Welcome Customer !

Membership

Help

Beidouxing Industrial Chemistry Research Institute, Haidian District, Beijing
Custom manufacturer

Main Products:

instrumentb2b>Products

Beidouxing Industrial Chemistry Research Institute, Haidian District, Beijing

  • E-mail

    674338455@qq.com

  • Phone

    18611900152

  • Address

    Institute of Physics, Chinese Academy of Sciences, Zhongguancun, Haidian District, Beijing

Contact Now

Handheld hydrogen analyzer Beidou Star

NegotiableUpdate on 06/26
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The Beidouxing handheld sensor is ingeniously designed to be similar to general instruments, directly used for grinding bottles, or connected to pipelines with pipe threads for temporary continuous detection. Handheld hydrogen analyzer supplied by Beidou Star manufacturer

Product Details

HBD5gas-H2 Handheld Hydrogen Analyzer

____Equipped with selective sensors, while testing temperature for temperature correction


  • Built in microcontroller microcomputer

  • At any temperature, simply insert the sample and immediately read out the electrochemical gas parameters and temperature values

  • 24 sets of data records, can be set to automatic or manual recording

  • Readable/printable records

  • Can be used for grinding bottles or temporary continuous analysis of pipelines

  • RS232/485 duplex interface, capable of online sampling with microcomputers

  • Zero adjustment of inert gas, calibration of standard samples or substitutes

  • All operation keyboard settings, window prompts

The H-BD5 tester is an intelligent system with a built-in single-chip microcomputer and an extremely advanced hardware system design. All data can be saved in case of power failure. Each instrument provides * analysis/testing techniques, maximizing the solidification of professional methods. Capable of supporting fieldbus and RS232/485 communication interface. The BD5 tester enables most instruments to provide full range testing, eliminating the hassle of range selection.

The Beidouxing handheld sensor is ingeniously designed to be similar to general instruments, directly used for grinding bottles, or connected to pipelines with pipe threads for temporary continuous detection.

The H-BD5 universal analyzer can be used for any electrochemical electrode sensor (other products can also be used), or other sensors on Beidou satellite. The system is equipped with digital databases for multiple gases. Each channel can be calibrated with dual sample DKA, KS single sample calibration, and inert gas zeroing. The main channel must be calibrated with the main parameter standard sample, and other channels can be expanded to test the concentration of other gases with cross reactions.

The main channel can be set to a storage mode for recording the reaction process. You don't have to worry about losing calibration table data when using multiple single probes. Just type the calibration number on the keyboard.

The H-BD5GS universal tester can replace parameters or probes.

Usage Application

Laboratory or on-site gas testing

The electrode can be inserted into the ZG1 'tube thread for continuous detection, or it can be inserted into a grinding bottle

Gas research

Industrial analysis

leak detection

Handheld hydrogen analyzer Beidou Star

Technical Specifications for Analyzer

Display: 2x16 LCD

Sensor response time:<10s, Max<60s

Environmental temperature: -30 ℃~70 ℃ (processor)

Environmental humidity: 0% to 90% R (processor)

Power supply: 9V rechargeable battery or DC 9V power supply

Continuous battery operation:>10 hours/voltage drop alarm

Processor size: 98W × 180H × 35D

Analyzer resolution: 24 bits (FS=+/-1280mV)

Common instrument specifications and models


H-BD5-2610H2-R?

pBD5-2610-H2-R4%

Professional grade analyzer

pBD5-2610H2-MR

Professional grade analyzer

TECHNICAL INDEX


Range: 0-2000ppm/1%/4%

Resolution: 15/20/100 ppm

Repetition accuracy: 1% R

Accuracy:<2% FS

Operating temperature: -20~+50 ° C

Usage humidity: 15~90% RH

Sample pressure: 90~120kPa

Annual drift:<5%

Sensor lifespan: 2 years

Heat up time T90:<150s

Range: 0-4%,~100.0%

Resolution: 20/100 ppm

Repeatability accuracy:<1% reading

Accuracy:<2% FS

Operating temperature: -20~+50 ° C

Usage humidity: 15~90% RH

Sample pressure: 90~120kPa

Annual drift:<5%

Sensor lifespan: 2 years

Heat up time T90:<150s

Range: 0-4%,~100.0%

Resolution: 100 ppm

Repetition accuracy:

<1% reading (<4%);

<2% reading (>4%);

Accuracy:

<2% reading (<4%);

<5% reading (>4%);

Operating temperature: -20~+50 ° C

Usage humidity: 15~90% RH

Sample pressure: 90~120kPa

Annual drift:<5%

Sensor lifespan: 2 years

Heat up time T90:<150s

component

One HBD5gs main tester

1 H2 sensor

1 temperature probe

1 rechargeable battery

One charger

1 aluminum alloy instrument box

One BD5 main analyzer

1 H2 sensor

1 temperature probe

1 humidity probe

1 set of accessories for high concentration analysis system

1 rechargeable battery

One charger

1 sampling gun

1 aluminum alloy instrument box

One BD5 main analyzer

1 H2 sensor

1 temperature probe

1 humidity probe

1 set of accessories for high concentration analysis system

1 rechargeable battery

One charger

1 sampling gun

1 aluminum alloy instrument box

Recommended applications

Hydrogen leak detection

Trace hydrogen detection and analysis

Hydrogen leak detection

Trace hydrogen detection and analysis

Industrial analysis

Hydrogen leak detection

Trace hydrogen detection and analysis

Industrial analysis





Handheld hydrogen analyzer Beidou Star

Components and selection information Configuration

Electrochemical sensor transmitter

name

name

Range

Repetitive accuracy

specifications

Probe lifespan/month

Conditions of Use

hydrogen

H2

2-1,000/2000ppm

≤ ±2%

2610

24

-20°C to +50°C;

15 to 90% non condensing;

Atmospheric pressure ± 10%

hydrogen

H2

10-10,000/20,000ppm

≤±2%

2610

24

-20°C to +50°C;

15 to 90% non condensing;

Atmospheric pressure ± 10%

hydrogen

H2

10-50,000ppm

≤ ±2%

2610

24

-20°C to +50°C;

15 to 90% non condensing;

Atmospheric pressure ± 10%

  • Other special gases not listed need to be discussed and ordered specifically.

  • Pay attention to the on-site conditions. The lower limit of temperature for general electrochemical sensors is -10 ° C. The upper limit is 40 or 50 ° C.

For more gas sensor parameters, please refer to:

List of complete components:

unit

specifications

quantity

describe


HBD5 main analyzer


1 unit

Select one host

The basic system includes

temperature probe


1 unit


The basic system includes

Humidity probe


1 unit


select

Pressure probe


1 unit


select

Other probes



According to the ordering requirements

Select according to the tested gas

Probe seat

GasBar-A


Used for air environment diffusion sampling.

The basic system includes

Probe seat

GasBar-T


Used for air environment diffusion sampling or pipe thread connection

select

Rechargeable Battery

9V

1 piece


The basic system includes

Backup battery


1 piece

2510 sensor or choose when working outdoors for a long time

select

charger

DC12V

1 piece


The basic system includes

Aluminum alloy instrument box


1 piece


The basic system includes