PRODUCT INFORMATION
measuring range:LR:0 to 250 mg/L(ppm)CaCO3;
MR:200 to 500 mg/L(ppm)CaCO3;
HR:400 to 750 mg/L(ppm)CaCO3
Adopting innovative optical system design, it has excellent accuracy, repeatability, and measurement time required,HannauniqueCAL Check ™The function allows for performance validation and calibration of instruments using NIST traceable standards, with built-in reaction timers to ensure consistency between sample measurements and user results, and good laboratory practices(GLP)Display the date and time of the last user calibration, battery status indicator light, and automatic shutdown settings.
reminder:NEWHI97735Total hardness tester,Total hardness【CaCO3】Convert readings to French degrees [º]F】Readings, UK degrees [º]E】Readings or German degrees [º]dH】Readings to meet your needs for different units of measurement results.
TECHNICAL INDEX
| technical specifications |
HI96735total hardness |
| measuring range |
LR【P1】:0 to 250 mg/L(ppm)CaCO3 MR【P2】:200 to 500 mg/L(ppm)CaCO3 HR【P3】:400 to 750 mg/L(ppm)CaCO3 |
| resolution |
LR:1 mg/L( ≤ 100 mg/L ); 5 mg/L ( > 100 mg/L);MR:/HR:5 mg/L |
| accuracy@25°C (77°F) |
LR:reading±4% ± 5 mg/L ;MR:reading±3% ± 7 mg/L;HR:reading±2% ± 10 mg/L |
| Units |
1France degree(°FH) = 10.0 mg/L CaCO3;1German degree(°DH)= 17.8 mg/L CaCO3;1UK degree(°EH)= 14.3mg/L CaCO3 |
| optical system |
narrow band interference filter,silicon photocellTungsten lamp @ 466 nm |
| Method standards |
refer toEPARecommended methods130.1 |
| Power Mode |
1 x 9V battery |
| Automatic shutdown |
In measurement mode, measurement mode10In minutes, or in calibration mode, it will automatically shut down after one hour of no use |
| application environment |
0 to 50 °C(32 to 122°F ); RH-max95%(No condensation) |
| Dimension |
Host size:192 x 104 x 69 mm (7.6 x 4.1 x 2.7”)、Host weight:320 g (11.3 oz.) |
| Exclusive attachments |
HI731333Glass cuvette(HI731331+HI731335)Specification: Outer diameter24.6Mm (inner diameter)22mm),4Set/Group |
|
HI93735-0 Customized Full Range Total Hardness Reagent Prediction Times100order |
|
|
|
HI93735-00 Customized Low Range [LR] Total Hardness Reagent Prediction Times 100order |
|
|
HI93735-01 Customized Medium Range [MR] Total Hardness Reagent Prediction Times 100order |
|
|
HI93735-02 Customized High Range [HR] Total Hardness Reagent Prediction Times 100order |
|
HI96735-11 total hardnessNISTMeasurement curve calibration group, standard value@25ºC:0 and 150 ± 5 mg/L [LR], 350 ± 7 mg/L [MR], 520 ± 10 mg/L [HR] |
Standard configuration