- Phone
-
Address
1607-2, 16th Floor, Building D, Greenland New Metropolis, Jingshan Street, Jinghu District, Wuhu City, Anhui Province
Anhui Zhongwei Environmental Protection Equipment Co., Ltd
1607-2, 16th Floor, Building D, Greenland New Metropolis, Jingshan Street, Jinghu District, Wuhu City, Anhui Province
Hash HQ11D pH/ORP water quality detector from the United States
-Product Overview:
The HQ11D digital pH analyzer can be used with any standard pH IntelliCAL electrode. HQ11D uses a lot of software and technology, which is a very economical measurement method. Calibration data and calibration history can be carried along with each IntelliCAL electrode, allowing operators to switch calibrated electrodes between analyzers. The electrodes should be calibrated in a controllable environment and can be used on-site. Automatic detection of standard procedures and calibration reminders can ensure the accuracy of data. It can store a total of 500 data records by linking each measured sample ID, user ID, and electrode serial number.
-Instrument features:
●multi-purpose machine
A HQd multifunctional water quality detector can be connected to different electrodes. Used for measuring parameters such as pH, ORP, sodium, ammonium, ammonia, fluorine, nitrate, chlorine, conductivity, dissolved oxygen, etc.
●Multiple measurement methods
HQd portable water quality analyzer provides three reading modes, which can achieve measurement of instant reading, indirect reading, and continuous reading.
●Large screen, multi parameter, multi item display
The large dual channel display screen can not only show measurement parameters, but also display auxiliary information such as electrode model, instrument power, measurement date and temperature, sample and user ID.
●Humanized correction guide
The operation interface of HQd portable water quality analyzer is simple and intuitive. It has calibration guidelines and standard procedures for inspection, greatly reducing calibration errors and simplifying the operation process. The calibration status indicator light and calibration reminder ensure that you can obtain the correct calibration results.
●Complete data traceability
The HQd series multifunctional water quality detector can automatically record the electrode serial number, current calibration data, user ID, sample ID, time, and date, and save them in the system's data log. Each measurement data can be associated with sample ID, user ID, electrode serial number, and other data, ensuring complete data traceability and report supervision.
●USB data transfer method
HQd portable water quality analyzer provides USB interface, which can easily transfer data results to USB flash drive and computer.
●Intelligent software system
The upgraded software allows users to customize pH standard solutions, that is, supports users to calibrate pH based on any pH standard solution they have, not just limited to a few fixed pH standard solutions. For conductivity, users can freely choose the reference temperature for temperature compensation, not just at a fixed temperature. For dissolved oxygen, when equipped with conductivity electrodes, the HQd portable water quality analyzer can automatically calibrate the salinity of dissolved oxygen based on the measured salinity, without the need for manual input.
●Shared laboratory and on-site use
The connection between the HQd portable water quality analyzer and the electrode is safe and waterproof. It can be used for both laboratory analysis and on-site analysis. When the light is dim, the instrument screen can emit background light and enlarge the font displayed on the screen. In addition, users can also choose a sturdy and durable on-site toolbox, which makes on-site measurements extremely convenient.
-Technical indicators:
|
HQ11D (portable) HQ411d (desktop) |
HQ14d (portable) |
HQ30d (portable) HQ430d (desktop) |
HQ40d (portable) HQ440d (desktop) |
|
| Electrode connection port | 1(pH) | 1 (Conductivity) | 1 (pH, conductivity, O2) ion selective electrode | 2 (pH, conductivity, O2, Ion selective electrode |
| Dissolved oxygen (LDO) | ● | ● | ||
| range | 0.00-20.0mg/L; 0-200% saturation | |||
| resolution | 0.01 or 0.1 mg/L; 0.1% saturation | |||
| accuracy | ± 1% range | |||
| pressure compensation | automatic | automatic | ||
| pH | ● | ● | ● | |
| range | 0-14 | 0-14 | 0-14 | |
| Resolution (optional) | 0.1/0.01/0.001 | 0.1/0.01/0.001 | 0.1/0.01/0.001 | |
| accuracy | ±0.002 | ±0.002 | ±0.002 | |
| temperature compensation | automatic | automatic | automatic | |
| ORP | ● | ● | ● | |
| range | ±1500mV | ±1500mV | ±1500mV | |
| resolution | 0.1mV | 0.1mV | 0.1mV | |
| accuracy | ±0.1mV | ±0.1mV | ±0.1mV | |
| Ionic concentration (ISE) | ● | ● | ||
| range | Depends on ISE electrode | |||
| Resolution (optional) | 0.1/0.01/0.001 | |||
| accuracy | ±0.1mV | |||
| temperature | ● | ● | ● | ● |
| range | –10~+110℃ | –10~+110℃ | –10~+110℃ | –10~+110℃ |
| resolution | 0.1℃ | 0.1℃ | 0.1℃ | 0.1℃ |
| accuracy | ±0.3℃ | ±0.3℃ | ±0.3℃ | ±0.3℃ |
| conductivity | ● | ● | ● | |
| range | 0.01μS/cm -200mS/cm | 0.01μS/cm-400mS/cm | ||
| accuracy | ±0.5%(1μS/cm -200mS/cm) | ±0.5%(1μS/cm -400mS/cm) | ||
| temperature compensation |
Nonlinear (natural water meets DIN 38404 and EN ISO 7888) Nonlinear (NaCl), linear correlation coefficient [value]%/℃, no compensation |
|||
| resistivity | ● | ● | ● | |
| range | 2.5Ωcm - 49MΩcm | 2.5Ωcm - 49MΩcm | 2.5Ωcm - 49MΩcm | |
| accuracy | ±0.5% | ±0.5% | ±0.5% | |
| TDS | ● | ● | ● | |
| range | 0.0-50.0mg/L | 0.0-50.0mg/L | 0.0-50.0mg/L | |
| accuracy | ± 0.5 (within the range) | |||
| salinity | ● | ● | ● | |
| range | 0-42 (g/kg, ‰, without units) | |||
| resolution | 0.01ppt | 0.01ppt | 0.01ppt | |
| accuracy | ± 0.1mg/L, when less than 8mg/L | ± 0.1mg/L, when less than 8mg/L | ± 0.1mg/L, when less than 8mg/L | |
| Automatic reading | ● | ● | ● | ● |
|
auto-correction Automatic recognition of buffer solution |
pH:s; HQ30/40D |
pH: IUPAC 1.679; 4.005; 7.000; 10.012 DIN 1.09; 4.65; 9.23 Color coded 4, 7, 10 |
||
|
Conductivity: Demal (1D; 0.1D; 0.01D) Molar(0.1M;0.01M;0.001M) NaCl (0.05%;25μS/cm;1000μS/cm;18mS/cm) User defined; Standard seawater |
||||
|
Correction point Calibration and validation standards reminder |
Up to 4 points | 1 point |
PH up to 4 points Conductivity at 1 point O2 1 point |
PH up to 4 points Conductivity at 1 point O2 1 point ISE has a maximum of 5 points |
| Analyzer interface |
A waterproof USB interface that can be used for printers, computers, keyboards, and USB flash drives (Except for HQ40d, other models require optional selection) |
|||
| password protection | ● | ● | ● | ● |
| data management | GLP Data Management Method | |||
| data storage | 500 readings; Can manually or automatically store data | |||
|
Sample ID and Operator ID |
Arabic numerals: up to 12 characters; 12 sample names and 20 user names Automatically record sample number (0-999) |
|||
| Measurement Mode | Manual, intermittent, continuous; Analysis method editable | |||
| display | Backlit graphic display; 240 × 160 pixels; Automatic shutdown power-saving mode; Can display time and date | |||
| power supply | 115V-250V or 4 AA batteries | |||
| protection level | IP67 | |||
| size, weight | 95 × 197 × 36mm (H × W × L), 323g (without battery) | |||
-Kit packaging:
HQ11D host: including: HQ11D host+4 No. 5 batteries+operation manual, etc
Package I: including: HQ11D host+PHC101 standard, PH gel electrode, cable length of 1m
Package II: including: HQ11D host+PHC101 standard, PH gel electrode, cable length of 3m
Package 3: Includes: HQ11D host+PHC101 rugged model, PH electrode, 5-meter cable length
Package 4: Includes: HQ11D host+PHC301 standard model, PH liquid filled electrode, cable length of 1 meter
Package 5: Includes: HQ11D host+PHC301 standard model, PH liquid filled electrode, cable length of 3 meters
Hash HQ11D pH/ORP water quality detector from the United States