HBD5gas-H2 Handheld Hydrogen Analyzer
____Equipped with selective sensors, while testing temperature for temperature correction
Built in microcontroller microcomputer
At any temperature, simply insert the sample and immediately read out the electrochemical gas parameters and temperature values
24 sets of data records, can be set to automatic or manual recording
Readable/printable records
Can be used for grinding bottles or temporary continuous analysis of pipelines
RS232/485 duplex interface, capable of online sampling with microcomputers
Zero adjustment of inert gas, calibration of standard samples or substitutes
All operation keyboard settings, window prompts

The H-BD5 tester is an intelligent system with a built-in single-chip microcomputer and an extremely advanced hardware system design. All data can be saved in case of power failure. Each instrument provides * analysis/testing techniques, maximizing the solidification of professional methods. Capable of supporting fieldbus and RS232/485 communication interface. The BD5 tester enables most instruments to provide full range testing, eliminating the hassle of range selection.
The Beidouxing handheld sensor is ingeniously designed to be similar to general instruments, directly used for grinding bottles, or connected to pipelines with pipe threads for temporary continuous detection.
The H-BD5 universal analyzer can be used for any electrochemical electrode sensor (other products can also be used), or other sensors on Beidou satellite. The system is equipped with digital databases for multiple gases. Each channel can be calibrated with dual sample DKA, KS single sample calibration, and inert gas zeroing. The main channel must be calibrated with the main parameter standard sample, and other channels can be expanded to test the concentration of other gases with cross reactions.
The main channel can be set to a storage mode for recording the reaction process. You don't have to worry about losing calibration table data when using multiple single probes. Just type the calibration number on the keyboard.
The H-BD5GS universal tester can replace parameters or probes.
Laboratory or on-site gas testing
The electrode can be inserted into the ZG1 'tube thread for continuous detection, or it can be inserted into a grinding bottle
Gas research
Industrial analysis
leak detection
Display: 2x16 LCD
Sensor response time:<10s, Max<60s
Environmental temperature: -30 ℃~70 ℃ (processor)
Environmental humidity: 0% to 90% R (processor)
Power supply: 9V rechargeable battery or DC 9V power supply
Continuous battery operation:>10 hours/voltage drop alarm
Processor size: 98W × 180H × 35D
Analyzer resolution: 24 bits (FS=+/-1280mV)
H-BD5-2610H2-R? |
pBD5-2610-H2-R4% Professional grade analyzer |
pBD5-2610H2-MR Professional grade analyzer |
|
|
TECHNICAL INDEX |
Range: 0-2000ppm/1%/4% Resolution: 15/20/100 ppm Repetition accuracy: 1% R Accuracy:<2% FS Operating temperature: -20~+50 ° C Usage humidity: 15~90% RH Sample pressure: 90~120kPa Annual drift:<5% Sensor lifespan: 2 years Heat up time T90:<150s |
Range: 0-4%,~100.0% Resolution: 20/100 ppm Repeatability accuracy:<1% reading Accuracy:<2% FS Operating temperature: -20~+50 ° C Usage humidity: 15~90% RH Sample pressure: 90~120kPa Annual drift:<5% Sensor lifespan: 2 years Heat up time T90:<150s |
Range: 0-4%,~100.0% Resolution: 100 ppm Repetition accuracy: <1% reading (<4%); <2% reading (>4%); Accuracy: <2% reading (<4%); <5% reading (>4%); Operating temperature: -20~+50 ° C Usage humidity: 15~90% RH Sample pressure: 90~120kPa Annual drift:<5% Sensor lifespan: 2 years Heat up time T90:<150s |
component |
One HBD5gs main tester 1 H2 sensor 1 temperature probe 1 rechargeable battery One charger 1 aluminum alloy instrument box |
One BD5 main analyzer 1 H2 sensor 1 temperature probe 1 humidity probe 1 set of accessories for high concentration analysis system 1 rechargeable battery One charger 1 sampling gun 1 aluminum alloy instrument box |
One BD5 main analyzer 1 H2 sensor 1 temperature probe 1 humidity probe 1 set of accessories for high concentration analysis system 1 rechargeable battery One charger 1 sampling gun 1 aluminum alloy instrument box |
Recommended applications |
Hydrogen leak detection Trace hydrogen detection and analysis |
Hydrogen leak detection Trace hydrogen detection and analysis Industrial analysis |
Hydrogen leak detection Trace hydrogen detection and analysis Industrial analysis |
Electrochemical sensor transmitter
name |
name |
Range |
Repetitive accuracy |
specifications |
Probe lifespan/month |
Conditions of Use |
hydrogen |
H2 |
2-1,000/2000ppm |
≤ ±2% |
2610 |
24 |
-20°C to +50°C; 15 to 90% non condensing; Atmospheric pressure ± 10% |
hydrogen |
H2 |
10-10,000/20,000ppm |
≤±2% |
2610 |
24 |
-20°C to +50°C; 15 to 90% non condensing; Atmospheric pressure ± 10% |
hydrogen |
H2 |
10-50,000ppm |
≤ ±2% |
2610 |
24 |
-20°C to +50°C; 15 to 90% non condensing; Atmospheric pressure ± 10% |
Other special gases not listed need to be discussed and ordered specifically.
Pay attention to the on-site conditions. The lower limit of temperature for general electrochemical sensors is -10 ° C. The upper limit is 40 or 50 ° C.
For more gas sensor parameters, please refer to:
List of complete components:
unit |
specifications |
quantity |
describe |
|
HBD5 main analyzer |
1 unit |
Select one host |
The basic system includes |
|
temperature probe |
1 unit |
The basic system includes |
||
Humidity probe |
1 unit |
select |
||
Pressure probe |
1 unit |
select |
||
Other probes |
According to the ordering requirements |
Select according to the tested gas |
||
Probe seat |
GasBar-A |
Used for air environment diffusion sampling. |
The basic system includes |
|
Probe seat |
GasBar-T |
Used for air environment diffusion sampling or pipe thread connection |
select |
|
Rechargeable Battery |
9V |
1 piece |
The basic system includes |
|
Backup battery |
1 piece |
2510 sensor or choose when working outdoors for a long time |
select |
|
charger |
DC12V |
1 piece |
The basic system includes |
|
Aluminum alloy instrument box |
1 piece |
The basic system includes |