The EST-101A series high-precision gas detector is a portable handheld gas concentration measuring instrument with a replaceable probe design. It is divided into two parts: the main unit and the probe. Users only need to replace the corresponding probe to change the measuring gas. It adopts a high-precision circuit design and uses imported sensor chips as the core. After being developed and calibrated by Wanyi Technology, signal amplification, calibration, and strict testing, it is sent out of the factory.
The EST-101A multi probe gas detector mainly monitors gas types:
|
EST-101A series sensor probe selection table |
||||||
|
Sensor probe model |
Detect gas |
Standard range ppm |
Display resolution in ppm |
sensitivity ppm |
accuracy |
response time (T90) |
|
EST-101A-CH2O-1 |
formaldehyde |
0-1 |
0.001 |
0.01 |
±5%F.S. |
<50S |
|
EST-101A-CH2O-10 |
formaldehyde |
0-10 |
0.01 |
0.01 |
±5%F.S. |
<50S |
|
EST-101A-VOC-5 |
Volatile organic gases |
0-5 |
0.001 |
0.01 |
±5%F.S. |
<50S |
|
EST-101A-O3-20 |
ozone |
0-20 |
0.001 |
0.015 |
±5%F.S. |
<60S |
|
EST-101A-O3-100 |
ozone |
0-100 |
0.01 |
0.06 |
±5%F.S. |
<60S |
|
EST-101A-O3-200 |
ozone |
0-200 |
0.1 |
0.1 |
±5%F.S. |
<60S |
|
EST-101A-NH3-50 |
ammonia |
0-50 |
0.1 |
0.1 |
±5%F.S. |
<60S |
|
EST-101A-SO2-20 |
sulfur dioxide |
0-100 |
0.001 |
0.005 |
±5%F.S. |
<15S |
|
EST-101A-NO-20 |
nitric oxide |
0-20 |
0.001 |
0.015 |
±5%F.S. |
<25S |
|
EST-101A-NO2-20 |
nitrogen dioxide |
0-20 |
0.001 |
0.015 |
±5%F.S. |
<60S |
|
EST-101A-CL2-20 |
chlorine |
0-20 |
0.01 |
0.02 |
±5%F.S. |
<90S |
|
EST-101A-C2H4-10 |
ethylene |
0-10 |
0.01 |
0.1 |
±5%F.S. |
<60S |
|
EST-101A-H2S-200 |
hydrogen sulfide |
0-200 |
0.001 |
0.001 |
±5%F.S. |
<60S |
|
EST-101A-H2-5000 |
hydrogen |
0-5000 |
1 |
1 |
±5%F.S. |
<45S |
|
EST-101A-H2O2-100 |
hydrogen peroxide |
0-100 |
0.1 |
0.2 |
±5%F.S. |
<60S |
|
EST-101A-CO-500 |
carbon monoxide |
0-500 |
0.1 |
1 |
±5%F.S. |
<40S |
|
EST-101A-CO-1000 |
carbon monoxide |
0-1000 |
0.001 |
0.005 |
±5%F.S. |
<40S |
|
EST-101A-CO2-2000 |
Carbon dioxide (infrared method) |
0-2000 |
50 |
50 |
±5%F.S. |
<60S |
|
EST-101A-CO2-5000 |
Carbon dioxide (infrared method) |
400-5000 |
50 |
50 |
±5%F.S. |
<60S |
|
EST-101A-TVOC-20 |
Total volatile organic gases (PID photoionization) |
0-20 |
0.001 |
0.005 |
±3%F.S. |
<20S |
|
EST-101A-TVOC-200 |
Total volatile organic gases (PID photoionization) |
0-200 |
0.001 |
0.025 |
±3%F.S. |
<20S |
|
EST-101A-TVOC-2000 |
Total volatile organic gases (PID photoionization) |
0-2000 |
0.01 |
0.05 |
±3%F.S. |
<20S |
|
EST-101A-SF6-1000 |
Sulfur hexafluoride (infrared method) |
0-1000 |
1 |
1 |
±3%F.S. |
<20S |
|
EST-101A-SF6-2000 |
Sulfur hexafluoride (infrared method) |
0-2000 |
1 |
1 |
±3%F.S. |
<20S |
|
Note: The above is a standard gas selection, and the company supports customization. If you need to test the range of other gas types, please contact our phone number |
||||||
The instrument design and production shall comply with relevant national standards:
GB/T18883-2002 "Indoor Air Quality Standards" GB3095-1996 "Environmental Air Quality Standards"
GB50325-2010 "Code for Indoor Environmental Pollution Control of Civil Building Engineering"
GB50325-2001 Code for Indoor Environmental Pollution Control of Civil Building Engineering
GB12358-2006 "General Technical Requirements for Workplace Gas Detection and Alarm Devices" Industrial Standard
EU Directive 2002/231/CE Taiwan Indoor Air Quality Standard
EMC electromagnetic compatibility related testing standards, European standard EN55022, American standard FCC
(Note: The calibration cap can be connected to a gas sampling pump for use)
EST-101A Multi Probe Series Gas Detector Features:
|
Detection object |
optional |
External power supply |
5VDC/500mA |
|
detection |
Diffusion type |
Type |
Lithium Ion Battery |
|
Detection Principle |
electrochemistry/infrared/PID/optional |
battery voltage |
3.7V(Charging restrictions4.2V) |
|
operation temperature |
-20℃-45℃ |
Battery capacity |
1600mAh |
|
Working humidity |
0-85%RH |
ShutDown Current |
<0.1mA |
|
Display mode |
LCDLCD screen |
Power on current |
<10mA |
|
compressed air |
860-1060hpa |
alarm current |
<50mA |
|
Warm-up time |
120second |
protection grade |
dustproof |
|
response time |
T90<50S |
Alarm method |
2Level sound and light alarm |
|
service life |
Based on sensors |
alarm error |
≤±10%alarm set value |
|
zero drift |
≤±2%FS/6Month |
Data Storage |
not have |
|
Span drift |
≤±5%FS/6Month |
signal output |
not have |
|
repeatability |
≤±2% |
External dimensions |
120*60*35mm |
|
Whole machine weight |
≤250g(Including battery) |
||
Product Supporting List
1. EST-101 Gas Detector Host Unit 1
2. EST-101A sensor probe (variety and quantity customized according to customer needs) several
3. Universal 5V power adapter ... one
4. User Manual ... 1 book
5. Factory Inspection Report ... 1 copy
6. Calibration cap/protective cap (one each)
7. Portable suitcase One... one