coefficient and correction curve, delete the correction data function, and the analysis results can be converted to the correction function, and the analysis results can be stored automatically, displayed in time, and printed in real time.
12.4 It can display the analytical gas circuit, and realize leakage detection and self-diagnosis functions such as machinery, signals, and output in the analytical gas circuit. It can alarm in time when abnormal situations occur.
12.5 Data processing function: Analytical data statistics processing: The average value, standard deviation, relative standard deviation, etc. can continuously select the data. The analysis data can be transmitted online in a timely manner. The analysis results can be converted into an analysis report at any time. The data output is equipped with an RS-232C interface, which can transmit the analysis data to a network computer.
13. Acceptance and inspection stability (analysis accuracy) and accuracy (linear ratio)
13.1 The accuracy test uses randomly configured standard samples, and conducts 10 continuous analysis immediately after the instrument calibration. The analysis data (1-2 outliers are allowed to be eliminated) calculates the standard deviations of C and S 10 times respectively, and verify the accuracy of their analysis values to meet the above-mentioned solid standard samples analysis accuracy requirements.
13.2 The linear ratio is selected for analysis of three standard samples, high, medium and low, and the linearity is good.